VIP member
Fisher MR105 pressure reducing gas-liquid regulator
Fisher MR105 pressure reducing gas-liquid regulator
Product details
Product details introduction
Fisher MR105 pressure reducing gas-liquid regulator
The Fisher MR105 direct acting pressure regulator is a high flow multi-purpose regulator designed to provide fast and economical pressure control for various applications, suitable for different fluid media such as liquids, air, and gases. The Fisher MR105 valve is an ideal choice for applications where response speed is crucial, and where minimum pressure drop or impurities in the process fluid are a concern. Typical applications include lubricating oil, cooling water, and pump bypass regulators
characteristic
Steel and stainless steel structures comply with API 614 requirements
Adopting a structure that meets the requirements of NACE MR0175-2003 and NACE MR0103, it can be used for acidic gases
P 1= P2, Used for high-voltage actuators
Drain Valve
Pressure loaded actuator
Relief valve (only for high-pressure actuators)
Travel Indicator
specifications
Pressure collection method: external pressure collection
Temperature applicable range
Nitrile rubber (NBR):- 20 to 180 ° F/-29 to 82 ° C
Fluororubber (FKM): 20 to 250 ° F/-7 to 121 ° C;
Limited to 200 ° F/93 ° C in hot water
Ethylene propylene rubber (EPDM):- 20 to 225 ° F/-29 to 107 ° C
Valve body size
NPS 1 / 2 / 3 / 4 |DN25/DN50/DN80/DN100
End Connection
NPT/CL125FF/CL150RF/CL250RF/CL300RF/CL600R /PN16/25/40
Maximum inlet pressure: 400PSIG/27.6bar | or valve body rated pressure value, whichever is lower
Maximum outlet pressure: 400PSIG/27.6bar | or valve body rated pressure value, whichever is lower
Spring range
5 to 300 PSIG/0.4 to 20.7 bar

The Fisher MR105 direct acting pressure regulator is a high flow multi-purpose regulator designed to provide fast and economical pressure control for various applications, suitable for different fluid media such as liquids, air, and gases. The Fisher MR105 valve is an ideal choice for applications where response speed is crucial, and where minimum pressure drop or impurities in the process fluid are a concern. Typical applications include lubricating oil, cooling water, and pump bypass regulators
characteristic
Steel and stainless steel structures comply with API 614 requirements
Adopting a structure that meets the requirements of NACE MR0175-2003 and NACE MR0103, it can be used for acidic gases
P 1= P2, Used for high-voltage actuators
Drain Valve
Pressure loaded actuator
Relief valve (only for high-pressure actuators)
Travel Indicator
specifications
Pressure collection method: external pressure collection
Temperature applicable range
Nitrile rubber (NBR):- 20 to 180 ° F/-29 to 82 ° C
Fluororubber (FKM): 20 to 250 ° F/-7 to 121 ° C;
Limited to 200 ° F/93 ° C in hot water
Ethylene propylene rubber (EPDM):- 20 to 225 ° F/-29 to 107 ° C
Valve body size
NPS 1 / 2 / 3 / 4 |DN25/DN50/DN80/DN100
End Connection
NPT/CL125FF/CL150RF/CL250RF/CL300RF/CL600R /PN16/25/40
Maximum inlet pressure: 400PSIG/27.6bar | or valve body rated pressure value, whichever is lower
Maximum outlet pressure: 400PSIG/27.6bar | or valve body rated pressure value, whichever is lower
Spring range
5 to 300 PSIG/0.4 to 20.7 bar