Brief introduction:
The sanitary clamp electromagnetic flowmeter adopts a new type of sanitary lining material and lining process, which meets the hygiene requirements of the food industry. At the same time, it adopts a stainless steel shell and stainless steel clamp connection, which facilitates the quick disassembly and cleaning of the electromagnetic flowmeter, making it less prone to contamination during use and effectively preventing the accumulation of residual measuring fluid in the measuring tube. It can be widely used in the production and manufacturing process of food such as mineral water, soy sauce, jam, beer, juice, rice wine, milk, as well as in the fields of hygiene, chemical engineering, etc.
1、 Introduction to sanitary clamp electromagnetic flowmeter:
The sanitary clamp electromagnetic flowmeter adopts a new type of sanitary lining material and lining process, which meets the hygiene requirements of the food industry. At the same time, it adopts a stainless steel shell and stainless steel clamp connection, which facilitates the quick disassembly and cleaning of the electromagnetic flowmeter, making it less prone to contamination during use and effectively preventing the accumulation of residual measuring fluid in the measuring tube. It can be widely used in the production and manufacturing process of food such as mineral water, soy sauce, jam, beer, juice, rice wine, milk, as well as in the fields of hygiene, chemical engineering, etc.
2、 Product features of sanitary clamp type electromagnetic flowmeter
All digital processing, strong anti-interference ability, reliable measurement, high accuracy, and a flow measurement range of up to 150:1
Ultra low EMI switching power supply, suitable for a wide range of power supply voltage changes, with good EMI resistance performance.
Adopting a 16 bit embedded microprocessor, it has fast computing speed, high accuracy, programmable low-frequency rectangular wave excitation, improved stability of flow measurement, and low power consumption.
Using SMD devices and surface mount technology, the circuit has high reliability.
There are no movable parts or flow blocking components inside the pipeline, and there is almost no additional pressure loss during measurement.
On site, the range can be modified online according to the actual needs of the user.
The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc.
High definition backlit LCD display, fully Chinese menu operation, easy to use, simple to operate, easy to learn and understand.
It has digital communication signal outputs such as RS485, RS232, Hart, and Modbus. (Optional)
It has self checking and self judging functions.
Hourly total volume recording function, recording the total flow volume in hours, suitable for time-sharing measurement system (optional)
There are three integrators inside that can display the forward cumulative amount, reverse cumulative amount, and difference cumulative amount respectively. There is also a non power outage timer inside that can record 16 power outage times. (Optional)
Infrared handheld operator, 115KHZ communication speed, all functions of long-distance non-contact operation converter (optional)
3、 Technical parameters of sanitary clamp electromagnetic flowmeter

Nominal diameter (mm)

(Special specifications can be customized)

Pipeline type: DN10 to DN3000

Insertion type: DN200~DN3000

Flow direction:

Positive, negative, net traffic

Range ratio:

150:1

Repetitive error:

± 0.1% of the measured value

Accuracy level:

Pipeline type: 0.5 level, 1.0 level

Temperature of the tested medium:

Ordinary rubber lining: -20 to+60 ℃

High temperature rubber lining: -20 to+90 ℃

PTFE lining: -30 to+100 ℃

High temperature PTFE lining: -20 to+180 ℃

Rated working pressure:

(High voltage can be customized)

DN6-DN80:≤1.6MPa

DN100-DN250:≤1.0MPa

DN300-DN1200:≤0.6MPa

Flow rate range:

0.1-15m/s

Conductivity range:

The conductivity of the measured fluid is ≥ 5 μ s/cm

Current output:

load resistance

0~10mA:0~1.5kΩ

4~20mA:0~750 kΩ

Digital frequency output:

The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the maximum current at the collector is 250mA

Power supply:

AC220V, DC24V or 3.6V batteries

Require the length of the straight pipe section

Upstream ≥ 5DN, downstream ≥ 2DN

Connection method:

The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988

Explosion proof grade:

mdIIBT4

Protection level:

IP65, Specially customized up to IP68

Environmental temperature:

-25~+60℃

Relative temperature:

5%~95%

Total power consumption:

Less than 20W


4、 Selection of sanitary clamp electromagnetic flowmeter instrument
1. Selection code:
model Explanation
HQLDE— internet traffic -□ -□
HQLDR— heat -□ -□
Path diameter 10-2200mm
Combination S Integrated type
L Split type
Electrode material M Stainless steel
T Ti (titanium)
D Ta (tantalum)
H Hastelloy alloy
P Pt platinum
N Ni nickel
A Tungsten carbide (wear-resistant)
Output method 0 No output
1 4-20mA/1-5KHz
2 4-20mA
Lining material X Rubber
F Polytetrafluoroethylene
P F46 (high temperature)
J PFA (wear-resistant)
T ceramics
On site display 0 No on-site display
1 On site display
Communication method 0 No communication
1 RS485
2 RS232
3 Mobdus
4 Hart
Grounding 0 No grounding ring
1 There is a grounding ring
2 There is a grounding electrode
Maximum traffic limit (n) Upper limit flow rate (range) m3/h
Work pressure A 0.6MPa
B 1.0 MPa
C 1.6 MPa
D 2,5 MPa
measurement accuracy 1 0.2
2 0.5
3 1
medium temperature L 0-80 degrees
H 0-150 degrees
power supplier DC 24V DC power supply
AC 220V AC power supply

5、 Selection of lining for sanitary clamp electromagnetic flowmeter:

Lining material

Performance

scope of application

chloroprene rubber

Neoprene

Good wear resistance, excellent elasticity, high tensile strength, and resistance to corrosion from low concentration acid-base salt media, but not resistant to corrosion from oxidizing media.

<80 ° C, general water, sewage, mud, slurry

polyurethane

Polyurethane

Has excellent wear resistance, but slightly inferior acid and alkali resistance.

<60 ° C, neutral and strongly worn mineral slurry, coal slurry, and mud.

PTFE

PTFE

A material with the most stable chemical properties, capable of withstanding boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali, and various organic solvents, but not resistant to chlorine trifluoride and high-temperature oxygen difluoride.

<180 ° C, strong corrosive media such as concentrated acid and alkali, sanitary media.

F46

Chemical stability, electrical insulation, lubricity, non adhesiveness, and non flammability are similar to PTFE, but F46 material has better strength, aging resistance, temperature resistance, and low-temperature flexibility than PTFE. Good adhesion to metal, better wear resistance than PTFE, with good performance
The tear resistance performance.

<180 ° C, hydrochloric acid, sulfuric acid, aqua regia, and strong oxidants, sanitary media


6、 Selection of electrode materials for sanitary clamp electromagnetic flowmeter:

material

Corrosion Resistance

316L

For nitric acid, sulfuric acid at room temperature<5%, boiling phosphoric acid, alkaline solution; Under certain pressure, media such as sulfurous acid, seawater, and acetic acid have strong corrosion resistance.

Hastelloy HB

Resistant to all concentrations of non oxidizing acids, bases, and non chlorinated hydrochloric acids such as hydrochloric acid, sulfuric acid, hydrofluoric acid, and organic acids at boiling point.

Hastelloy HC

Resistant to oxidizing acids such as nitric acid, mixed acids, or mixtures of chromic acid and sulfuric acid, as well as oxidizing salts and seawater

titanium

It can withstand corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming nitric acid), organic acids, alkalis, etc. It is not resistant to corrosion from relatively pure reducing acids (sulfuric acid, hydrochloric acid), but corrosion is greatly reduced when the acid contains oxidants (such as nitric acid and media containing Fe and Cu ions).

tantalum

It has excellent corrosion resistance similar to glass, except for hydrofluoric acid and concentrated sulfuric acid, and can withstand corrosion from almost all chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 175 ° C). It is not resistant to corrosion in alkali.


7、 Selection of caliber and flow rate for sanitary clamp electromagnetic flowmeter
Nominal diameter (mm) Measurable flow range (m3/h) Effective measurement flow range (m3/h) Nominal diameter (mm) Measurable flow range (m3/h) Effective measurement flow range (m3/h)
4 0.0135~0.4522 0.0135~0.4522 250 8.8313~2119 52.9875~1766
6 0.0305~1.0173 0.0305~1.0173 300 12.717~3052 76.302~2543
8 0.0543~1.8086 0.0543~1.8086 350 17.31~4154 103.86~3461
10 0.0142~3.3912 0.0848~2.826 400 22.61~5425 135.65~4521
15 0.0318~7.6302 0.1908~6.3585 450 28.62~6867 171.68~5722
20 0.0566~13.5648 0.3392~11.304 500 35.33~8478 211.95~7065
25 0.0883~21.195 0.5298~17.6625 600 50.87~12208 305.2~10173
32 0.1447~34.7258 0.8682~29.9382 700 69.24~16616 415.4~13847
40 0.2261~54.2592 1.3565~45.216 800 90.44~21703 542.6~18086
50 0.3533~84.78 2.1195~70.65 900 114.46~27468 686.7~22890
65 0.5970~143.28 3.5819~119.39 1000 141.3~33912 847.8~28260
80 0.9044~217.03 5.4259~180.86 1200 203.5~48833 1221~40694
100 1.413 ~339.12 8.478~282.6 1400 277~66467 1662~55389
125 2.2079~529.87 13.2468~441.56 1600 361.8~86814 2171~72345
150 3.1793~763 19.0755~635.85 1800 457.9~109874 2747~91562
200 5.652~1356 33.912~1130.4