High temperature laboratory box furnace produced by Huanao Technology
1、 Product Introduction:
The laboratory high-temperature furnace series produced by Huanao Technology has two temperatures: 1700 ° C and 1800 ° C.
The two smaller volumes for each temperature are desktop, while the larger volume is floor standing. These box type furnaces can be customized to meet the specific needs of customers, such as the tail gas catalytic combustion torch selected for the adhesive discharge process before ceramic sintering.
2、 Standard parameters:
1. Maximum operating temperature of 1700 ° C and 1800 ° C
2. Capacity 4-10 liters
3. High quality silicon molybdenum rod heating element
4. Open the door vertically to ensure that the scorching furnace door is kept away from the operator
5. The furnace adopts high-quality refractory bricks and low-energy lightweight insulation materials
6. Programmable EPC3016P1 Controller
7. Over temperature protection
8. Ethernet communication interface
9. There is a cooling fan inside the box to ensure low temperature of the outer shell
3、 Optional accessories:
1. A series of precision digital controllers with digital communication options, multi-stage programmers and data recorders, as well as digital communication interfaces
4、 Technical parameters:
model | HTF 17/5 | HTF 17/10 | HTF 18/4 | HTF 18/8 |
Maximum temperature (℃) | 1700 | 1700 | 1800 | 1800 |
Volume (L) | 5 | 10 | 4 | 8 |
Heating time (mins) | 50 | 44 | 65 | 56 |
Size: Internal height x width x depth (mm) | 158 x 150 x 225 | 232 x 200 x 225 | 140 x 140 x 190 | 210 x 190 x 190 |
Dimensions: external height x width x depth (mm) height (when the furnace door is open) | 565 x 830 x 650 (850) | 565 x 830 x 650 (850) | 565 x 830 x 650 (850) | 565 x 830 x 650 (850) |
Configuration | Desktop computer | Desktop computer |
Desktop computer | Desktop computer |
Maximum power (W) | 4050 | 5920 | 4650 | 6200 |
RS232 data communication | standard | standard | Standard | standard |
Types of thermocouples | B | B | Pt20%Rh/Pt40%Rh | Pt20%Rh/Pt40%Rh |
Weight (Kg) |
109 | 133 |
115 |
128 |
5、 Attention:
1. The maximum continuous use temperature should be 100 ℃ lower than the maximum temperature
2. The heating rate is measured under no-load operation with the temperature set at 100 ℃ below the maximum temperature
3. A chemical reaction may occur between the heating element and zirconia, which can cause the zirconia sample to change color. We can provide process guidance or replace heating elements with other models. Please consult us for details