Hangzhou Jingfei Technology Co., Ltd
Home>Products>FLA4000 Miniature Fiber Optic Spectrometer
FLA4000 Miniature Fiber Optic Spectrometer
FLA4000 Miniature Fiber Optic Spectrometer
Product details
Product model:
FLA4000 seriesMiniature Fiber Optic Spectrometer
Analyze the universal type
Product Introduction:
The FLA4000 series miniature fiber optic spectrometer has a compact and small appearance, is plug and play, easy to operate, and has advanced electronic systems and powerful detectors, as well as high-speed data acquisition circuit systems. Its features include a 16 bit A/D converter with automatic reset function (enhanced electronic dark current correction), a 4K deep FIFO system, and a USB2.0 high-speed data transmission interface, which can quickly upload the data collected by the instrument to a PC for data processing and display; By combining various optical platform components, light sources, and sampling fibers, unique testing systems can be built for thousands of absorption, reflection, and emission measurement applications.
FLA4000 seriesMiniature Fiber Optic SpectrometerCan be connected to a computer through USB 2.0 interface. The characteristic data of each spectrometer is stored in its memory; Using professional testing software, easy to read data and supporting heat exchange. Having a rich secondary development platform and related example development software.

Technical specifications:

detector Detector model Toshiba TCD1304DG Linear Array CCD
Detecting spectral range 200~1100nm
pixel 3648 pixels
pixel size 8μm×200mμm
Pixel trap depth ~100000 electrons
Optical platform Design F/4, Symmetrical cross Czernmy Turner optical path
focal length 70mm input; 90mm output
Incident aperture 50 μ m slit (5-200 μ m optional)
Fiber optic connector SMA905
Spectral characteristics Wavelength Range
200nm~400nm; 200nm~800nm;
350nm~850nm; 400nm~1100nm.
Conventional testing half width 0.8nm FWHM (customizable upon request)
Signal to noise ratio 300:1 (full signal)
A/D 16 bits
Dark noise 12RMS count value
dynamic range 1300:1 single detection
Integral time 1 millisecond to 60 seconds
Stray light <0.1% at 600nm; 0.1% at 435nm
Correction of linearity >99.8%
Electronic characteristics power waste
160mA@5 VDC
Data transmission speed Full scan to memory, USB 2.0 takes 2ms
computer
operating system
USB port: Windows 2000/XP
Serial port Hardware supports Android, Linux, Windows, and Wince systems
Interface USB 2.0 or RS232
computer interface
USB2.0 @ 480Mbps,
Rs232 @9600bps

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!