GXF and SJG series pipeline diagonal flow fans
The GXF and SJG series pipeline diagonal flow fans adopt drum shaped (SJG) or straight shaped (GXF) air ducts, with a conical impeller hub and a relat
Product details

GXF and SJG series pipeline diagonal flow fans

product overview

The GXF and SJG series pipeline diagonal flow fans adopt drum shaped (SJG) or straight shaped (GXF) air ducts, with a conical impeller hub and a relatively small inlet diameter of the hub, which accelerates the airflow on the meridian plane and avoids the separation of airflow caused by the impeller and the rear guide foot large protrusion, thus enabling the fan to achieve high efficiency and low noise. Due to the increase in axial velocity of the airflow in the fan channel, the static pressure gradient decreases, avoiding airflow detachment and achieving a higher pressure coefficient.

Model Description

give an example: GXF-BX1-9A/9S

GXF

Unit type: SDF series pipeline pressurized axial flow fan

BX1

Silencing type: The shell body does not come with a silencer, while the air inlet and outlet are equipped with silencers.

9

Fan number: 9 # (impeller diameter=9 * 100mm)

A/S

Motor type: Dual speed

All departments: A(S): Dual speed B: Single speed

give an example: (F)SJG-BX2-8.0E

(F)

fiberglass

SJG

Unit type: SJG series pipeline pressurized axial flow fan

BX2

Silencing type: The exterior and inlet/outlet are equipped with mufflers.

8.0

Fan number: 8.0 (impeller diameter=8 * 100mm)

E

Motor speed: 720rpm

All departments: D:2900rpm; F:1450rpm; S:960rpm; E:720rpm

CLASSIFICATION

SJG drum fans are divided into 4 types of speeds according to their machine numbers: 2 # to 8 #, 2900rpm (D), 1450rpm (F), 960rpm (S), and 720rpm (E), with a total of 20 types. The air volume range is from 200 to 25000m3/h. The full pressure range is from 50 to 1200Pa.

GXF straight fans are divided into two types according to their machine numbers: 4A/14B to 14A/14B, Type A (dual speed, some design drawings may also use "S" to indicate dual speed) and Type B (single speed), with a total of 28 types. The air volume range is from 2470 to 114900m3/h, and the total pressure range is from 130 to 1320Pa.

Fans can be customized with wind caps according to the needs of the location, and the identification method is to add the letter "W" after the machine number.

BX silencing fans are divided into: BX1、BX2。

The BX1 fan casing does not come with a muffler, but the inlet and outlet are equipped with mufflers; The BX2 type fan is equipped with mufflers on the exterior and inlet/outlet ports. The length of the muffler is 500mm, 750mm, 1000mm, and 2000mm; Users can customize the length according to their needs.

Silencer position

Fan casing

Inlet and outlet

Inlet and outlet

Inlet and outlet

Inlet and outlet

Silencer size

Wind tube size

Entering: 500mm

Out: 500mm

Entering: 750mm

Out: 750mm

Entering: 1000mm

Out: 1000mm

Entering: 2000mm

Output: 2000mm

Silencing volume dB (A)

3-5

3-8

5-11

8-14

11-17

Fans can be customized into fiberglass anti-corrosion (F) and explosion-proof types according to environmental requirements.

working conditions

operation temperature

humidity

Medium conditions

Working power supply

﹣20~+45℃

(Can operate continuously)

<90%

air

(Dust content not exceeding 100mg/m ³)

Three phase 380V/50Hz

Product Application

Fans can be widely used in ventilation and air exchange places such as high-rise buildings, industrial and mining enterprises, hotels, restaurants, museums, sports halls, underground garages, etc., to meet the requirements of pipeline pressurization, air supply and exhaust, and ventilation and air exchange in high-rise or general buildings.

Fan configuration

Standard configuration:

Impeller, casing (air duct, guide vanes, inner cylinder, motor bracket), motor, feet, etc.

Optional parts and accessories (indicate whether purchased when ordering):

Muffler, vibration reduction equipment, dedicated electrical control box, mesh cover, docking flange.

Processing technology

The fan impeller is made of steel, the hub is hydraulically stretched and formed, the blades are hydraulically formed after stamping, and the blades are welded and assembled with the hub. The impeller has undergone static and dynamic balance correction, and the balance accuracy is not greater than G5.6 level.

The outer cylinder flange is made by integral flanging and spinning. In order to maintain consistency with the installation size of the user, the company's products will not drill holes on the flange unless otherwise specified by the user.

Wind vent muffler (optional) mold hydraulic/flanging and spinning forming. The inner layer is made of galvanized sound-absorbing microporous plate, and the interlayer is made of high-temperature resistant sound-absorbing cotton.

Our company has been committed to improving and optimizing our products. Product specifications and parameter dimensions are subject to change without prior notice.

No corresponding parameter group found, please add it in the backend property template
Not yet implemented, please stay tuned
Not yet implemented, please stay tuned
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!