Sichuan Fagao Electric Co., Ltd
Home>Products>FCI200 series universal magnetic flux vector control frequency converter
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18080478713
  • Address
    Building 2, No. 166 Wuxing Fourth Road, Wuhou District, Chengdu City
Contact Now
FCI200 series universal magnetic flux vector control frequency converter
FCI200 series universal magnetic flux vector control frequency converter
Product details

FCI200 series universal magnetic flux vector control frequency converter


Product Introduction

The FCI200 series frequency converter adopts modular design, which can flexibly meet customers' personalized and industry specific needs through extended design while meeting their general needs, representing the trend of future industry applications of frequency converters. Built in universal expansion interface and powerful speed and torque control, practical process closed-loop control, simple PLC, flexible input and output terminals, pulse frequency setting, power outage and shutdown parameter storage selection, frequency setting channel bundled with operation command channel, main and auxiliary setting control, swing frequency control, speed tracking, encoder disconnection monitoring, automatic fault recovery, built-in braking unit, 28 types of fault monitoring, up to 16 segments of multi-stage speed control, parameter copying and other functions. Meeting the requirements of various complex high-precision transmissions while providing highly integrated integrated solutions for equipment manufacturing customers has great value in reducing system costs and improving system reliability.


Product Features

0.5HZ 180% rated starting torque, beyond your imagination

◆ Three control modes; V/F、 Magnetic flux vector and torque control can be freely selected

The carrier frequency of 1K~15k can be automatically adjusted according to the load characteristics

◆ Simple PLC completes up to 16 frequency logic segments for automatic control, with four acceleration and deceleration times to choose from

◆ "Excavator" feature, automatic torque control during operation

◆ Multiple triangular wave frequency controls, swing frequency function can be dedicated to occasions such as wire drawing, textile, chemical fiber, etc. that require lateral and winding functions

Users can easily extend the keyboard using standard Ethernet cables themselves

10 types of auxiliary frequency sources can flexibly achieve auxiliary frequency fine-tuning and frequency synthesis

The maximum frequency of the weak magnetic control algorithm can exceed twice the fundamental frequency of the motor during operation

The droop control feature can enable load balancing and distribution when multiple frequency converters drive the same load

Accurate speed control precision, open-loop control ≤± 0.5% (rated synchronous speed), closed-loop control ≤± 0.2% (rated synchronous speed)

The FCI202 series has a built-in universal expansion interface that can expand I/O cards, PG cards, Profibus DP cards, and industry-specific module expansion cards


Technical Parameter

project specifications
Main control performance

Maximum frequency

400Hz

Carrier Frequency

1K~15kHZ; Automatically adjust carrier frequency based on load characteristics

Input frequency resolution

Digital setting: 0.01Hz

Simulation setting: maximum frequency x 0.1%

control mode

Open-loop flux vector control 1, open-loop flux vector control 2, V/F control

Starting torque

G-type machine: 0.5Hz/180% (open-loop magnetic flux vector control)

P-type machine: 0.5Hz/120% (open-loop magnetic flux vector control)

speed range

1: 200 (open-loop magnetic flux vector control)

Steady speed accuracy

(Speed control accuracy)

Open loop magnetic flux vector control: ≤± 0.5% (rated synchronous speed)

Stability of speed control

Open loop magnetic flux vector control: ≤± 0.3% (rated synchronous speed)

Torque response

≤ 40ms (open-loop magnetic flux vector control)

Overload capacity

G-type machine: 150% rated current for 60 seconds; 180% rated current for 5 seconds

P-type machine: 120% rated current for 60 seconds; 150% rated current for 5 seconds

Torque boost

Automatic torque boost; Manual torque increased by 0.1% to 30.0%

V/F curve

Three ways: straight line type; Multi-point type; Square V/F curve

Acceleration and deceleration curve

Linear or S-shaped acceleration and deceleration methods; Four types of acceleration and deceleration times; Acceleration and deceleration time range: 0.0s to 3000.0s

dc braking

DC braking frequency: 0.0Hz to maximum frequency, braking time: 0.0 to 36.0 seconds, braking action current value: 0.0% to 100.0%

inching control

Jogging frequency range: 0.00Hz to 50.00Hz; Jogging acceleration and deceleration time: 0.0s to 3000.0s

Simple PLC, multi-stage operation

Up to 16 speed segments can be achieved through built-in PLC or control terminals

Built in PID

Convenient implementation of process control closed-loop control system

Automatic Voltage Regulation (AVR)

When the voltage of the power grid changes, it can automatically maintain a constant output voltage

Torque Limitation and Control

The "excavator" feature automatically limits the torque during operation to prevent frequent overcurrent tripping; Closed loop vector mode can achieve torque control

Personalized features

Power on peripheral device safety self check

Can perform safety checks on peripheral devices such as grounding and short circuits when powered on

Common DC bus function

Can achieve the function of multiple frequency converters sharing the DC bus

JOG key

Programmable key: Function selection for forward and reverse operation/jog operation

Textile swing frequency control

Multiple triangular wave frequency control functions

Quick current limiting function

Built in fast current limiting algorithm reduces the probability of overcurrent reporting in the frequency converter and improves the overall anti-interference ability of the machine

timing control

Timer control function: Set time range from 0h to 65535h

Standardization of keyboard extension cords

Customers can extend the keyboard using standard Ethernet cables on their own

run

Run Command Channel

Three channels: operation panel given, control terminal given, and serial communication port given. Can be switched in multiple ways

Frequency source

There are a total of 10 frequency sources: digital given, analog voltage given, analog current given, pulse given, and serial port given. Can be switched in multiple ways

Auxiliary frequency source

10 types of auxiliary frequency sources. Flexible implementation of auxiliary frequency fine-tuning and frequency synthesis

Input terminal

Five digital input terminals, compatible with active PNP or NPN input methods

Two analog input terminals, of which AI1 can only be used as a voltage input, and AI2 can be used as a voltage or current input. If you need to expand the input and output terminal functions, please choose the FCI202 series

Output terminal

A digital output terminal (bipolar output)

Two relay output terminals

An analog output terminal that can be selected from 0/4mA to 20mA or 0/2V to 10V, capable of outputting physical quantities such as set frequency, output frequency, and speed

Display and keyboard operation

led display

Display parameters

lcd display

Optional, Chinese/English prompts for operation content

Parameter copying

Using a dedicated keyboard for parameter copying can achieve fast copying of parameters

Key locking and function selection

Implement partial or complete locking of keys, define the scope of action of some keys to prevent accidental operation

Protection and selection of accessories

Protection function

Short circuit detection of power on motor, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, overload protection, etc

Select accessories

LCD operation panel, brake components, etc

environment

Place of use

Indoor, not exposed to direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, dripping or salt, etc

altitude

Below 1000 meters

ambient temperature

-10 ℃~+40 ℃ (ambient temperature is between 40 ℃~50 ℃, please reduce the rating for use)

humidity

Less than 95% RH, no condensation of water droplets

vibrate

Less than 5.9 meters per second2(0.6g)

storage temperature

-20℃~+60℃

pollution degree

2

Product standards

Product compliance with safety standards

IEC61800-5-1:2007

The product complies with EMC standards

IEC61800-3:2005


If you need detailed information or the latest product information, please send your name, contact information, and company name tosale@foago.comOr call -8002 to request, thank you for your attention and support to our company!

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!