Gas chromatograph rental
Gas chromatograph rental: Universal gas chromatograph/FID detector gas chromatograph/hydrogen flame ionization gas chromatograph GC-9800 gas chromatog
Product details

Gas chromatograph rental

Gas chromatograph rentalUniversal gas chromatograph/FID detector gas chromatograph/hydrogen flame ionization gas chromatograph
GC-9800 gas chromatograph - universal type generally refers to a gas chromatograph equipped with one or two of the universal detectors (FID, TCD detector, i.e. hydrogen flame ionization detector, thermal conductivity cell detector) (each instrument can be configured with up to three detectors (commonly used detectors are shown in Appendix 1 of this article). Please select different detectors according to your testing requirements. The selection principles of detectors are as follows: gas chromatograph - various detectors

Product project

Specification Description

quantity

Company

GC-9800

Gas chromatograph

Chromatograph host+gas path control system+dual six way valve injection system+amplification circuit control+dual CPU control system+host fault diagnosis sound and light Chinese display+output system

1

set

Detector 1

FID

1

only

Detector 2

TCD (optional)

1

only

chromatographic column

Analysis specific column;

Each 1

only

Control computer+printer

Adapt to the host

1

set

workstation

SP-2000 Dual Channel Multifunctional Workstation+Random Accessories

1

set

Gas source

Air generator, hydrogen generator, (nitrogen self equipped)

1 set

Starter Kits

Random giveaways (over 30 types)

1

set

Main performance characteristics:&, amp;, amp;, amp;, lt;, BR>1、 The instrument adopts a fully microcomputer automatic control system, an adjustable LCD display screen, and rich and intuitive display content; Chinese keyboard style operation, setting parameters and operation are very convenient.
2. Adopting a brand new dual CPU design and original Japanese high integration electronic circuit technology, it has excellent reliability and anti-interference ability. The temperature control accuracy reaches 0.1 ℃, and the display accuracy is as high as 0.01 ℃. It can also display the power consumption percentage of each heating part at the same time.
3. The design of a three gas path and a large volume column chamber allows for the simultaneous installation of three chromatography columns, FID and TCD detectors, and facilitates the expansion of ECD, FPD, and NPD detectors, as well as the installation of external control equipment such as gas injectors and converters.
4. This machine can be easily expanded from a single FID amplifier to a dual FID amplifier, truly achieving multi-purpose use of one machine.
5. Equipped with two packed column vaporization chambers and an independent capillary dedicated system, the design of the vaporization chamber draws on the miniaturization design of similar foreign products, with fast heating speed, no injection dead corners, excellent capillary diversion/non diversion injector and tail blowing system, making it easy to install small-diameter capillary columns, large-diameter capillary columns, and various packed columns.
6. It has a five order linear program heating function, which is suitable for multi-component sample analysis.
7. The column chamber is equipped with a frequency conversion intelligent rear door automatic cooling system, which has a very fast cooling speed (from 280 ℃ to 50 ℃ in just 5 minutes), achieving true near room temperature operation.
8. Equipped with six independent temperature control systems Suitable for the installation of multiple temperature control requirements such as conversion furnaces; The column chamber, gasification chamber, hydrogen flame detection chamber, thermal conductivity detection chamber, auxiliary 1, and auxiliary 2 all adopt modular design, making installation and replacement more convenient.
9. It has power failure protection function and can automatically memorize set parameters. It has anti power mutation interference function and stopwatch timing function.
10. Equipped with over temperature protection function, the power automatically shuts off and an alarm is triggered when the temperature exceeds the set upper limit. If the temperature of any circuit exceeds the set temperature, heating will automatically stop; And there are prompts for the cause of the malfunction and alarm prompts.

11. It has a "0 ℃" protection function. When the temperature display of any channel is always "0 ℃", the heating will automatically stop to prevent the heating element from being damaged due to the constant heating of the chamber And there are prompts for the cause of the fault and alarm prompts
12. Among similar products, the gas cut-off protection and prompt function can maximize the protection of TCD tungsten wire and chromatographic column from damage.
13. It has a wide range of fault self diagnosis functions, 36 types of self diagnosis information, and can display the cause and handling methods of faults at any time.
14. Stable pneumatic system:
(1) The carrier gas flow rate adopts a dual stability design of first stabilizing the pressure and then stabilizing the current;
(2) Accurate pneumatic control valve components with high reproducibility and stability.
15. Multiple injection methods are available:
(1) Fill the column head for injection;
(2) Filling column gasification injection;
(3) Capillary diversion/non diversion injection: back pressure valve control technology, linear diversion;
(4) Six way valve gas injection;

(5) Automatic headspace injection;

Temperature control indicators:
1) Column box: Room temperature+5 ℃ -400 ℃ Accuracy: 0.1 ℃ Display accuracy up to 0.01 ℃
2) Injector: Room temperature+5 ℃ -400 ℃ Accuracy: 0.1 ℃ Display accuracy up to 0.01 ℃
3) Detector: Room temperature+5 ℃ -400 ℃ Accuracy: 0.1 ℃ Display accuracy up to 0.01 ℃
4) Column temperature box volume: 248 * 248 * 260MM
5) Program temperature rise order: fifth order linear range rise
6) Program heating rate: 0.1 ℃~40 ℃ (increments of 0.1 ℃)
7) Constant temperature holding time for each stage: 0~9999.9min (increments of 0.1min)

Detector technical specifications (universal configuration includes FID or TCD, or both):

detector

Sensitivity/Sensitivity

noise

drift

linear

characteristic

FID

Mf ≤ 1 × 10-11 g/s (benzene)

≤ 0.02mV

≤ 0.15mV/h

≥107

Circular collection electrode, corundum ceramic nozzle

TCD

S ≥ 3000mV. ml/mg (benzene)

≤ 0.02mV

≤ 0.15mV/h

≥105

Imported rhenium tungsten wire, constant current power supply

ECD

M≤1×10-13g/ml(r-666)

≤ 0.02mV

≤ 0.15mV/h

≥104

High temperature resistant Ni63 radioactive source

FPD

Mp≤2×10-11g/sec(1605)

Ms ≤ 5 × 10-11g/sec (thiophene)

≤ 0.02mV

≤ 0.15mV/h

≥103

Single flame design, suitable for residual analysis

NPD

Mf ≤ 5 × 10-12g/s (azobenzene)

Mf≤5×10-12g/s( )

≤ 0.02mV

≤ 0.15mV/h

≥103

Imported rubidium beads suitable for residue analysis

Note: Dimensions: 660 * 460 * 465mm Weight: 60kg Input power supply: AC 220V ± 10% 50HZ 2KW