Shanghai Bangwo Instrument Equipment Co., Ltd
Home>Products>Hangzhou Aihua AWA6258 three-axis vibration measuring instrument
Hangzhou Aihua AWA6258 three-axis vibration measuring instrument
Hangzhou Aihua AWA6258 three-axis vibration measuring instrument
Product details


The AWA6258 multifunctional vibration analyzer is a multi-channel handheld analyzer that uses digital signal processing technology and can simultaneously measure three-axis vibration. It has multiple frequency weights for evaluating vibrations. It can perform whole-body vibration measurement, hand transmitted vibration measurement, environmental vibration measurement, and can also perform vibration analysis1/3 OCTSpectrum analysis.


TECHNICAL INDEX

Execution standards

GB/T 23716-2009 Instruments for measuring human response to vibration (ISO 8041:2005, IDT)

GB/T 3241-2010 Acoustics - Octave and Fractional Octave Filters (IEC 61260:1995, MOD)

Standards

GB/T 10071-1988 Measurement Method for Environmental Vibration in Urban Areas;

GB/T 13441.1-2007 Mechanical Vibration and Shock - Evaluation of Human Exposure to Whole Body Vibration - Part 1: General Requirements (ISO 2631-1:1997, IDT);

GB/T 13441.2-2008 Mechanical Vibration and Shock - Evaluation of Human Exposure to Whole Body Vibration - Part 2: Vibration inside Buildings (1 Hz~80 Hz) (ISO 2631-2:2003, IDT);

GB/T 14790.1-2009 Mechanical Vibration - Measurement and Evaluation of Human Exposure to Hand transmitted Vibration - Part 1: General Requirements (ISO 5349-1:2001, IDT);

GB/T 14790.2-2014 Mechanical Vibration - Measurement and Evaluation of Human Exposure to Hand Transmitted Vibration - Part 1: Practical Guidelines for Workplace Measurements (ISO 5349-1:2001, IDT);

GB/T 50355-2005 Standard for Indoor Vibration Limits and Measurement Methods of Residential Buildings;

GB/T 50452-2008 Technical Specification for Industrial Vibration Prevention of Ancient Buildings;

JGJ/T 170-2009 Standard for Limits and Measurement Methods of Building Vibration and Secondary Radiation Noise Caused by Urban Rail Transit;

Other relevant standards, etc;

Frequency weighting and its range

(with 10-6 m/s2For reference)

VLx-y (whole body level) 70-175

VLz (whole body vertical) 80 ~ 185

Wb (z-axis, seat surface) 81-185

Wc (x-axis, seat backrest) 78-183

Wd (x, y axis, seat surface) 73-184

We (rx, ry, rz axis, seat surface) 70-168

Wj (vertical, lying down (head)) 88-185

Wk (z-axis, seat surface) 80-185

Wm (building) 70-180

Wh (arm) 70-185

Frequency range Whole body vibration measurement

VLx-y/VLz :

1.25 Hz~63 Hz(±1 dB)

1 Hz~80 Hz(±2 dB)

Wb/Wc/Wd/We/Wj/Wk:

0.63 Hz~63 Hz(±1 dB)

0.315 Hz~125 Hz(±2 dB)

0.315Hz~250Hz(+2dB~-∞)

Wm:

1.25Hz~63Hz(±1dB)

0.63Hz~125Hz(±2 dB)

0.315Hz~250Hz(+2dB~-∞)

Hand transmitted vibration measurement

Wh :

10 Hz~800 Hz(±1 dB)

5 Hz~1600 Hz(±2 dB)

VBLe :

12.5 Hz~630 Hz(±1 dB)

8 Hz~1000 Hz(±2 dB)

Low frequency 1/3 OCT analysis 0.315 Hz~250 Hz(±1 dB)
Vibration 1/3 OCT analysis

20 Hz~2000 Hz(±5%)

2.5 Hz~2000 Hz(±12%)

Online measurement of blasting vibration

4 Hz~180 Hz(±1 dB)

Time averaged constant 1s, 8s
Time averaged method Exponential average, linear average
Main measurement indicators

Whole body vibration measurement: Max、Min、Leq,T、 5 Ln (n can be set between 1 and 99) SD、Peak、VDV、VLxyz、VLcdd、VLddk

Hand transmitted vibration measurement: Max、Min、Leq,T、Leq,4h、Leq,8h

Low frequency 1/3 OCT analysis: Max、Min、Leq,T、 5 Ln (n can be set between 1 and 99), 30 center frequency points AP、SD、 5 synthetic frequency weights (wz, wx, wm, wk, wu)

Vibration 1/3 OCT analysis: Max、Min、Leq,T、 30 center frequency points acc、vel、disp

Online measurement of blasting vibration: peak velocity and peak frequency in three directions

sampling frequency 750 Hz or 12 kHz
Statistical sampling interval 0.1s
storage capacity

Built in 32M bit Flash RAM, capable of recording up to 1024 sets of data or 81920s of results

Output interface

DC, AC RS232、USB、 Bluetooth

Working power supply 6 LR 6 alkaline or rechargeable batteries, capable of continuous use for more than 12 hours; An external DC power supply of 4 V to 6 V can also be used
work environment

Working temperature:- 10 ℃~ 50 ℃

Storage temperature:- 20 ℃~70 ℃

Relative humidity: 25% RH to 90% RH




Function selection and application

Introduction to optional functional modules

1.Whole body vibration measurement module

1)Execution standards:GB/T 23716—2009The response of the human body to vibration Measuring instrument ISO 80412005 , IDT

2)Applicable standards:GB/T 13441—2007Mechanical vibration and impact Evaluation of Human Exposure to Whole Body Vibration

3) Frequency weighting and its range10-6 m/s2For reference):

Frequency weighting

Range (dB)

Evaluation Explanation

VLx-y

70 ~ 175

Whole body level

VLz

80 ~ 185

Whole body vertical

Wb

81 ~ 185

Z-axis, seat surface

Wc

78 ~ 183

X-axis, seat backrest

Wd

73 ~ 184

x. Y-axis, seat surface

We

70 ~ 168

Rx, ry, rz axis, seat surface

Wj

88 ~ 185

Vertical, lying down position (head)

Wk

80 ~ 185

Z-axis, seat surface

Wm

70 ~ 180

building

4) Frequency range and measurement accuracy:

Analyzer function

Frequency range and measurement accuracy

Whole body vibration

Dynamic measurement

VLx-y/VLz1.25 Hz to 63 Hz (± 1dB), 1 Hz to 80 Hz (± 2 dB)

W
b/Wc/Wd/We/Wj/Wk: 0.63 Hz~63 Hz (± 1 dB), 0.315 Hz~125 Hz (± 2 dB), 0.315 Hz~250 Hz (+2 dB~- ∞)

W
m: 1.25 Hz~63 Hz (± 1 dB), 0.63 Hz~125 Hz (± 2 dB), 0.315 Hz~250 Hz (+2 dB~- ∞)

5) Time averaging method: Index averaging for 1 second , Index average 8s Linear average of 1 second

6) Main measurement indicators: Max、Min、Leq,T5 Ln(n can be set between 1 and 99) SD、Peak、VDV、VLxyzVLcddVLddk

7) Sensor parameters:

Sensor model

sensitivity

quality

Size (mm)

AWA84410

2mv/m·s-2

250g

φ205×10

8) Sampling frequency: 750 Hz

9) Statistical sampling interval: 0.1s

2. Hand transmitted vibration measurement module

1) Execution standards: GB/T 237162009 The response of the human body to vibration Measuring instrument (ISO 8041:2005 , IDT)

2) Applicable standards: GB/T 147902009 mechanical vibration Measurement and evaluation of human exposure to hand transmitted vibrations

3) Frequency weighting and its range (in 10 units)-6m/s2For reference):

frequency weighting

Range (dB)

Evaluation Description

Wh

70 ~ 185

arm

4) Frequency range and measurement accuracy:

Analyzer function

Frequency range and measurement accuracy

Hand transmitted vibration measurement

Wh: 10 Hz to 800 Hz (± 1 dB), 5 Hz to 1600 Hz (± 2 dB)
VBL
e: 12.5 Hz to 630 Hz (± 1 dB), 8 Hz to 1000 Hz (± 2 dB)

5) Time averaging method: Index averaging for 1 second , Index average 8s Linear average of 1 second Linear average of 8 seconds

6) Main measurement indicators: Max、Min、Leq,TLeq,4hLeq,8h

7) Sensor parameters:

Sensor model

sensitivity

quality

Size (mm)

AWA84152A

2mV/m·s-2

24g

20×20×20

8) Sampling frequency: 12 kHz

3. Low frequency 1/3 OCT analysis module

1) Execution standards:

GB/T 237162009 The response of the human body to vibration Measuring instrument (ISO 8041:2005 , IDT);

GB/T 32412010 electroacoustics Octave and fractional octave filters (IEC 61260:1995 , MOD);

2) Applicable standards:

GB/T 100711988 Measurement method for environmental vibration in urban areas

GB/T 134412007 Mechanical vibration and impact Evaluation of Human Exposure to Whole Body Vibration

GB/T 50355-2005 Standard for Indoor Vibration Limits and Measurement Methods of Residential Buildings

JGJ/T 170-2009 Limit values and measurement methods for building vibration and secondary radiation noise caused by urban rail transit

3) Frequency weighting and its range (in 10 units)-6m/s2For reference):

Frequency weighting

Range (dB)

Evaluation Explanation

VLx-y

70 ~ 175

Whole body level

VLz

80 ~ 185

Whole body vertical

Wd

73 ~ 184

x. Y-axis, seat surface

Wk

80 ~ 185

Z-axis, seat surface

Wm

70 ~ 180

building

4) Frequency range and measurement accuracy:

Analyzer function

Frequency range and measurement accuracy

Low frequency 1/3 OCT analysis

VLx-y/VLz1.25 Hz to 63 Hz (± 1 dB), 1 Hz to 80 Hz (± 2 dB)
W
d/Wk: 0.63 Hz~63 Hz (± 1 dB), 0.315 Hz~125 Hz (± 2dB), 0.315 Hz~250 Hz (+2 dB~- ∞)
W
m: 1.25Hz-63Hz (± 1 dB), 0.63 Hz-125 Hz (± 2 dB), 0.315 Hz-250 Hz (+2 dB~- ∞)
Low frequency 1/3 OCT analysis: 0.315 Hz to 250 Hz (± 1 dB)

5) Time averaging method: Index averaging for 1 second , Index average 8s

6) Main measurement indicators: Max、Min、Leq,T5 Ln(n can be set between 1 and 99), 30 center frequency points AP、SD、 5 synthetic frequency weights (w)zwxwmwkwu

7) Sensor parameters:

Sensor model

sensitivity

quality

Size (mm)

remarks

AWA84410

2mv/m·s-2

250g

φ205×10

Optional selection

AWA84303

40mv/m·s-2

800g

60×60×60

Optional selection

AWA14400

40mv/m·s-2

800g

60×60×60

Optional, single axis

8) Sampling frequency: 750Hz

9) Statistical sampling interval: 0.1s

10) Measurement modes: three-axis mode, four channel mode

4. Vibration 1/3 OCT analysis module

1) Execution standards: GB/T 3241-2010 Electroacoustics Octave and fractional octave filters (IEC 61260:1995 , MOD);

2) Applicable standards:

3) Frequency range and measurement accuracy: 20 Hz to 2000 Hz(±5%) 、 2.5 Hz~2000 Hz(±12%)

4) Time averaging method: Index averaging for 1 second , Index average 8s

5) Main measurement indicators: Max、Min、Leq,T30 center frequency points acc、vel、disp

6) Sensor parameters:

Sensor model

sensitivity

quality

Size (mm)

AWA84152A

2mv/m·s-2

24g

20×20×20

7) Sampling frequency: 12kHz



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!