brand | ZKP/Zhongkepu |
---|
Principle of formaldehyde analyzer for liquefied gas:Liquefied gas analysis includes component analysis of liquefied gas and analysis of dimethyl ether, methanol, and formaldehyde in liquefied gas, excluding alkynes. It uses a gas chromatograph with a thermal conductivity detector to separate each component in the sample using a chromatographic column. The area normalization method or calibration area normalization method is used, and the percentage content of each component is measured by external standards.
GC-2020 typeFormaldehyde analyzer for liquefied gasPerformance characteristics
1. Adopting320 x 240dot matrix5.7An inch large screen LCD Chinese display, real-time display of various temperatures and operating conditions, clear and intuitive content, truly realizing human-machine dialogue;
2Power on self-test, wide range self diagnostic function, can accurately determine the fault location and alarm;
3Six independent temperature controls (vaporization chamber and capillary vaporization chamber can be independently controlled), Five level program heating function;
4Overtemperature Protection function: If any circuit exceeds the set temperature, the instrument will automatically power off and sound an alarm;
5The vertical heating device of * makes sample vaporization more reliable, reduces the heat radiation generated in the vaporization chamber to the minimum, and ensures minimal temperature deviation inside the column box;
6Intelligent fuzzy control rear door opening system, automatically tracks temperature and dynamically adjusts The angle of the air door can achieve precise temperature control even near room temperature;
7Configure filling column head injection, glass lining injection, with diaphragm cleaning Functional capillary diversion/Non split injection device and capable of installing gas injectors;
8High precision dual stable gas path, capable of installing four types of detectors simultaneously;
9Optional electronic flow pressure display system with built-in workstation device.
Temperature control indicators
1.Temperature control range: room temperature 5℃~400℃ increment0.1℃
2.Temperature control accuracy: superior to±0.01℃
Program heating: Five step interval constant temperature time0~999minincrement0.1minTemperature increment0.1℃
Heating rate:200℃The biggest one below40℃/min200℃Up to the biggest20℃/min
Main technical specifications of the detector
Hydrogen flame ionization detector(FID)
(1)Cylindrical collection electrode structure design, quartz nozzle, responsive*
(2)Detection limit:≤8×10g/s(HEXADECANE/isooctane)
(3)Baseline noise:≤2×10A
(4)Baseline drift:≤2×10A/30min
(5)Linear:≥10
Thermal conductivity detector(TCD)
(1)Adopting a semi diffusive structure
(2)The power supply adopts constant current control mode
(3)Sensitivity:≥2500mV·ml/mg(HEXADECANE/isooctane).
(4)Baseline noise:≤20μV.
(5)Baseline drift:≤100μV/30min.