1. It has the characteristics of sensitive action, simple connection, large flow rate, small volume, and high adjustment accuracy. The control accuracy and performance are significantly improved compared to the DKZ type.
2. Suitable for situations with strict requirements for leakage, low pressure difference before and after the valve, and certain viscosity. Widely used in industries such as power, metallurgy, chemical, petroleum, environmental protection, light industry, equipment, etc.
3. The electric actuator is an electronic integrated structure with a servo amplifier inside. By inputting control signals (4-20mADC or 1-5VDC) and power supply, the valve opening can be controlled to adjust working parameters such as pressure, flow rate, liquid level, and temperature.
1、 Product Details
Product model: ZDLN
Product Name:Electric dual seat electronic regulating valve
1.It has the characteristics of sensitive action, simple connection, large flow rate, small volume, and high adjustment accuracy. The control accuracy and performance are significantly improved compared to the DKZ type.
2. Suitable for situations with strict requirements for leakage, low pressure difference before and after the valve, and certain viscosity. Widely used in industries such as power, metallurgy, chemical, petroleum, environmental protection, light industry, equipment, etc.
3. The electric actuator is an electronic integrated structure with a servo amplifier inside. By inputting control signals (4-20mADC or 1-5VDC) and power supply, the valve opening can be controlled to adjust working parameters such as pressure, flow rate, liquid level, and temperature.
IIElectric dual seat electronic low-temperature regulating valveOutline dimension table
Nominal diameter DN (mm)
|
D
|
DN
|
H1
|
-100℃
|
-200℃
|
-250℃
|
Weight Kg
|
H2
|
H
|
H2
|
H
|
H2
|
H
|
25
|
225
|
270(290)
|
102
|
500
|
1010
|
700
|
1210
|
900
|
1410
|
41
|
32
|
225
|
300(310)
|
105
|
500
|
1013
|
700
|
1213
|
900
|
1413
|
44
|
40
|
255
|
310(340)
|
127
|
500
|
1063
|
700
|
1263
|
900
|
1463
|
62
|
50
|
255
|
340(370)
|
132
|
500
|
1068
|
700
|
1268
|
900
|
1468
|
67
|
65
|
255
|
380(410)
|
171
|
600
|
1292
|
800
|
1492
|
1000
|
1692
|
100
|
80
|
255
|
410(440)
|
188
|
600
|
1301
|
800
|
1501
|
1000
|
1701
|
112
|
100
|
255
|
470(500)
|
200
|
600
|
1305
|
800
|
1505
|
1000
|
1705
|
143
|
125
|
310
|
550(590)
|
250
|
700
|
1592
|
900
|
1792
|
1100
|
1992
|
229
|
150
|
310
|
600(640)
|
260
|
700
|
1592
|
900
|
1792
|
1100
|
1992
|
296
|
200
|
310
|
720(760)
|
300
|
700
|
1509
|
900
|
1792
|
1100
|
1992
|
471
|
Note: The numbers in parentheses represent PN64 dimensions.
IIIZDLN electronic double seat at normal and medium temperaturesOutline dimension table
Nominal diameter DN (mm)
|
L
|
H1
|
H
|
D
|
Weight Kg
|
PN(MPa)
|
normal temperature
|
Moderate temperature
|
PN1.6MPa
|
PN4.0-6.4MPa
|
1.6
|
4.0
|
6.4
|
normal temperature
|
Moderate temperature
|
25
|
185
|
190
|
200
|
120
|
560
|
710
|
225
|
26
|
30
|
33
|
32
|
200
|
210
|
210
|
120
|
563
|
714
|
225
|
28
|
31
|
34
|
40
|
220
|
230
|
235
|
140
|
618
|
769
|
255
|
38
|
47
|
51
|
50
|
250
|
255
|
265
|
145
|
623
|
774
|
255
|
41
|
51
|
55
|
65
|
275
|
285
|
295
|
190
|
799
|
962
|
255
|
61
|
80
|
88
|
80
|
300
|
310
|
320
|
210
|
812
|
975
|
255
|
77
|
100
|
110
|
100
|
350
|
355
|
370
|
220
|
824
|
987
|
255
|
96
|
120
|
131
|
125
|
410
|
425
|
440
|
270
|
1066
|
1278
|
310
|
160
|
195
|
244
|
150
|
450
|
460
|
475
|
280
|
1078
|
1290
|
310
|
205
|
249
|
269
|
200
|
550
|
560
|
570
|
320
|
1116
|
1328
|
310
|
275
|
402
|
435
|
250
|
640
|
660
|
670
|
450
|
1257
|
1497
|
310
|
485
|
605
|
665
|
300
|
720
|
735
|
750
|
465
|
1302
|
1543
|
310
|
635
|
755
|
825
|
4Electric dual seat electronic regulating valveAllowable pressure difference
nominal
orifice
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
Allowable pressure difference
PN(MPa)
|
<<nominal pressure>>
|
4.0
|
3.4
|
5Electric dual seat electronic regulating valveMain technical parameters of the institution
Nominal diameter DN (mm)
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
Rated flow coefficient (KV)
|
10
|
16
|
25
|
40
|
63
|
100
|
160
|
250
|
400
|
630
|
1000
|
1600
|
Nominal pressure PN (MPa)
|
1.6, 4.0, 6.4 (normal temperature), 4.0, 6.4 (medium temperature), 0.6, 4.0, 6.4 (low temperature)
|
Travel L (mm)
|
16
|
25
|
40
|
60
|
100
|
Action speed mm/s
|
2.1
|
3.5
|
1.7
|
2.8
|
2.0
|
Equipped with electric actuator model
|
3810LSA-20
3810LXA-20
|
3810LSB-30
3810LXB-20
|
3810LSB-50
3810LXB-50
|
3810LSC-65
|
3810LSC-99
|
Traffic characteristics
|
Straight line, equal percentage
|
Medium temperature (℃)
|
-20~=+200 (normal temperature), -20~+450 (medium temperature), -250~-60 (low temperature)
|
Flange size
|
Cast iron flange according to JB78-59, cast steel flange according to JB79-59
|
Flange model
|
According to JB77-59, cast iron flanges are smooth, cast steel flanges are concave, and low-temperature flanges are mortise and tenon groove
|
Valve body material
|
Nominal pressure MPa
|
0.6
|
Temperature resistance -250~-60 ℃, ZG1Cr18Ni9Ti (-196 ℃) \ CF8M (-250 ℃)
|
1.6
|
Room temperature 1250-200 ℃ WCB、CF8、CF8M
|
4.0
|
Room temperature -20~200 ℃ WCB、ZG1Cr18Ni9Ti、
|
6.4
|
Medium temperature -4 to -450 ℃ WCB、ZG1Cr18Ni9Ti、CF8、CF8M
|
Low temperature -250~-60 ℃, ZG1Cr18Ni9Ti (-196 ℃), CF8M (-250 ℃)
|
VIElectric dual seat electronic regulating valveMain technical parameters of the executing agency
model
|
Rated output force N
|
Speed mm/s
|
Technical Parameter
|
3810LSA-20
3810LXA-20
|
2000
|
2.1
|
Power Supply: AC220V 50Hz
Input signal: DC4-20mA
DC1-5V
(Shielded wire for signal line)
Output opening signal: DC4-20Ma
Upper cover protection level: equivalent to Lp55
Explosion proof sign: ExdllBT4
|
3810LSB-30
3810LXB-20
|
3000
|
3.5
|
3810LSB-50
3810LXB-50
|
5000
|
1.7
|
3810LSC-65
|
6500
|
2.8
|
3810LSC-99
|
10000
|
2.0
|
[Ordering Notice]
When placing an order, please fill out the "Specification Book" or specify the following in detail:
1. Product model 2, nominal diameter 3, rated flow coefficient KV 4, flow characteristics 5, valve body material 6, low-temperature valve needs to indicate the operating temperature and the length of the connecting pipe 7, pressure before and after the valve 8, medium type and temperature range 9, whether there is a space heater inside the electric actuator