Electromagnetic flowmeter (sanitary type)
Electromagnetic flowmeter (sanitary type) Click count: 78 Time of listing: 2020-01-01 National service hotline: I want to inquire Product description
Product details
Electromagnetic flowmeter (sanitary type)

Click count: 78

Listing time: January 1, 2020

National Service Hotline:

I want to inquire about the price

product description

The TM-LDE series electromagnetic flowmeter is designed to meet the hygiene requirements of the food industry by using sanitary lining materials and clamp connection processing technology for the traditional flange connected pipeline electromagnetic flowmeter. It meets the hygiene requirements of the food industry. At the same time, the sanitary electromagnetic flowmeter adopts a stainless steel shell and stainless steel clamp connection, which facilitates the quick disassembly and cleaning of the electromagnetic flowmeter, making the medium less likely to be contaminated during use and effectively preventing the accumulation of residual measurement fluid in the measuring tube. It can be applied in the production and manufacturing process of food such as mineral water, soy sauce, jam, beer, juice, rice wine, milk, as well as hygiene, chemical and other fields.
1、 Characteristics:
1. The sensor adopts a new type of sanitary lining material to prevent the accumulation of residual measuring media in the measuring tube.
2. The sensor adopts a quick connection scheme, and the electromagnetic flowmeter is easy to disassemble, maintain, and clean.
3. The converter adopts a 16 bit embedded microprocessor for signal processing, which has the characteristics of high integration, fast operation speed, high calculation accuracy, fully digital signal processing, strong anti-interference ability, and reliable measurement.
4. The flowmeter is a bidirectional measurement system equipped with three integrators: forward total, reverse total, and differential total; It can display positive and negative flow rates and has multiple outputs: current, pulse, digital communication, and HART protocol.
2、 Technical parameters
1. Caliber: DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100
2. Accuracy: Level 0.5; Level 1.0
3. Temperature of the tested medium: T < 120 ℃
4. Environmental temperature:- 20~+45℃
5. Relative humidity: 5%~95%
6. Rated pressure: PN1.0
7. Flow velocity range: 0.3~12m/s
8. Conductivity:> 5μs/cm
9. Electrode: 316L
10. Lining: PTFE
11. Body material: stainless steel
12. Power supply: AC220V ± 10%? 50Hz±5%; DC24V
13. Output signal: 4~20mA; RS232 RS485; HART protocol; Pulse output
14. Protection level: IP65
15. Explosion proof level: EXdiiBT4~6 ?? EXdiiCT4~6
16. Product category: Integrated pipeline; Pipeline split type
3、 Caliber and flow range

Caliber (mm)

Flow range (m3/h)

Chuck size (mm)

Caliber (mm)

Flow range (m3/h)

Chuck size (mm)

DN15

0.4~6

50.5

DN50

4~60

77.5

DN20

0.6~12

50.5

DN65

6~120

91

DN25

1.0~16

50.5

DN80

10~160

119

DN32

1.6~25

50.5

DN100

16~250

145

DN40

2.5~40

64




5、 Product selection

model

caliber

Sanitary electromagnetic flowmeter

TM-LDE

15~100



code

Installation form


Y

Integrated

F

split type


code

Converter model

ZA

rotundity

ZB

Square (only applicable to split type)


code

Power supply form

AC

(AC) 220V AC 50Hz (90~245V AC 50Hz)

DC

(DC) 24V DC (20-36V DC)

LD

Lithium battery power supply (without signal output)


code

Output Signal (Multiple Choice)


I

4~20mA


f

Frequency 1KHz


Rs

Serial communication (485)


H

Equipped with HART protocol


C

control output



Code name

Explosion proof requirements

N

No explosion-proof

EX

Explosion proof (only applicable to split type)


code

medium temperature

T1

≤65℃

T2

≤120℃


code

Lining material

PTFE

PTFE


code

Electrode material

316L

stainless steel




Previous: Dual rotor flowmeter

Next article: Electromagnetic flowmeter (GPRS)

Related products

  • 便携式 精密数字压力计
    Portable precision digital pressure gauge
  • GNS-JYY-3过程信号校验仪
    GNS-JYY-3 Process Signal Verification Instrument
  • 热电偶、热电阻自动校验装置
    Automatic calibration device for thermocouple and thermistor
  • GNS-JYY-T热工仪表校验装置
    GNS-JYY-T Thermal Instrument Calibration Device

news

  • Analysis of the advantages and disadvantages of plug-in vortex flowmeter[2020-01-01]
  • The setting of circuit parameters for measuring different media using vortex flowmeter[2020-01-01]
  • Analysis of the influence of the stabilizing system of the regulating water flow standard device on the instrument coefficient of the vortex flowmeter[2020-01-01]
  • Requirements for installation environment of vortex flowmeter[2020-01-01]
  • Manufacturer of vortex flowmeter briefly describes the problems encountered during operation[2020-01-01]
  • Analysis of the advantages of intelligent orifice flowmeter in practical measurement[2020-01-01]
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!