Fixed static grounding alarm
Fixed static grounding alarm
Product details

Fixed static grounding alarm

The BJQ-2 fixed electrostatic grounding alarm adopts high-quality chips and micro electronic circuits to continuously detect the resistance values of the connected equipment circuit and the grounding terminal circuit. Through the effective connection of the top, grounding clamp body, grounding clamp cable, grounding cable, and grounding pile, the connected equipment is equipotential with the ground, and static electricity is introduced into the ground to ensure that the resistance of the equipment's electrostatic grounding circuit meets national safety standards.

1. Scope of use:

Various mobile storage tanks such as cars and tank trucks; Gas stations and oil depots; Paint factories, pharmaceutical factories, alcohol factories, and chemical factories; And other places that require electrostatic grounding.

2. Working principle

2.1 Paint breaking principle:The broken paint needle on the head of the electrostatic clamp uses a lever composed of a strong spring and the clamp body to create a strong pressure, thereby breaking down barriers such as paint and rust.

2.2 Conductivity principle:The effective connection between the wire and the grounding post is achieved through a broken paint needle and an electrostatic clamp, which forms an equipotential between the object that needs to eliminate static electricity and the ground, and guides static electricity into the ground.

3. Performance characteristics

3.1 Explosion proof level:

Exia II CT4The anti-static and alarm performance is stable and reliable.

3.2 24-hour automatic duty, ultra-low power design. 3.3 Rapid response capability, able to respond to alarms within 1-2 seconds.

3.4 The interior of the alarm body is sealed with epoxy resin adhesive, suitable for various working environments; Safe and easy to use. Ultra low power consumption design.

4. Installation

The BJQ-2 fixed lithium battery electrostatic grounding alarm can be installed on walls or dedicated columns. During installation, the holes on the alarm can be fixed with expansion screws.

5. Use

During the installation process of the alarm, the alarm should be tested using the following methods:

[Fixed] Remove any wire from the grounding pile, the alarm will sound, and then connect the wire back to the grounding pile to stop the alarm sound.

If the test results do not match the above, the various parts of the alarm should be checked for any problems. The inspection method can be found in the installation precautions.

Attention: Failure to remove the static clamp for a long time may cause damage to the alarm!

If the alarm sound is low, it indicates that the battery is dead and the motherboard needs to be replaced.

The broken paint needle on the electrostatic clamp may become contaminated with oil or insulating substances during operation, which may cause the alarm to not sound. Please clean it regularly. Ensure good contact


(Product Introduction Diagram)
(Product Applicable Scenarios)