Product Overview:
In the circulating water supply system, the treatment of circulating water quality should be considered based on the water quality used, and adding water treatment agents is one of the important measures for water quality treatment in the circulating water supply system. The series of dosing equipment produced by our company includes various performance water treatment agents such as water stabilizers, coagulants, disinfectants, etc. This device has the characteristics of compact structure, easy installation and operation, stable performance, low energy consumption, corrosion resistance, and low noise.
Operating instructions
1. When the dosing equipment must be used continuously, at least two sets of devices are required, one for operation. A set of formulated medication.
2. When adding chemicals, it is necessary to clean the circulating cooling water system with water or chemical cleaning. Activate the packing of the cooling tower and the metal surface of the heat exchanger pipeline, and then perform pre film treatment. The dosage of pre film agent is 200-300ppm. The pre film time is 24-48 hours.
3. According to the required concentration of the medicine solution, measure the amount of medicine and water based on the volume and purity of the medicine tank, add the medicine to eight medicine tanks, and then add the required amount of water.
4. Start the mixer. Dissolve the added medication completely and stir evenly. Before dosing, open the angle valve to fill the solution tank, adjust the measuring device to the required dosing amount, and then open the angle valve at the bottom of the solution tank to start dosing.
5. To prevent an increase in the concentration of circulating cooling water, pipeline filters and bypass filters need to be installed.
6. The residual substances in the solution tank and chemical tank can be discharged through the sewage pipe.
scope of application
1. The dissolution, mixing, and addition of coagulants, coagulants, and disinfectants in water supply engineering.
2. Preparation and addition of various acid-base solutions.
3. Preparation and addition of regeneration solution in softening and desalinated water treatment.
4. Preparation and addition of water quality stabilizers for circulating cooling water.
Ordering precautions
1. To meet the different needs of users, the dosing methods of JD series and JY series dosing equipment are divided into three forms: metering pump, gravity type, and water jet. The liquid metering methods are divided into metering pump and flow meter. JY type no solution tank.
2. If the user has special needs, our company can provide combined dosing equipment, which is composed of two sets of dosing equipment. Please specify when ordering.
3. Our company adheres to the principle of quality first, customer first, and reputation first. We sincerely serve our customers and can provide various equipment for water treatment.
In the circulating water supply system, the treatment of circulating water quality should be considered based on the water quality used, and adding water treatment agents is one of the important measures for water quality treatment in the circulating water supply system. The series of dosing equipment produced by our company includes various performance water treatment agents such as water stabilizers, coagulants, disinfectants, etc. This device has the characteristics of compact structure, easy installation and operation, stable performance, low energy consumption, corrosion resistance, and low noise.
Operating instructions
1. When the dosing equipment must be used continuously, at least two sets of devices are required, one for operation. A set of formulated medication.
2. When adding chemicals, it is necessary to clean the circulating cooling water system with water or chemical cleaning. Activate the packing of the cooling tower and the metal surface of the heat exchanger pipeline, and then perform pre film treatment. The dosage of pre film agent is 200-300ppm. The pre film time is 24-48 hours.
3. According to the required concentration of the medicine solution, measure the amount of medicine and water based on the volume and purity of the medicine tank, add the medicine to eight medicine tanks, and then add the required amount of water.
4. Start the mixer. Dissolve the added medication completely and stir evenly. Before dosing, open the angle valve to fill the solution tank, adjust the measuring device to the required dosing amount, and then open the angle valve at the bottom of the solution tank to start dosing.
5. To prevent an increase in the concentration of circulating cooling water, pipeline filters and bypass filters need to be installed.
6. The residual substances in the solution tank and chemical tank can be discharged through the sewage pipe.
scope of application
1. The dissolution, mixing, and addition of coagulants, coagulants, and disinfectants in water supply engineering.
2. Preparation and addition of various acid-base solutions.
3. Preparation and addition of regeneration solution in softening and desalinated water treatment.
4. Preparation and addition of water quality stabilizers for circulating cooling water.
Ordering precautions
1. To meet the different needs of users, the dosing methods of JD series and JY series dosing equipment are divided into three forms: metering pump, gravity type, and water jet. The liquid metering methods are divided into metering pump and flow meter. JY type no solution tank.
2. If the user has special needs, our company can provide combined dosing equipment, which is composed of two sets of dosing equipment. Please specify when ordering.
3. Our company adheres to the principle of quality first, customer first, and reputation first. We sincerely serve our customers and can provide various equipment for water treatment.
Online inquiry