Product Introduction
The IHF single-stage single suction fluoroplastic alloy chemical centrifugal pump (referred to as IHF centrifugal pump, also known as fluorine lined centrifugal pump due to the advanced lining fluoroplastic technology used in the pump casing) is designed and manufactured according to international standards and combined with non-metallic pump technology. The dynamic seal adopts advanced external PTFE corrugated tube mechanical seal, which has multiple layers of protection and extends the service life of the mechanical seal. For conveying media containing impurity particles, it can be equipped with a single end hard to hard (silicon carbide to silicon carbide) mechanical seal without cooling water. Therefore, when selecting, users need to consider the solid content in the medium. Practical use has shown that the pump has corrosion resistance, wear resistance, high temperature resistance, anti-aging, high mechanical strength, smooth operation, advanced and reasonable structure, strict and reliable sealing performance, and easy disassembly and maintenance.
IHF fluorine lined centrifugal pumps are widely used in the transportation of corrosive media in chemical production, chlorine water, wastewater treatment, and acid addition processes in ion membrane caustic soda projects (most of the pumps used in ion membrane caustic soda projects in China currently use our company's products), electrolyte transportation in non-ferrous metal smelting, acid washing processes in automobile manufacturing and thin plate and strip steel production lines, as well as in many industries such as pharmaceuticals, petroleum, power, electroplating, dyes, pesticides, papermaking, food, textiles, etc. They can transport strong corrosive media such as sulfuric acid, hydrochloric acid, hydrofluoric acid, nitric acid, aqua regia, strong alkali, strong oxidant, organic solvent, reducing agent, etc. of any concentration for a long time without damage. Applicable temperature:- 20 ℃ to 100 ℃.
This series of products is designed and manufactured according to international standards (ISO2858). The pump body is made of a metal shell lined with fluoroplastic, and the impeller and pump cover are made of metal inserts wrapped in fluoroplastic alloy molded to have impact resistance and corrosion resistance. The shaft seal uses advanced external corrugated tube mechanical seals, and the wear-resistant sealing surfaces are available in silicon carbide, ceramic, PTFE, and hard alloy. It has a high cost performance ratio and is widely used in the chemical industry as an anti-corrosion centrifugal pump.

Structure and Materials
IHFseries
|
|
 |
Pump body
|
steel liningF46
|
Impeller
|
Fluoroplastic alloy
|
sealing ring
|
Fluororubber orF4
|
Pump cover
|
steel liningF46
|
Machine seal cover
|
304
|
mechanical seal
|
silicon carbide/F4/hard metal
|
Bracket
|
HT200
|
Pump shaft
|
45#steel
|
|
IHF-Dseries
|
|
 |
Pump body
|
steel liningF46
|
Impeller
|
Fluoroplastic alloy
|
sealing ring
|
Fluororubber orF4
|
Pump cover
|
steel liningF46
|
Machine seal cover
|
304
|
mechanical seal
|
silicon carbide/F4/hard metal
|
|
|
Model Meaning
IHF100-80-160 (A/D)
| IH | Chemical centrifugal pump representing international standards | 160 | The nominal diameter of the impeller is 160 mm | F | Indicating that the material is fluoroplastic alloy | D | Indicating short bracket direct connection type | 100 | Indicating that the inlet diameter of the pump is 100mm | A | Indicating a modified or updated product | 80 | Indicating that the outlet diameter of the pump is 80 mm | | |
|
|
Disassembly of centrifugal pump


Specification and Parameter
Table 1: Long bracket with secondary motor Speed:n=2900r/minDesign pressure:1.6MPa
| model |
internet traffic
m3/h
|
Head lift
M
|
efficiency
%
|
npsh
m
|
Import×Export
mm
|
Motor Power
Km
|
Overall quality
Kg
| IHF25-20-125 | 3.2 | 20 | 32 | 2.5 | 25×20 | 1.1 | 75 | IHF25-20-250 | 3.6 | 80 | 18 | 2.5 | 25×20 | 7.5 | 225 | IHF32-20-125 | 3.2 | 20 | 32 | 2.5 | 32×20 | 1.1 | 75 | IHF40-25-125 | 6.3 | 20 | 30 | 2.5 | 40×25 | 1.5 | 75 | IHF40-25-160 | 6.3 | 32 | 30 | 3 | 40×25 | 3 | 124 | IHF40-25-200 | 6.3 | 50 | 20 | 3 | 40×25 | 5.5 | 170 | IHF40-32-250 | 6.3 | 80 | 20 | 5 | 40×32 | 11 | 255 | IHF50-32-125 | 12.5 | 20 | 52 | 3.2 | 50×32 | 2.2 | 110 | IHF50-32-160 | 12.5 | 32 | 47 | 3.2 | 50×32 | 4 | 135 | IHF50-32-200 | 12.5 | 50 | 40 | 3.2 | 50×32 | 7.5 | 180 | IHF50-32-250 | 12.5 | 80 | 34 | 5 | 50×32 | 11 | 255 | IHF65-50-125 | 25 | 20 | 61 | 3.5 | 65×50 | 3 | 135 | IHF65-50-160 | 25 | 32 | 56 | 3.5 | 65×50 | 5.5 | 155 | IHF65-40-200 | 25 | 50 | 51 | 3.5 | 65×40 | 11 | 210 | IHF65-40-250 | 25 | 80 | 48 | 3.5 | 65×40 | 18.5 | 360 | IHF80-65-125 | 50 | 20 | 65 | 4 | 80×65 | 5.5 | 195 | IHF80-65-160 | 50 | 32 | 64 | 4 | 80×65 | 11 | 228 | IHF80-50-200 | 50 | 50 | 63 | 4 | 80×50 | 15 | 250 | IHF80-50-250 | 50 | 80 | 56 | 4.5 | 80×50 | 30 | 480 | IHF100-80-125 | 100 | 20 | 65 | 4.5 | 100×80 | 11 | 245 | IHF100-80-160 | 100 | 32 | 70 | 5 | 100×80 | 15 | 250 | IHF100-65-200 | 100 | 50 | 68 | 5 | 100×65 | 30 | 480 | IHF100-65-250 | 100 | 80 | 65 | 5 | 100×65 | 45 | 630 | IHF125-80-160 | 160 | 32 | 64 | 5 | 125×80 | 30 | 460 | IHF125-100-200 | 200 | 50 | 65 | 6 | 125×100 | 55 | 660 | IHF125-100-250 | 200 | 80 | 68 | 6 | 125×100 | 75 | 850 | Note: If the performance parameters you require exceed the range of this table, our company can adjust them according to your requirements. | Table 2: Long bracket with four stage motor Speed:n=1450r/minDesign pressure:1.6MPa | model |
internet traffic
m3/h
|
lift
M
|
efficiency
%
|
npsh
m
|
Import×Export
mm
|
Motor Power
Km
|
Overall quality
Kg
| IHF40-32-250 | 3 | 20 | 15 | 5 | 40×32 | 1.5 | | IHF50-32-125 | 6.3 | 5 | 45 | 3.2 | 50×32 | 0.55 | | IHF50-32-160 | 6.3 | 8 | 40 | 3.2 | 50×32 | 0.55 | | IHF50-32-200 | 6.3 | 12.5 | 33 | 3.2 | 50×32 | 1.1 | | IHF50-32-250 | 6.3 | 20 | 30 | 5 | 50×32 | 1.5 | | IHF65-50-125 | 12.5 | 5 | 55 | 3.5 | 65×50 | 0.55 | | IHF65-50-160 | 12.5 | 8 | 51 | 3.5 | 65×50 | 1.1 | | IHF65-40-200 | 12.5 | 12.5 | 46 | 3.5 | 65×40 | 1.5 | | IHF65-40-250 | 12.5 | 20 | 43 | 3.5 | 65×40 | 3 | | IHF80-65-125 | 25 | 5 | 64 | 4 | 80×65 | 1.1 | | IHF80-65-160 | 25 | 8 | 62 | 4 | 80×65 | 1.5 | | IHF80-50-200 | 25 | 12.5 | 57 | 4 | 80×50 | 2.2 | | IHF80-50-250 | 25 | 20 | 51 | 4.5 | 80×50 | 5.5 | | IHF100-80-125 | 50 | 5 | 64 | 4.5 | 100×80 | 1.5 | | IHF100-80-160 | 50 | 8 | 69 | 5 | 100×80 | 2.2 | | IHF100-65-200 | 50 | 12.5 | 68 | 5 | 100×65 | 5.5 | | IHF100-65-250 | 50 | 20 | 65 | 5 | 100×65 | 7.5 | | IHF125-80-160 | 80 | 8 | 62 | 5 | 125×80 | 5.5 | | IHF125-100-200 | 100 | 12.5 | 64 | 6 | 125×100 | 11 | | IHF125-100-250 | 100 | 20 | 69 | 6 | 125×100 | 15 | | IHF150-125-250 | 200 | 20 | 65 | 5 | 150×125 | 22 | 700 | IHF150-125-315 | 200 | 32 | 63 | 5 | 150×125 | 45 | 1180 | IHF150-125-400 | 200 | 50 | 62 | 5.5 | 150×125 | 75 | 700 | IHF200-150-250 | 200 | 20 | 68 | 5.5 | 200×150 | 45 | 1180 | IHF200-150-250 | 400 | 32 | 64 | 5.5 | 200×150 | 75 | 1420 | IHF200-150-400 | 400 | 50 | 64 | 6 | 200×150 | 110 | 1420 | Note: If the performance parameters you require exceed the range of this table, our company can adjust them according to your requirements. | Table 3: Short bracket with secondary motor Speed:n=2900r/minDesign pressure:1.6MPa | model |
internet traffic
m3/h
|
lift
M
|
efficiency
%
|
npsh
m
|
Import×Export
mm
|
Motor Power
Km
|
Overall quality
Kg
| IHF50-32-125(D) | 12.5 | 20 | 52 | 3.2 | 50×32 | 3 | 90 | IHF50-32-160(D) | 12.5 | 32 | 47 | 3.2 | 50×32 | 4 | 95 | IHF50-32-200(D) | 12.5 | 50 | 40 | 3.2 | 50×32 | 7.5 | 135 | IHF65-50-125(D) | 25 | 20 | 61 | 3.5 | 65×50 | 3 | 90 | IHF65-50-160(D) | 25 | 32 | 56 | 3.5 | 65×50 | 5.5 | 125 | IHF80-65-125(D) | 50 | 20 | 65 | 4 | 80×65 | 5.5 | 125 | Note: If the performance parameters you require exceed the range of this table, our company can adjust them according to your requirements. |
|