Handheld oil fume concentration detector
The handheld oil fume concentration detector adopts OPA4110 transmittance method to develop HBD5-OPA4110TP OFog handheld oil mist concentration tester
Product details

Handheld oil fume concentration detectorcharacteristic:

  • The sample does not require pre-treatment such as extraction or separation, and does not require the preparation of reagentsrunmaintenancecostLow.
  • In the case of relatively single water pollutantsCan directly test water samples.
  • No need to calibrate the instrument, on-site testingPlug and playmeasure2-3 minutesYou can see the test values.
  • There is no harm to personal health from instruments and consumables.
  • No additional fees for consumables.
  • Low energy consumption; DC12V charger; 9V rechargeable battery.

Oil fume tester【application】:

  • Oil mist: mechanicalprocessing workshopMineral oil, heating decomposition or cracking products emitted during industrial production processes such as metal material heat treatment.
  • acid mistSulfuric acid mist and nitric acid mist in the atmosphere.
  • Wax mist: Wax mist concentration in wax spraying process;
  • SmokeVisibility of heavy fogWater mistConcentration detection
  • Oil fume: Volatile oils, organic compounds, and their decomposition or cracking products during food cooking and processing.

Haze tester【Instrument selection】:

purpose

model

Common measuring range

acid mist

HBD5-OPA4110TP-AFog

0.01-10mg/1000/1000/M3

Or transmittance 0-1.00

Mist

HBD5-OPA4110TP-OFog

0.01-10mg/1000/1000/M3

Or transmittance 0-1.00

Wax mist

HBD5-OPA4110TP-WFog

0.01-10mg/1000/1000/M3

Or transmittance 0-1.00

smoke

HBD5-OPA4110TP-smoke

0.1-100/1000mg/M3

Or transmittance 0-1.000-200Use;

lampblack

HBD5-OPA4110TP-cook

0.01-100mg/M3

Handheld oil fume concentration detector technologyParameters:

  • Measurement principleTransparency method
  • test methodDiffusion type, can choose to pump
  • Detection sensitivity 0.01mg/m3 ICPM (geometric standard deviation of 0.3u for average oil mist, corrected with 1.25 hard ester acid particles)
  • Measurement range0.01-10mg/1000/1000/M3Or transmittance 0-1.00optional
  • Measurement time1s. Professional regulations require taking the average, and the function of recording data and then averaging can be used to meet the requirements
  • measuring accuracy± 5% (relative correction particles)
  • monitor16x2 LCD liquid crystal display
  • serial communicationRS232/485
  • ambient temperature0-70
  • power supplyBattery type: Nicd × 8 can be used continuously for 1 hour, equipped with a 220-12V charger
  • sizeHandheld watch: 98X150X30mm; Sensor: D24x360 mm;
  • total weight0.7kg