Guangzhou Xisen Automation Control Equipment Co., Ltd
Home>Products>FLRN series electromagnetic thermal energy meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18022306695
  • Address
    Building C5- Xisen Building, Gaosha Industrial Park, 105 National Highway, Panyu District, Guangzhou City
Contact Now
FLRN series electromagnetic thermal energy meter
1. Optional photoelectric button, no need to open the cover operation, making it faster to modify setting parameters on site. 2. 10mm tempered glass,
Product details

产品描述.jpg

FLRN电磁式热能表-厂家

西森电磁式热能表

图片关键词

图片关键词

1. Using a 16 bit microcontroller for data calculation, platinum thermistor for temperature measurement, and electromagnetic flowmeter for flow measurement, the measurement accuracy is high and the application is stableReliable and with excellent performance.

2. The measurement accuracy is not affected by changes in parameters such as viscosity, density, pressure, conductivity, and fluid distribution of the heat carrying fluid.
3. The instrument has no resistance components, no pressure damage, and is not affected by poor water quality.
4. The measurement flow range is wide, and the flow velocity can be set arbitrarily within the range of 1m/s to 10m/s.
5. The large screen LCD displays in Chinese with clear readings.
6. The thermal energy meter displays accumulated heat, accumulated flow rate, instantaneous heat, instantaneous flow rate, inlet temperature, outlet temperature, temperature difference and other data simultaneously
Capable of querying and displaying parameters such as flow rate and power outage records.

7. Adopting the enthalpy correction method with random temperature changes to ensure accurate measurement at different water temperatures.
8. It has a unified DC signal and frequency signal output function, and this function can switch between heat and flow parameters.
9. It has batch processing (quantitative output), equivalent pulse output, and key controlled direct reset function.
10. Equipped with RS-485 (RS-232, M-BUS, and HART optional) digital communication output for convenient remote communication.
11. It has password protection function, and those without a password cannot modify working parameters.

电磁式热能表显示
Electromagnetic thermal energy meter is a type of measuring heat transfer in thermal conversion systemsA measuring instrument for the heat released by a fluid. It uses high precisionHigh reliability electromagnetic flowmeter is used for flow measurement, adopting high-precision technologyPlatinum thermistor with high temperature and stability is used for temperature measurement to measure the thermal energyThe table has excellent measurement performance.
Widely applicable to civilian useResidential communities, office buildings, and enterprises and institutions provide centralized heating and heating servicesMeasurement of heat such as air conditioning.

技术参数.jpg

Converter section

communication

RS485 (RS232, M-BUS, HART, etc. optional)

Housing material

aluminum alloy

Sensor section

Normal operating temperature

class a

Housing material

stainless steel

temperature resolution

0.01℃

nominal pressure

1.6MPa

Optional temperature measurement range

-30℃~180℃

Electrode material

316L

Temperature difference measurement range

1℃~90℃

Lining material

Chloroprene rubber (CR), polytetrafluoroethylene (PTFE)

Polyurethane (PU)Soluble polytetrafluoroethylene (PFA)

Perfluoroethylene propylene (F46)

power supply

220VAC(110VAC~245VAC)、24VDC

structural style

Integrated and split type

power consumption

<20W (when paired with sensors)

protection grade

Integrated IP65 rating; Split IP67, optional IP68

measurement accuracy

±1.0%perhaps±2.0%(Matching accuracy)

medium temperature

Integrated:-20℃~+100℃;Split type:-20℃~+100℃

protection grade

IP65

Connection method

Flange type, threaded type, clamp type, clamping type

Maximum flow reading (m3)

999999999 (nine digits)

Temperature sensor section

Maximum reading of heat (kWh, MWh)

999999999 (nine digits)

sensor type

PT1000

thermal unit

KJ, MJ, GJ, kWh, MWh optional

Installation method

protective sleeve

Analog Output

(4~20) mA DC/600 Ω load resistance

(switchable between heat and flow parameters)

Temperature measurement range

-50℃~200℃

pulse output

Maximum frequency 5000Hz, pulse width:0.1ms~999.9ms

(switchable between heat and flow parameters)

Wire length

0.6m~15m

技术参数.jpg

caliber

(mm)

V=0.1m/s Qmax=m3/h

V=0.3m/s Qmax=m3/h

V=0.5m/s Qmax=m3/h

V=1 m/s Qmax=m3/h

V=2 m/s Qmax=m3/h

V=3 m/s Qmax=m3/h

V=5 m/s Qmax=m3/h

V=7 m/s Qmax=m3/h

V=10 m/s Qmax=m3/h

6

0.01

0.03

0.05

0.1018

0.2036

0.3054

0.5089

0.7125

1.018

8

0.018

0.054

0.09048

0.1810

0.3619

0.5429

0.9048

1.2667

1.8096

10

0.028

0.08

0.14137

0.2827

0.5655

0.8482

1.4137

1.96

2.8274

15

0.064

0.19

0.31809

0.6362

1.2723

1.9085

3.1809

4.45

6.3617

20

0.113

0.34

0.56549

1.1310

2.2619

3.3929

5.6549

7.91

11.3097

25

0.238

0.53

0.884

2.3821

4.7642

7.1463

11.9105

12.39

23.821

32

0.29

0.87

1.448

2.9

7.536

8.69

18.84

20.27

17.6715

40

0.452

1.36

2.26195

4.5239

9.0478

13.5717

22.6195

31.67

45.2389

50

0.707

2.12

3.53429

7.0686

14.1372

21.2058

35.3429

49.48

70.6858

65

1.195

3.58

5.97295

11.946

23.8918

35.8377

59.7295

83.62

119.459

80

1.810

5.43

9.04779

18.0956

36.1911

54.2867

90.4779

126.67

180.956

100

2.827

8.48

14.1372

28.274

56.5487

84.8230

141.372

197.92

282.743

125

4.417

13.25

22.08925

44.1775

88.3575

132.535

220.8925

309.25

441.7875

150

6.362

19.09

31.8086

63.617

127.235

190.852

318.086

445.32

636.173

200

11.310

33.93

56.5487

113.097

226.195

339.292

565.487

791.7

1130.973

250

17.671

53.01

88.3573

176.715

353.429

530.144

883.573

1236.97

1767.146

300

25.447

76.34

127.2345

254.469

508.938

763.407

1272.345

1781.29

2544.690

350

34.636

103.91

173.1803

346.361

692.721

1039.082

1731.803

2424.52

3463.606

400

45.239

135.72

226.1947

452.389

904.779

1357.168

2261.947

3166.76

4523.893

450

57.256

171.78

286.2776

572.555

1145.111

1717.666

2862.776

4007.885

5725.553

500

70.686

212.06

353.4292

706.858

1413.717

2120.575

3534.292

4948.02

7068.584

600

100.79

305.37

508.9380

1017.876

2035.752

3053.628

5089.380

7125.3

10178.76

700

138.54

415.62

692.7212

1385.442

2770.885

4156.327

6927.212

9697.8

13854.42

800

180.96

542.88

904.7787

1809.557

3619.115

5428.672

9047.787

12667.2

18095.57

900

229.02

687.06

1145.111

2290.221

4580.442

6870.663

11451.11

16031.4

22902.21

1000

282.74

848.22

1413.717

2827.433

5654.867

8482.300

14137.17

19791.8

28274.33

1200

407.15

1221.5

2053.752

4071.504

8143.008

12214.51

20357.52

28500.5

40715.04

1400

554.18

1662.5

2770.885

5541.769

11083.54

16625.31

27708.85

38792.4

55417.69

1600

723.82

2171.5

3619.115

7238.230

14476.46

21714.69

36191.15

50667.6

72382.30

1800

916.09

2748.3

4580.442

9169.884

18321.77

27482.65

45804.42

64126.2

91608.84

2000

1131.0

3392.9

5654.867

11309.73

22619.47

33929.20

56548.67

79168.1

113097.3

Note: V=1m/s~V=7m/s in the table are recommended flow meters for measuring flow rate/velocity, and the measurement accuracy is optimal within this recommended flow rate/velocity range.

图片关键词

图片关键词

图片关键词

FLDC电磁流量计企业资质

企业资质跳转

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!