Dachang Yanghang (Shanghai) Co., Ltd
Home>Products>Fully automatic six station dynamic method rapid surface area tester
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Unit 605-607, Building 2, Xinglian Research Building, No. 1535 Hongmei Road, Shanghai [2023]
Contact Now
Fully automatic six station dynamic method rapid surface area tester
Fully automatic six station dynamic method rapid surface area tester
Product details
product details

MicrotracBEL Corp. (Japan)- Expert in surface adsorption technology

MicrotracBEL Corp. (Japan)We are a professional manufacturer specializing in the research and production of volumetric/gravimetric gas adsorption analyzers. Adhering to the concept of "Business for Enjoying Life", we draw on the strengths of various companies to manufacture high-quality instruments. Career makes life more enjoyable "originates from the drive of originality and continuous innovation. The multifunctional catalyst characterization system, pioneering fully automatic steam adsorption system, solid electrolyte membrane moisture adsorption and proton conductivity analyzer, fuel cell comprehensive evaluation device, etc. have greatly enriched the surface adsorption characterization methods and also won a good reputation for Bayer's high-quality products and services.


characteristic:

Test the single point BET specific surface area of a sample in 10 minutes

High sensitivity TCD sensor, no need for pulse adsorption calibration

Single point/multi-point BET

Simultaneously measure 6 samples

Support the requirements of 21 CFR Part 11 by the US FDA


Test principle: Dynamic gas flow method Flow gas adsorption method

Test mode: Single point/multi-point BET

Multiple BET relative pressure points can be freely selected (optional)

Number of test samples: Simultaneously measure 6 samples

Adsorbed gas type: nitrogen N2 or krypton Kr

Pre treatment temperature: 35-400 ℃

Measuring relative pressure range: 0.30, 0.02-0.9 (upgraded)

Surface area testing range:> 0.01m2/g

Repeatability: ± 1%

Testing time: Approximately 10 minutes per sample

Support the requirements of 21 CFR Part 11 by the US FDA (the pharmaceutical industry needs to comply with this requirement)

Size: W394 × D460 × H635 (mm)


*Using highly sensitive TCD sensors without the need for pulse adsorption calibration


Optional accessories:

Option 1: Mixing unit, used for convenient testing of multi-point BET without the need for gas cylinder mixing.

Option 2: Automatic liquid nitrogen addition system for continuous testing of more samples.

Product parameters