1. Equipment structure and functional description
Equipment Composition
Equipment Overview
This manual is19 Inch rack type erbium-doped fiber power amplifier(EDFA-BA)Instructions for using the device. This should be setBackup is mainly used in certain long-distance and high-speed communication scenarios to increase the fiber optic power of the line.
Equipment Composition
The front panel of erbium-doped fiber power amplifier equipment is shown in the figure1 As shown, the rear panel is as shown in the figure2 As shown.
Front panel schematic diagram
picture1 Schematic diagram of the front panel of the equipment
On the front panel, from left to right, they are: product name, power switch, status indicator light, input light port, and output lightMouth. The optical port adoptsFC/PCForm.
Rear panel schematic diagram
picture2 Schematic diagram of the rear panel of the device
On the back panel from left to right are: switch alarm interface, Ethernet interfaceRS-232Interface, power inputAFuse tube, power input interface, power inputBFuse tube and grounding terminal.
Panel Description
optical interface
InputAs an input port for signal light, it receives signal light from the transmitting device,OutputThe signal output terminal of the amplifier.
power interface
The power input interface adoptsP4The socket interface form and pin definitions are as follows:
picture 3 Power connectionopeningshowmeaningpicture
outside 1(From left to right, they areA1、A2、B1、B2On the far right is the grounding terminal):
Serial Number |
name |
describe |
A1 |
0 |
Positive pole of power input |
A2 |
-48V |
Negative pole of power input |
B1 |
0 |
Positive pole of power input |
B2 |
-48V |
Negative pole of power input |
Note: Supports dual power input,A1、A2For a set of power sources;B1、B2For another set of power sources.
pilot lamp
The status indicator lights are described as follows:
POWER INPUT OUTPUT PUMP TEMP
picture 4 faceBoard fingershowlampshowintention
Instructions:outside2:
Serial Number |
name |
describe |
1 |
POWER |
Power indicator light, green light when normal |
2 |
INPUT |
When the input optical power is lower than the set input power threshold, the red light will turn on. Normally, it does not light up. |
3 |
OUTPUT |
When the output optical power is lower than the set output power threshold, the red light will turn on. Normally, it does not light up. |
4 |
PUMP |
When the bias current of the pump laser is abnormal, the red light will turn on. Normally, it does not light up. |
5 |
TEMP |
When the internal temperature of the device exceeds the operating temperature range, the red light will turn on. Normally, it does not light up. |
RS232 communication interface
RS-232The interface adoptsRJ-45The form and pin definitions are as follows: Table3:
Baud rate115200 bps
8 bits transmit
No checksum
Ethernet communication interface
pass throughUDPProtocol for network monitoring.
HouseKeeping Switch alarm interface(Disconnect normally, connect in case of alarm)
HouseKeepingThe interface adoptsRJ-45The form and pin definitions are as follows: Table4:
2. Main performance indicators and specifications
Mechanical dimensions
L × W × H=483mm×200mm×44mm
Note: Provided19、21 Two sizes of hanging ears.
working conditions
Environmental temperature:0~+50℃
Relative humidity:5~85%RH(+25℃) Atmospheric pressure:70~106Kpa
Environmental air: No corrosive or solvent gases, no dust, and no strong electromagnetic field interference in the vicinity. Power supply conditions:- 48Vdirect-current
Voltage range:- 40V~- 57V
Main performance indicators
outside5:
parameter |
minimum value |
Typical values |
Maximum value |
unit |
wavelength |
1530 |
1565 |
nm |
|
Input optical power |
-6 |
+3 |
dBm |
|
Saturated output optical power1 |
10 |
22 |
dBm |
|
Noise index(Pin=0dBm) |
- |
5.5 |
dB |
|
polarization dependent gain |
- |
- |
0.3 |
dB |
working voltage |
-48 |
VDC |
||
power consumption |
20 |
W |
explain:1Corresponding output power based on different models.
3. Equipment installation and activation
Unpacking inspection
Open the packaging box and compare with the table6Please confirm that the listed materials are in the packaging box. If there are any defects, please contact us promptly.outside6 List of main materials for supply:
Installation steps
After removing the device, place it steadily on a horizontal desktop or fix it on a rack;
Secure the nuts of the two sets of screws that fix the equipment onto the ear holes on both sides of the rack, and then thread the bolts through the ear holes of the equipmentThe ear holes of the rack are finally riveted together with the nuts;
Connect the blue wires of the power cord separately-48V(negative electrode)The black wire is connected to 0V(positive electrode)Above, the yellow green line represents the protected areaConnecting line.
Place the power switch in“ON”Status: Observe whether the indicator lights on the panel are correct. At this point Powe(rAlarm(red light)Should be in a glowing state;
green light)andInput
Remove the protective cap on the optical port and input the optical signal. If the connection is correct and there is a signal on the line, at this time, the panel willOnly power indicator light(green light)Illuminate, all others are in the off state.
4. Common problems and solutions
1After turning on, the power does not turn on: Please check if the type of power module used is consistent with the type of power supply you are using, and check the positive and negative polarity of the power supply. The power supply used should comply with the power specifications in this manual.
2Input alarm indicator light on: Turn off the power and check if the optical power at the optical input port is within the input range of the erbium-doped fiber power amplifier. If it still cannot be solved, please confirm whether the input and output optical ports of the device are connected in reverse. Is the wavelength of the optical signal within the operating wavelength range of the device.
3Temperature alarm: Please confirm if the ambient temperature around the device is too high.
4Output alarm, pump alarm: When this alarm occurs, please turn off the device and contact us promptly.