Product Introduction
The Golay Cell terahertz detector is currently more sensitive and widely used. It can effectively detect the terahertz power pumped by femtosecond laser. In order to meet the requirements of scientific researchers for testing accuracy, an increasing number of experimental tests believe that it is necessary to have a calibration device to calibrate the Golay Cell detector before testing. Shanghai Yichi Optoelectronics officially launched the Golay Cell terahertz detector calibration device.
The detection principle of Gaolaibox terahertz detector is based on the physical process of thin film absorption of spectral energy and vibration excitation of gas. The detection efficiency of this process will vary with changes in environmental conditions, such as unstable temperatures. The detection efficiency will affect the response of the detector. After prolonged use, the Gaolai box detector will cause the film to stretch; It will also affect the measurement parameters and results. In summary, the V (voltage) - W (power) curve provided by the manufacturer at the factory cannot be fully relied upon for calibrating the Koleos detector.
The excellent solution is to calibrate the Gaolai box detector directly in the user's laboratory before testing. This is the application purpose of our Gaolaihe terahertz detector calibration device.
The Gaolaibox terahertz detector calibration device is a device for on-site verification of accuracy, evaluating its stability and adjusting calibration coefficients. The calibration device for Gaolaihe terahertz detector launched by Shanghai Yichi Optoelectronics can provide maximum accuracy measurement results in different environments.
The main part of the calibration device for Gaolaibox terahertz detector is a very stable heat source with a radiation temperature of 100 ℃.
Product parameters
Temperature of radiant heat source | 100℃ |
Absolute confidence level of radiation source temperature | ±1℃ |
Temperature stability | ±0.1℃ |
Temperature drift within 15 minutes |
±0.1℃ |
Diameter of radiation source output hole |
60±2mm |
supply voltage | 90-230V |
Power frequency | 50±0.5Hz |
power | 100 |
Environmental pressure | 760*10-3 |
Operating temperature | 15℃-25℃ |
humidity | 40%-80% |
Equipment size | 260*180*120mm |
Equipment weight | 2.5kg |
moreTerahertz detection deviceRelated products
>>Golay Cell detector
>>Terahertz absolute power meter TK-100
>>Terahertz thermoelectric power meter Terahertz power meter
>>Ultra fast Asia Pacific Hertz detector
>>Terahertz electro-optic sampling detection system EOD
>>Terahertz observation card
>>Terahertz scanning Fabry Perot interferometer
>>TerahertzPyroelectric detector Terahertz pyroelectric power meter
>>Terahertz time-domain pulse detection module ABL
>>Schottky near-field terahertz detector
Address: Room 1108, No. 955 Jianchuan Road, Minhang District, Shanghai
Phone: 021-62209657 021-54843093 Fax: 021-54843093
Email: [email protected] Website: www.eachwave.com
QQ: 2920058626 WeChat: jesse-xue