brand | NGP/High Quality Technology | Origin category | domestic |
---|
Fixed online silane detector
Technical parameters:
Gas detection: Silane gas
Detection range:0~1PPM、10PPM、20PPM、100PPMThe measurement range is customized according to the usage environment or user needs
divide distinguish Rate:0.01ppm(0~100 ppm)
Detection principle: electrochemical method
Detection methods: fixed, online detection, diffusion measurement, pump suction measurement optional
Installation methods: wall mounted, pipe mounted, and flow-through options are available
Accuracy: ±3%FS
Display mode: LCD display (optional)
Response time:≤30second
Recovery time:≤60second
Explosion proof mark:ExiaⅡCT6 Ga
AApplicable to0 District1District2 District, containingIIA~IICClass,T1~T6Explosive gas mixture sites;
BThe product has passed the inspection of the National Explosion proof Electrical Product Quality Inspection Center and obtained the Explosion proof Certificate of Conformity;
Explosion proof connection thread:3/4'NPT
Analog signal output: three wire system4~20mALinear output
Digital signal output: bus systemRS485Digital signal output, in conjunction withRS232The adapter card can store data on the computer
Maximum transmission distance:1100Rice(Rvv0.75Square millimeter shielded cable),Can support wireless transmission without wiring
Working temperature:-20℃~+50℃
Relative humidity:10%~95%RH(Non condensing)
working pressure:≤200Kpa
Power supply:24VDC±12VDC
Maximum power consumption:2.5W
External dimensions:230X160X90
weight Quantity: Approximately1.5Kg
Fixed online silane detectorWidely used in industries such as petroleum, chemical, environmental protection, metallurgy, refining, gas transmission and distribution, pharmaceuticals, etc.