Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G92 |
hall |
handheld |
1 |
1% |
10T |
10μT |
G93 |
hall |
handheld |
3 |
1%, 0.5% |
20T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G203 |
hall/reluctance |
Desktop computer |
3 |
0.2% |
10T |
10nT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
GSP301A |
hall |
Analog transmitter |
1 |
1%, 0.2% |
10T |
Output: ±3V |
GSP301D |
hall |
Digital transmitter |
1 |
1%, 0.2% |
10T |
1μT |
GSP303D |
hall |
Digital transmitter |
3 |
1%, 0.2% |
20T |
1μT |
GSP303D-S |
hall |
Digital transmitter |
3 |
0.5%, 0.1% |
3T |
1μT |
Magnetic field testing system | ||||||
GAS3000 |
Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location |
|||||
GMS980 |
High precision Gaussian meter calibration system (High precision Tesla meter calibration device) |
|||||
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
1mT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP703 |
fluxgate |
Smart Transmitters |
3 |
0.5% |
1mT |
0.1nT |
GFP703S |
fluxgate |
Spectrum analyzer |
3 |
0.5% |
1mT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
G1000 |
reluctance |
Smart Transmitters |
3 |
DC- 1% AC- 2% |
400μT/ Axis |
DC- 1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
GSP301HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
GSP303HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
F23 |
fluxgate |
split type|large range |
3 |
<> |
1500μT |
±10V,single-ended |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
Magnetic flux gate sensor data acquisition unit | ||||||
FDU301 |
Connectable1A three-axis flux gate sensor |
|||||
ASA1000 |
Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor |
|||||
AFS |
Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters |
|||||
GMR-16 |
Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor |
|||||
GR100 |
Digital three-axis flux gate gradiometer |
|||||
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
GMR64 single axis micro probe weak magnetic field Gaussian meter
sketch:
Kore Technology GmbH in Germany has rich experience in magnetic field testing and has launched the GMR64 single axis micro probe weak magnetic field Gaussian meter. Its probe is compact and powerful, with a measurement resolution of up to 1nT and excellent zero temperature coefficient (1nT/℃). It displays<± 10nt at absolute zero magnetic field, with a display update rate of 1 time>± 10nt and a display update rate of 1 time>
The GMR64 single dimensional weak magnetic field Gaussian meter uses a miniature magnetic field sensor from COLIY company. The probe size is much smaller than that of a flux gate probe with the same performance: the probe thickness is only 2mm and the width is only 5mm, which is very convenient for measuring weak magnetic fields with narrow gaps and can be easily inserted into small holes.
The GMR64 single dimensional weak magnetic field Gaussian meter has a maximum range of 400 μ T, a DC accuracy of 0.5%, and a measurement resolution of up to 1nT, which can accurately measure weak magnetic fields; Display at absolute zero magnetic field<>
The GMR64 single dimensional weak magnetic field Gaussian meter has passed CE certification and EMC (electromagnetic compatibility) testing.
characteristic | |
● Shielding of cavity magnetic fieldEffect detection ●Ergonomic design ●Graphical interface operating system ●3.2-inch LCD color touch screen ●Maximum/minimum/hold function ●Intelligent recording and viewing ●DC/AC measurement mode switching |
●The probe thickness is only 2mm ●The probe width is only 5mm ●Measurement range 400 μ T ● MeasurementResolution of 1nT ●DC accuracy: 0.5% ● Zero temperature coefficient1nT/℃ ●Display at absolute zero magnetic field<> |
|
![]() |
GMR64 single dimensional weak magnetic field Gaussian meterparameter:
model |
GMR64 |
Measurement parameters | |
accuracy(DC) |
±0.5% |
range |
400μT (4G) |
resolution |
1nT (10μG) |
Display digits |
5position |
Frequency response range[fT] |
DC - 80Hz |
Absolute zero point |
< =''> |
zero temperature |
±1nT/℃ |
hysteresis |
<5nt>5nt>Exposed to magnetic fields up to twice the range) |
front panel | |
display type |
3.2Inch color resistive touch screen,320x240pixel |
Display units |
Gaussian(G)Tesla(T) |
Display update rate |
1order/second |
display mode |
DC、ACMaximum value, minimum value, alarm, etc |
probe | |
Compatible probes |
details“Probe specifications”list |
Probe cable length |
standard1.5Rice; |
USBinterface | |
function |
1Communication interface: used for connectingPCMonitor and measure with Gaussian meter host; 2Charging interface: used for connectingPCOr a portable power bank(power bank)Charge the Gaussian meter host. |
software/drive |
Upper computer software, no need to install other drivers |
Host specifications | |
operation temperature |
-10℃to +50℃ |
storage temperature |
- 20℃to +60℃ |
Environmental magnetic field |
<> |
battery |
rechargeable4400mAHLithium Ion Battery |
Battery operating time |
>20Hour (standard test environment) |
size |
238 mmW× 95 mmH× 42 mmD |
weight |
350g |
qualification |
CECertificationEMCauthentication |
Probe specifications
![]() |
GMR64Single dimensional weak magnetic field Gaussian meter probe | |||||||
probe Type |
maximum range |
resolution |
Frequency response range |
Probe rod size (mm) |
operation temperature |
DCaccuracy (25℃) |
Probe rod material |
Weak magnetic field probe T06L150GMR64 |
4G (400μT) |
0.01mG (1nT) |
DC -80Hz |
60*5*2 |
-20℃- +60℃ |
±0.5% |
plastics |