HI96734 (HI93734) residual chlorine and total chlorine microcomputer analyzer
The HI96734 (HI93734) residual chlorine and total chlorine microcomputer analyzer has a wide range of laboratory and on-site measurement applicability
Product details

HI96734 (HI93734) residual chlorine and total chlorine microcomputer analyzerThe upper limit is 10.00 ppm. The instrument has CAL CHECK function, and selecting NIST standard solution can verify the performance of the instrument at any time to determine whether it needs to be recalibrated. Convenient and user-friendly confirmation operation can ensure good calibration of the instrument* The positioning identification design ensures the accuracy of the positioning of the colorimetric dish in the colorimetric slot every time it is placed. The larger diameter design of the colorimetric dish facilitates the addition of samples and reagents. Excellent optical system design eliminates the need for frequent calibration of instruments. High precision measurement results, simple operation steps, waterproof performance and light source dustproof measurement system,HI96734 (HI93734) residual chlorine and total chlorine microcomputer analyzerHas a wide range of laboratory and on-site measurement applicability. The prompt information can guide daily operations, and the instrument has low battery indicator function and automatic shutdown function.

READ/TIMER function
The countdown function can ensure the accuracy of reaction time and avoid differences in reaction time caused by different user operations.
Calibration Date on Display
After calibration, the data will be automatically updated and calibration information can be accessed at any time, in compliance with ISO and GLP laboratory management requirements.

Humanized display interface, easy to operate, dual row easy to read LCD display screen
Excellent waterproof performance, suitable for both laboratory and on-site use
• Equipped with user calibration function, selecting a calibration group for calibration
EPA standard, GLP management function, automatic shutdown power-saving mode

model

HI 96734(HI93734)

Range

Residual chlorine 0.00 to 10.00 mg/L Cl2:Total chlorine 0.00 to 10.00 mg/L Cl2

Resolution

0.01 mg/L

Accuracy

±0.06mg/L @ 3.00 mg/L

EMC deviation

±0.01mg/L

Optical system

Tungsten lamp light source, narrowband filter @ 525 nm, silicon photovoltaic cell photodetector

Calibration function

CAL CHECK single point automatic calibration function

Power supply mode

1 x 9V battery; Can be used continuously for 200 hours; Automatic shutdown and power-saving function after 10 minutes of standby

Usage environment

0 to 50°C(32 to 122°F); RH max 95% non condensing

Size and weight

192 x 102 x 67 mm; 290 g

Measurement method

Refer to USEPA 330.5 and Standard Method 4500-Cl G standard methods. Residual chlorine reacts with DPD reagent and appears pale pink.