Experimental Ultra Pure Water Machine UPHW
The laboratory ultrapure water machine UPHW has a delicate appearance and uses distilled water RO pure water deionized water as the source water to pr
Product details
Functional Features
1. Laboratory ultra pure water machine UPHW, LCD liquid crystal display with Chinese display; Equipped with human-machine dialogue function;
2. Automatic shutdown protection function for water tank shortage
3. The online monitoring function of the conductivity of the incoming water quality (the factory equipment has a value of 20 μ s/cm, and the machine does not start when it exceeds this value to avoid mistakenly entering unqualified "pure water" and causing damage and failure of the UP purification column);
4. UP ultra pure water resistivity/water temperature online monitoring function;
5. UP ultra pure water quality control water intake setting function (1-18 M Ω. cm);
6. UP ultrapure water quantitative water intake setting function (1-99 liters);
7. Clock setting function (year/month/day/hour/minute);
8. Language setting function (Chinese/English)
9. UP ultra pure water system cycle time setting function (1 second to 180 seconds);
10. Search for historical data records——
⑴ Time of each water intake (year/month/day/hour/minute)
⑵ Previous water intake volume (liters)
⑶ Water quality of each water intake (conductivity/resistivity)
⑷ Cumulative total water intake (liters)
⑸ Records of all consumables alarm replacements
11. RS422 computer monitoring software system (optional at an additional cost)
12. Mini printer outputs printing data (optional at an additional cost)
13. Adopting UP-PLC intelligent control system for one click operation

(Figure 1)

(Figure 2)

(Figure 3)
(Figure 1) Reservation for quantitative water intake setting
(Figure 2) Ultra pure water resistivity/water temperature, online monitoring of water intake
(Figure 3) System automatic/manual cycle setting
Compulsory circulation of ultrapure water ensures that the quality of the ultrapure water taken by customers remains constant above the user's rated standards.
Eliminating the waste of unqualified ultrapure water during the waiting process for water intake.
The efficiency of resin exchange in the purification package can be fully utilized, and the yield of ultra pure water can be increased by 30% compared to general process designs.
TECHNICAL INDEX
Ordering Instructions
1. Users of this model should bring their own pure water tank or distilled water tank
2. This model can be used as a terminal ultrapure water device for the laboratory building's pure water system
3. The TOC of the source water should be less than 50ppb
1. Laboratory ultra pure water machine UPHW, LCD liquid crystal display with Chinese display; Equipped with human-machine dialogue function;
2. Automatic shutdown protection function for water tank shortage
3. The online monitoring function of the conductivity of the incoming water quality (the factory equipment has a value of 20 μ s/cm, and the machine does not start when it exceeds this value to avoid mistakenly entering unqualified "pure water" and causing damage and failure of the UP purification column);
4. UP ultra pure water resistivity/water temperature online monitoring function;
5. UP ultra pure water quality control water intake setting function (1-18 M Ω. cm);
6. UP ultrapure water quantitative water intake setting function (1-99 liters);
7. Clock setting function (year/month/day/hour/minute);
8. Language setting function (Chinese/English)
9. UP ultra pure water system cycle time setting function (1 second to 180 seconds);
10. Search for historical data records——
⑴ Time of each water intake (year/month/day/hour/minute)
⑵ Previous water intake volume (liters)
⑶ Water quality of each water intake (conductivity/resistivity)
⑷ Cumulative total water intake (liters)
⑸ Records of all consumables alarm replacements
11. RS422 computer monitoring software system (optional at an additional cost)
12. Mini printer outputs printing data (optional at an additional cost)
13. Adopting UP-PLC intelligent control system for one click operation


(Figure 1)

(Figure 2)

(Figure 3)
(Figure 1) Reservation for quantitative water intake setting
(Figure 2) Ultra pure water resistivity/water temperature, online monitoring of water intake
(Figure 3) System automatic/manual cycle setting
Compulsory circulation of ultrapure water ensures that the quality of the ultrapure water taken by customers remains constant above the user's rated standards.
Eliminating the waste of unqualified ultrapure water during the waiting process for water intake.
The efficiency of resin exchange in the purification package can be fully utilized, and the yield of ultra pure water can be increased by 30% compared to general process designs.
TECHNICAL INDEX
model | UPHW-I-90T microanalysis type | UPHW-II-90T Ultrafiltration heat removal prototype |
UPHW-III-90T Ultra low organic matter type |
UPHW-IV-90T Super Ji Combination Type |
Inlet water source | Distilled water/deionized water/RO water (conductivity<20uS/cm) | Distilled water/RO water (conductivity<20uS/cm, TOC<50ppb) | ||
Water production capacity | 1.0-1.5 liters per minute | 0.6-1.0 liters per minute | 1.0-1.5 liters per minute | 0.6-1.0 liters per minute |
Water production resistivity | 18.2MΩ.cm | |||
TOC | ≤20ppb | ≤5ppb | ||
Heat source (endotoxin) | —— | ≤0.001EU/ml | —— | ≤0.001EU/ml |
Host size (mm) | L×W×H:270×350×565 | |||
Working power supply | AC220V/50HZ (power: 30-60W) | |||
Weight (kg) | 20-30kg | |||
Terminal microfilter | 0.22 μ m (imported) |
Ordering Instructions
1. Users of this model should bring their own pure water tank or distilled water tank
2. This model can be used as a terminal ultrapure water device for the laboratory building's pure water system
3. The TOC of the source water should be less than 50ppb