Jiangsu Guochuang Analytical Instrument Co., Ltd
Home>Products>GCTNS-9000 Fully Automatic Sulfur and Nitrogen Analyzer
GCTNS-9000 Fully Automatic Sulfur and Nitrogen Analyzer
Brief description: The GCTNS-9000 fully automatic sulfur and nitrogen analyzer uses UV fluorescence method to determine total sulfur content and chemi
Product details
brand Self operated brand Price range discuss personally
Origin category domestic application area Environmental protection, chemical industry, biotechnology, petroleum, energy

Characteristics: High degree of automation

be based onWindowsChinese operation interface, direct human-machine dialogue. The collection, processing, storage, and printing of data are controlled by computers.The instrument automatically adjusts gas flow rate, samples, cleans, changes samples, generates standard curves, and goes into sleep mode after the analysis process is completed. It can also be set to wake up at regular intervals, fully realizing unmanned analysis.

Instrument execution standards

SH/T 0689-2000 Determination of Total Sulfur Content in Light Hydrocarbons, Engine Fuels, and Other Oil Products (Ultraviolet Fluorescence Method)

ASTM D 5453 -2006 Standard Test Method for Total Sulfur in Light Hydrocarbons, Spark Ignition Engine Fuels, Diesel Engine Oils, and Engine Oils by Ultraviolet Fluorescence Measurement

ASTM D6667-2014 Standard Test Method for Total Volatile Sulfur Content in Gaseous Hydrocarbons and Liquefied Petroleum Gas by Ultraviolet Fluorescence Method

ASTM D7183-2012 Standard Test Method for Total Sulfur Content in Aromatic Hydrocarbons and Related Compounds by Ultraviolet Fluorescence Method.EN ISO 20846: 2004 Standard Title Petroleum Products Determination of Sulfur Content in Motor Vehicle Fuel Ultraviolet Fluorescence Analysis Method

GB/T17930-2011 Automotive Gasoline

GB/T 19147-2009 Automotive Diesel Fuel

ISO 20846-2011 Petroleum products - Determination of sulfur content in automotive fuels

BS EN 15486-2007 Ethanol is a mixed component of petroleum Determination of sulfur content
SH/T 0657-1998 Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons (Oxidative Combustion and Chemiluminescence Method)
ASTM D4629-2010 Standard Test Method for Trace Organic Compound Nitrogen in Liquid Petroleum Hydrocarbons by Injection/Insertion Oxidized Fuel and Chemiluminescence Method

ASTM D5762-2010 Test Method for Nitrogen in Petroleum and Petroleum Products by Ship Inlet Chemiluminescence Method

ASTM D6069-2001- Standard Test Method for Trace Nitrogen in Aviation Hydrocarbons by Oxidative Combustion and Reduction Pressure Chemiluminescence Detection

system configuration

Standard configuration: Computer+GCTNS-9000 system+fully automaticinjector16 bit or 110 bit

GCTNS-9Type 000Fully automatic sulfur and nitrogen analyzerTechnical Parameter

Technical Parameter
Basic parameters: Sample type: Liquid
Measurement method: UV fluorescence method(S) Chemiluminescence method(N)
Sample injection volume: Liquid sample:2-25μL   
Measurement range:0.0510000mg/L (S) 0.0510000mg/L (N)

Measurement accuracy:

Concentration value(ppm)

Injection volume(μL)

RSD(%)

0.11.0

20

10

110

10

6

101

10

2

100

10

1

Detection limit:0.1ppm

Temperature control range: room temperature~1300℃

Temperature control accuracy:±1

Gas source requirement: high-purity argon gas: purity99.98%Above
High purity oxygen: purity99.98%Above

Power supply:AC220V±22V,50Hz±0.5Hz,1500 W

Dimensions: Host:505(W)×541(D)×960(H)mm
Weight: Host:40kg

GCTNS-9Type 000Fully automatic sulfur and nitrogen analyzeradvantage

  1. The instrument adoptsVertical injectionmode.

  2. Implement injection needleAutomatic cleaning and sample replacementThe program can be set according to requirements.

  3. select16positionthe aboveFully automatic sampler, accurate positioning, one-time setting, fully automatic detectionIt can automatically set the injection volume. Realize unmanned operation and automatic analysis.

  4. The gas flow rate is precisely controlled by a mass flow meterNo manual adjustment is required.

  5. The gas pressure and temperature are precisely controlled by response sensors.

  6. The computer controls the entire process of analysis, data processing, etc., and displays the working status of the entire process. The standard curve can be automatically completed.

  7. Using imported high-quality heating furnace wire,extendLong service life of cracking furnace. The data processing software has an over temperature protection and automatic cut-off function. When the temperature exceeds the set limitlimitThe instrument automatically cools down and enters a protective state.

  8. Fluorescence design *Sulfur reaction chamberIt has an automatic compensation function for ultraviolet light source intensity, high sensitivity, and low baseline noise.

  9. *The nitrogen reaction chamber enhances the reaction intensity between nitric oxide and ozone, as well as rapidly discharges exhaust gas and reduces tailing.

  10. The aromatic hydrocarbon barrier filtration system and detection system with selective permeable membrane are impossible to contaminate.

  11. Specially designed quartz cracking tube, no need to disassemble or replace, completely solves the problem of carbon deposition in combustion tubes.

  12. The instrument is equipped with a gas filtration and purification system.

  13. Abnormal gas flow rate and pressure, automatic cooling protection of the instrument.

  14. Gas pipelines are connected using spherical clamps for easy maintenance.

  15. The instrument can set the temperature and wake-up time of the cracking furnace during sleep. After the analysis of the sample is completed, the instrument automatically enters a sleep state, and when the set wake-up time is reached, the instrument automatically starts working without the need for operators to be present.

  16. The key components are imported componentsReduced instrument noise and improved detection sensitivity.



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!