Shanghai Ziyi Automation Instrument Co., Ltd
Home>Products>Electrical contact bimetal thermometer
Electrical contact bimetal thermometer
Electrical contact bimetal thermometer
Product details

ZY electric contact bimetallic thermometer
Application:
Electrical contact bimetal thermometerApplied to the production site for automatic temperature control and alarm. Directly measure the temperature of body, steam, and gas media within the range of -80 to 500 ℃ in various production processes.
characteristic
·On site temperature display, intuitive and convenient;
·Equipped with automatic power-off and alarm functions;
·Safe and reliable, with a long service life;
·Multiple structural forms can meet different requirements.
Working principle
Electrical contact bimetal thermometerIt is to use temperature changes to drive contact changes, and when it is disconnected from the upper and lower limit contacts, the relay in the circuit is activated, thereby automatically controlling and alarming.
Main technical parameters
·Product execution standards: JB/T8803-1998 GB3836-83
·Scale dial nominal diameter: 100
·Accuracy level: (1.0),1.5
·Thermal response time: ≤ 40S
·Protection level: IP55
·Normal working atmospheric conditions: temperature -25~+55 ℃, relative humidity ≤ 85%
·Setpoint error: The set point error should not exceed 1.5 times the basic error limit.
·Switching error: The switching error should not exceed 1.5 times the basic error limit.
·Switching repeatability: The limit range of switching repeatability should not exceed 1/2 of the absolute value of the basic error limit.
Electrical parameters
Rated power VA
Maximum working voltage V
Maximum allowable current
10
220 a.c
0.7A
24 d.c
Selection code
Model naming method
WSS
Bimetal thermometer
X Electrical contact structure
Nominal diameter of dial -4/5 Φ100/ф150
Dial form 0 Axial (straight)
1 Radial (angular)
8 Wanxiang (adjustable angle type)
Installation fixed form 0 No fixed device
1 Movable external thread
2 Movable internal thread
3 Fixed thread
4 Flange
5 Ferrule thread
6 Card sleeve flange
Protection form M Upper and lower limits
N Double upper limit
P Double lower limit
remarks:
Selection notice: Please provide the model, dial diameter, accuracy level, installation and fixing form, temperature measurement range, protective tube material, length or insertion depth.
Selection example: Universal type, dial diameter of Φ 100, temperature measurement range of 0-400 ℃, 1.5 levels, movable external thread M27 × 2, length 450mm
WSSX-481, 0-400 ℃, L=450, M27 × 2, Class 1.5
Model and specifications
model
Measuring range
accuracy class
Protective tube material
specifications
Install fixed devices
WSSX-400/500
-80~+40
-40~+80
0~50
0~100
0~150
0~200
0~300
0~400
0~500
1.5
1Cr18Ni9Ti
304
316
316L
Ha Shi C-276
75
100
150
200
300
400
500
750
1000
No fixed device
WSSX-401/501
WSSX-480/580
WSSX-401/501
Movable external thread
WSSX-411/511
WSSX-481/581
WSSX-402/502
Movable internal thread
WSSX-412/512
WSSX-482/583
WSSX-403/503
Fixed thread
WSSX-413/513
WSSX-483/583
WSSX-404/504
Flange
WSSX-414/514
WSSX-484/584
WSSX-405/585
Ferrule thread
WSSX-415/515
WSSX-485/585
WSSX-406/506
Card sleeve flange
WSSX-416/516
WSSX-486/586
Note: Special forms can be ordered according to the agreement.




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code