Tag: High precision flux gate desktop 3D flux gate weak magnetic Gaussian meter residual magnetism measuring instrument shielding effect measuring instrument
Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G92 |
hall |
handheld |
1 |
1% |
10T |
10μT |
G93 |
hall |
handheld |
3 |
1%, 0.5% |
20T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G203 |
hall/reluctance |
Desktop computer |
3 |
0.2% |
10T |
10nT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
GSP301A |
hall |
Analog transmitter |
1 |
1%, 0.2% |
10T |
Output: ±3V |
GSP301D |
hall |
Digital transmitter |
1 |
1%, 0.2% |
10T |
1μT |
GSP303D |
hall |
Digital transmitter |
3 |
1%, 0.2% |
20T |
1μT |
GSP303D-S |
hall |
Digital transmitter |
3 |
0.5%, 0.1% |
3T |
1μT |
Magnetic field testing system | ||||||
GAS3000 |
Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location |
|||||
GMS980 |
High precision Gaussian meter calibration system (High precision Tesla meter calibration device) |
|||||
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
1mT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP703 |
fluxgate |
Smart Transmitters |
3 |
0.5% |
1mT |
0.1nT |
GFP703S |
fluxgate |
Spectrum analyzer |
3 |
0.5% |
1mT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
G1000 |
reluctance |
Smart Transmitters |
3 |
DC- 1% AC- 2% |
400μT/ Axis |
DC- 1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
GSP301HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
GSP303HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
F23 |
fluxgate |
split type|large range |
3 |
<> |
1500μT |
±10V,single-ended |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
Magnetic flux gate sensor data acquisition unit | ||||||
FDU301 |
Connectable1A three-axis flux gate sensor |
|||||
ASA1000 |
Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor |
|||||
AFS |
Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters |
|||||
GMR-16 |
Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor |
|||||
GR100 |
Digital three-axis flux gate gradiometer |
|||||
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
sketch:
The Gaussian meter GF633 is a desktop 3D flux gate Gaussian meter with ultra-high precision and resolution, used for detecting weak magnetic fields in scientific research, military industry, and other applications. The 9-inch color industrial touch screen provides rich display content and features real-time XYZ component values, vector values, D/I values, real-time spectrum analysis, and time-domain graphs of magnetic field strength.
The Gaussian meter GF633 can measure DC magnetic field in DC mode and true effective value AC magnetic field in AC mode: DC basic accuracy of 0.1%, range of ± 100 μ T, resolution of up to 0.01nT, frequency response range of DC-3kHz.
The Gauss meter GF633 adopts a 9-inch color industrial resistance touch screen with a built-in graphical interface operating system, which is easy to operate and users can use it without reading the manual; Adopting aviation aluminum alloy shell, small size, saving desktop space, low-power fanless design, green and environmentally friendly.
The Gaussian meter GF633 has passed CE certification and EMC (electromagnetic compatibility) testing.
characteristic | |
● Ergonomic design ● Graphical interface operating system ● 9-inch LCD touch screen ● Full 6-digit display ● Time domain graph display and D/I value display ● Display of XYZ component values and vector values ● Real time spectrum analysis function |
● Range: ± 100 μ T ● DC basic accuracy: 0.1% ● Resolution up to 0.01nT ● DC/AC measurement mode switching ● Orthogonal error:<> ● Frequency response range: DC- 3kHz ● Intelligent recording and viewing function |
![]() |
![]() |
![]() |
![]() |
![]() |
GF633 3D Flux GateGauss meter parameters:
model |
GF633 |
||
Measurement parameters | |||
Accuracy/Axis |
DC |
±0.1% Reading ± 0.1% FS |
|
AC |
±0.5% Reading ± 0.1% FS [fT≤ 100Hz] ±1% Reading ± 0.1% FS [100Hz <>T≤ 300Hz] ±2% Reading ± 0.1% FS [300Hz <>T≤ 1kHz] ±10% Reading ± 0.1% FS [1kHz < =''>T≤ 3kHz] |
||
maximum range |
X, Y,Z |
DC |
±100μT |
AC* |
±70μT |
||
Vector R |
DC |
173μT |
|
AC* |
121.2μT |
||
Highest resolution |
0.01nT |
||
Display digits |
6 people |
||
Frequency response range [f]T] |
DC - 3kHz |
||
Sensor three-axis orthogonality error |
0.05° |
||
Typical temperature coefficient |
±20ppm/℃ |
||
hysteresis |
±2nT (exposed to a magnetic field environment up to twice the range) |
||
zero error |
±5nT |
||
Host storage capacity |
>8000 pieces of data |
||
front panel | |||
display type |
9-inch color resistive touch screen, 800x600 pixels |
||
Display units |
Natsra (nT) |
||
Display update rate |
4 times per second |
||
display mode |
DC、AC、 Vector value, XYZ component value, D/I value, alarm, time-domain graph, real-time spectrum analysis |
||
probe | |||
Start time/preheating time |
150ms; 15min |
||
probe Type |
details“Probe specificationslist |
||
connector |
IP67 waterproof connector |
||
Probe handle and protective cover |
Non magnetic aviation aluminum alloy, resistant to a 10 meter drop |
||
Cable line |
Shielded twisted pair flexible cable, compliant with CAT5e standard |
||
Cable Length |
Standard 1.5 meters; Customizable up to 30 meters in length |
||
USBinterface | |||
function |
1. Communication: used to connect to computers, display measurement data, etc; 2. Power supply: used to connect a 5VDC charger or a portable power bank (power bank). |
||
Software/Drivers |
Upper computer software, no need to install other drivers |
||
Host specifications | |||
operation temperature |
+15 ℃ to+35 ℃ (rated accuracy) -10 ℃ to+60 ℃ (decreased accuracy) |
||
storage temperature |
-20 ℃ to+75 ℃ |
||
Environmental magnetic field |
<20g>20g> |
||
power supply |
5VDC, can be connected to a portable power bank for power supply |
||
power interface |
Type-C USB |
||
Size (excluding detachable base) |
281 mm W × 164 mm H × 26 mm D |
||
weight |
1.52kg |
||
material |
High strength aviation aluminum alloy |
||
authentication |
CE certification, EMC certification |
The AC range described here refers to the measurement range of the AC magnetic field after shielding the DC magnetic field. Therefore, if the AC measurement mode is used to measure the magnetic field in an unshielded DC magnetic field environment, the AC range is equal to 0.7 times the DC range minus the DC magnetic field strength in that environment. [SQRT(2)/2 ≈ 0.7]。
Probe specifications
![]() |
GF633Three dimensional flux gate Gaussian meter probe | |||||||
probe type |
range |
frequency response |
typical temperature coefficient |
midnighterror |
DCaccuracy (25℃) |
material |
|
(X, Y, Z axes) |
(Vector R) |
||||||
GF-Y01H |
±100μT |
173μT |
DC-3kHz |
±20ppm/℃ |
±5nT |
±0.1% Reading ± 0.1% FS |
POM |
Note: 1. 1G=100 μ T=100000NT;
2. The probe size is 200 x 30 x 30mm, and the working temperature range of the probe is -20 ℃ to+60 ℃;
3. The default protection level for the probe is IP66. If you need packaging with other protection levels, please contact Colin;
4. The highest protection level packaging of the probe can support long-term operation of the probe underwater for 50 meters.
Options
type |
describe |
GHOLD100 |
The three-dimensional mobile platform of the probe is made of non-magnetic materials. The user fixes the probe at the front end of the bracket and manually rotates the knob to make the probe move along X, Y. Move steadily in the Z-axis direction to a certain position and lock it in place. The stroke of each axis is 150mm, the positioning accuracy is 0.1mm, the center load is 10kg, and the self weight is 3.5kg |
PS-1W |
Mobile power bank, can be used as an external power source for GF633 Gauss meter, powered through USB interface. Capacity: 10000mAh; Output: 5V/2A |
SAMRT PC Software |
Computer software for Gauss meter (included with the instrument) |
Probe extension cable |
Up to 30 meters in length |
The most commonly used kit |
Kit Product Number GF63301: Gauss Meter Host GF633+Probe GF-Y01H |