Measure the length in3040mmWe highly recommend this series of products under high-speed and high vibration environmental conditions. Three zero reference points are available for selection: every50mmThere is a zero reference pointIo; Zero reference points can be selectedIoDistance encoded zero reference pointIoThis series of reading heads (rulers) have a built-in socket connected to a cable, making it easy for users to install and remove.
Technical Parameter |
Incremental linear grating ruler |
||||
model |
GX/GOX/GSX |
GY/GOY/GSY |
GW/GOW/GSW |
GP/GOP/GSP |
|
accuracy |
±5μm(±0.0002″) ±3μm(±0.00012″) |
||||
resolution |
1μm (0.00004″) |
0.5μm (0.00002″) |
0.1μm (0.000004″) |
accessible0.1μm (0.000004″) |
|
Zero reference pointIo |
GX,GY,GWandGP:From the middle to both ends,every50mmone GOX,GOY,GOWandGOP:distance-coded GSX,GSY,GSWandGSP:Zero reference points can be selected |
||||
output signal |
|
|
|||
Output signal cycle“T” |
4μm |
2μm |
0.4μm |
20μm |
|
Maximum cable length |
50m(165ft) |
150m(495ft) |
|||
Technical Parameter |
Absolute linear grating ruler |
||||
model |
GA |
GAF |
GAM |
GAP |
|
accuracy |
±5μm(±0.0002″) ±3μm(±0.00012″) |
||||
resolution |
1μm (0.00004″) |
0.05μm (0.000002″) |
|||
Zero reference pointIo |
- |
||||
absolute position measurement |
Continuous binary code optical reading |
||||
output signal |
|
- |
- |
- |
|
Output signal cycle“T” |
20μm |
||||
Maximum cable length |
150m(495ft) |
||||
UBSinterface |
pass throughRS-485giveUSBconverter(optional) |
Size unit: mm(inches) |
Installation method |