G2204 gas concentration analyzer
G2204 gas concentration analyzer
Product details

Product Overview

The Picarro G2204 gas concentration analyzer can accurately measure methane (CH4) and hydrogen sulfide (H2S) simultaneously, with a sensitivity of parts per billion (ppb). The drift generated by emission measurements for landfills, refineries, paper mills, or industrial plants can be ignored. This analyzer can be installed in just a few minutes for static monitoring applications, as well as for remote quantitative emission applications that exceed the warning line. It is coupled using the US Environmental Protection Agency's Geospatial Method (EPA's other testing method OTM 33).

Product Features

Simultaneous and continuous measurement of CH4 and H2S concentrations

Billion parts per billion (ppb) sensitivity, accuracy, and precision, with extremely low drift

Application for static monitoring or remote quantification of emissions beyond warning lines

Durable and sturdy structure, insensitive to environmental temperature changes

Main technical parameters

Picarro G2204methane(CH4)

parameter

Specification (requires air like substrate)

notes

Accuracy(5.0 Seconds)

2 ppb

1-σ

Maximum drift (exceeding) 8 Hour)

< 4 ppb

50 The difference between the maximum values of the minute averages

measuring range

The accuracy at high concentrations is approximately the same as the reading1%)

Ensure that the specification range is0 - 3 ppmThe scope of work is0 - 20 ppm

Measurement interval

about 5 second

rise time/Descent time

< 5.0second

10 - 90% / 90 - 10%

Picarro G2204hydrogen sulfide(H2S)

parameter

Specification (requires air like substrate)

notes

Minimum detection limit(5 Minutes)

3 ppb

3-σ

Zero drift(8 Within hours)

< 3 ppb

50 Peak of minute mean-peak value

Measurement range(5 The accuracy of the minute average is1 ppb

+ 0.4%

The scope of work is0 - 300 ppm

Ensure that the specifications are0 - 20 ppm

Measurement interval

about 5 second

rise time/Descent time

< 5second

10 - 90% / 90 - 10%

Picarro G2204Instrument specifications

measuring technique

Cavity oscillation spectroscopy(CRDS)technology

Measurement pool temperature control

± 0.005 ℃

Measurement pool pressure control

± 0.0002Atmospheric pressure

Sample temperature

-10 to45 ℃

Sample flow rate

stay760 Underneath less than 0.4 Standard liters per minute(slm)No need for filtering

Sample pressure

300 to 1000 Tuo(40 to 133 Kilopascals)

Maximum rate of change in ambient temperature

Every hour5 ℃

Sample humidity

relative humidity(RH)less than99%(In)40 ℃Under non condensing conditions, there is no need for drying

ambient temperature

10 to35 ℃(Running), -10 to50 ℃(Storage)

ambient humidity

relative humidity(RH)less than99%Under non condensing conditions

Other gases measured

H2O

enclosure

Pump (external, included), keyboard (included), mouse (included)LCDMonitor (optional)

data output

RS-232EthernetUSBSimulation (optional)0 - 10Fu

Air inlet connector

¼inchSwagelok ®Connector

External dimensions

Including the legs, it is 17 Inches widex 7Inch heightx 17.5Inch length(43.2 x 17.9 x 44.5centimeter)When excluding small external pump modules, it is 7.5 Inches widex 4Inch heightx 11Inch length(19 x 10.2 x 28centimeter)

Installation form

Workbench or 19 Inch rack mounted chassis

weight

60.4 pound(27.4Kilogram), including pumps

Power requirements

100 - 240Alternating current,47 - 63 Hz(Automatic detection), when started (total) less than 260 Tile;

110 Watt (analyzer), steady state is 80 Watt (pump)

Application precautions

We need an air like substrate. WhenH2OCO2 andCH4 Concentrations far above normal environmental levels, as well as the presence of compounds including but not limited to ethane, acetylene, and other nitrogen-containing and sulfur-containing substances, may interfere with measurements. For more details about the experimental conditions, please contact us.