Description: The Lucky XY-MW series halogen moisture analyzer adopts the principle of halogen lamp pyrolysis weight and is a fast moisture detection i
Product details
Details

XY-MW series halogen moisture analyzer,Portable moisture meter for grain

The halogen moisture analyzer, using the principle of halogen lamp pyrolysis weight, is a fast moisture detection instrument. The moisture analyzer measures the weight of the sample while the halogen lamp heating unit and moisture evaporation channel quickly dry the sample. During the drying process, the moisture analyzer continuously measures and displays the percentage of lost moisture in the sample in real time. After the drying program is completed, the final measured moisture content value is locked and displayed.

Compared with the international oven heating method, halogen heating can achieve the highest heating power in the shortest possible time, and the sample can be quickly dried at high temperatures. Its detection results have good consistency with the national standard oven method, are replaceable, and the detection efficiency is much higher than that of the oven method. Generally, the sample can be measured in just a few minutes. And the operation is simple, the testing is accurate, and it can display data such as moisture value, drying value, measurement time, temperature value, etc. And it has the function of connecting with computers and printers.

Lucky XY-MW series grain moisture meterIt can measure the moisture content of grains such as corn, rice, and soybeans,

Suggest using specification XY-105MW, standard sample 3-5g, testing conditions: standard, automatic, testing temperature: 120 ℃.

Testing time: 3-6 minutes.

Precautions for using halogen moisture analyzer:

1. Halogen moisture analyzer is used to measure the moisture content in samples, and any other use may cause harm to individuals

Damaged instrument.

2. Please read the instructions carefully before use and do not use in environments that do not meet the requirements.

3. The halogen rapid moisture analyzer is only for use by professionals who are familiar with the properties of the sample and have received training.

4. The power supply of the halogen rapid moisture analyzer is a three pin grounded socket. It is prohibited to disconnect the instrument's grounding wire or use a power supply that is not well grounded.

5. Adequate space should be ensured around the instrument to prevent heat accumulation and overheating.

6. Do not place flammable materials around the instrument as the area around the heating unit may become hot.

7. After the test is completed, due to the fact that the sample itself, heating unit, and its container will still be very hot, caution should be taken when removing the sample.

8. During the heating and drying process, the temperature of the ring-shaped heating components will reach 400 ℃. Therefore, do not open or touch the heating unit. If you need to fight

Please disconnect the power and wait until it completely cools down.

9. Be particularly careful with flammable or combustible materials, solvent containing substrates, and substrates that produce flammable or explosive gases when heated, as this

Some samples may pose a risk to human health or damage equipment. Therefore, when measuring such samples, the operating heating temperature should be sufficiently low

To prevent the formation of flames or explosives, wear protective equipment such as goggles. If you are not very familiar with the combustibility of the sample, test the sample

The quantity should be minimized as much as possible. In this case, the instrument should be supervised by a dedicated person just in case. Please conduct a risk analysis before the experiment.

10. For matrices containing toxic elements, they can only be heated and dried under well ventilated conditions.

11. A substrate that generates corrosive steam during heating and drying, and when measuring samples of this substrate, the steam will condense on the colder outer shell

Corrosion may occur, it is recommended to reduce the weight of the sample.