IHFFluoroplastic sulfuric acid pump

1、 Overview of Fluoroplastic Centrifugal Pump Description:
IHF typeFluoroplastic centrifugal pumps are designed and manufactured according to international standards and combined with non-metallic pump processes. The pump body adopts a metal shell lined with perfluoroalkoxy(F46)The pump cover, impeller, and shaft sleeve are all made of metal inserts wrapped in fluoroplastic and sintered as a whole. The shaft seal adopts advanced external corrugated pipe mechanical seal, and the static ring is selected99.9%Aluminum oxide ceramic (or silicon nitride), with PTFE filling material for the moving ring, has excellent corrosion resistance, wear resistance, and sealing performance. The inlet and outlet of the pump are reinforced with cast steel bodies to enhance the pressure resistance of the pump. Actual use shows that the pump has the advantages of corrosion resistance, wear resistance, high temperature resistance, anti-aging, high mechanical strength, smooth operation, advanced and reasonable structure, strict and reliable sealing performance, easy disassembly and maintenance, and long service life.

2、 Selection of mechanical seals for fluoroplastic centrifugal pumps:
 IHFtype
The fluoroplastic centrifugal pump adopts an external PTFE corrugated tube mechanical seal, which is characterized by compensating for the radial runout of the pump shaft, a single end face seal external installation, easy loading and unloading, intuitive working state, good corrosion and wear resistance sealing performance, and multi-layer protection, extending the service life of the mechanical seal; For conveying corrosive media containing impurity particles, a single end hard to hard (silicon carbide to silicon carbide) mechanical seal without cooling water can be used. For special corrosive media such as strong alkali and hydrofluoric acid, a pressureless sintered silicon carbide seal can be used; When selecting, users need to consider the solid content in the medium and the special corrosiveness of the medium.

3、 Fluoroplastic centrifugal pump usage:
IHFThe corrosion resistance and wear resistance of fluoroplastic centrifugal pumps have been proven in practical use and widely recognized by users. Currently, they are widely used in the transportation of corrosive media in chemical production, chlorine water wastewater treatment and acid addition process in ion membrane caustic soda projects (most of the pumps used in ion membrane caustic soda projects in China currently use our company's products), electrolyte transportation in non-ferrous metal smelting, acid washing process in automobile manufacturing, as well as many industries such as pharmaceuticals, petroleum, electricity, electroplating, dyes, pesticides, papermaking, food, textiles, etc-85150Long term transportation of strong corrosive media such as sulfuric acid, hydrochloric acid, hydrofluoric acid, nitric acid, aqua regia, strong alkali, strong oxidant, organic solvent, reducing agent, etc. under temperature conditions without damage is currently one of the popular pump equipment among users.

4、 Structure and Materials:

5、 The meaning of the model:

Example:IHF50-32-125 IH: Standardized chemical centrifugal pump codeFThe main material of the pump is fluoroplastic
50
: represents the inlet diameter of the pump 32: represents the outlet diameter of the pump 125The impeller diameter of the pump is125mm

Table 1 (n=2900r/min) Model Table:

model

internet traffic

lift

efficiency

npsh

Import * Export

rotational speed

Motor Power

Overall quality

m³

m

%

m

mm

r/min

kw

kg

IHF25-20-125

2

20.5

25

2.5

25×20

2900

1.1

70

*3.6

20

32

5.5

18

46

IHF25-20-250

2

80

12

2.5

25×20

2900

7.5

225

*3.6

80

18

5.5

78

26

IHF32-20-125

2

20.5

25

2.5

32×20

2900

1.1

70

*3.6

20

32

5.5

18

46

IHF40-25-125

4

21

33

3

40×25

2900

1.5

75

6.3

20

36

8

18

38

IHF40-25-160

*6.3

32

30

3

40×25

2900

3

124

8

32

31

10

30

32

IHF40-25-200

*6.3

50

20

3

40×25

2900

5.5

170

8

50

23

10

48

30

IHF40-32-250

*6.3

80

20

5

40×32

2900

11

255

8

80

24

12

78

34

IHF50-32-125

7

22

47

3.2

50×32

2900

2.2

110

*12.5

20

52

15

16

50

IHF50-32-160

7

33

35

3.2

50×32

2900

4

135

*12.5

32

47

15

30

47

IHF50-32-200

7

51

28

3.2

50×32

2900

7.5

180

*12.5

50

40

15

49

48

IHF50-32-250

7

80

21

5

50×32

2900

11

255

*12.5

80

34

15

77

38

IHF65-50-125

15

22

46

3.5

65×50

2900

3

135

*25

20

61

35

16

67

IHF65-50-160

15

33

45

3.5

65×50

2900

5.5

155

*25

32

56

35

30

65

IHF65-40-200

15

52

35

3.5

65×50

2900

11

210

*25

50

51

35

46

48

IHF65-40-250

15

82

33

3.5

65×50

2900

18.5

360

*25

80

48

35

72

50

IHF80-65-125

35

22

52

4

80×65

2900

5.5

195

*50

20

65

60

18

70

IHF80-65-160

35

33

60

4

80×65

2900

11

228

*50

32

64

60

27

53

IHF80-50-200

35

52

55

4

80×50

2900

15

250

*50

50

63

60

45

55

IHF80-50-250

35

82

48

4.5

80×50

2900

30

480

*50

80

56

60

72

50

IHF100-80-125

65

22

62

4.5

100×80

2900

11

245

*100

20

65

120

17

68

IHF100-80-160

65

35

65

5

100×80

2900

15

250

*100

32

70

110

26

65

IHF100-65-200

65

51

62

5

100×65

2900

30

480

*100

50

68

120

43

56

IHF100-65-250

65

82

60

5

100×65

2900

45

550

*100

80

65

120

65

70

IHF125-80-160

100

38

57

5

125×80

2900

30

460

*160

32

64

180

26

52

IHF125-100-200

120

55

63

6

125×100

2900

55

660

*200

50

65

220

45

62

IHF125-100-250

120

86

54

6

125×100

2900

75

850

*200

80

68

210

65

61

Note:1*For standard specifications;Try to choose parameters that are the same or similar to those in this table. If they are not within the scope of this table, our factory will improve the impeller to achieve this

2When the flow rate at the operating point is too low, a reflux pipe should be connected to the outlet.

Table 2(n=1450r/min)Model Table:

model

internet traffic

lift

efficiency

npsh

Import * Export

rotational speed

Motor Power

m³

m

%

m

mm

r/min

kw

IHF40-32-250

*3

20

15

5

40×32

1450

1.5

4

20

20

6

19.5

30

IHF50-32-125

3.5

4.5

40

3.2

50×32

1450

0.55

*6.3

5

45

7.5

4

42

IHF50-32-160

3.5

9

30

3.2

50×32

1450

0.55

*6.3

8

40

7.5

7.5

40

IHF50-32-200

3.5

12.8

22

3.2

50×32

1450

1.1

*6.3

12.5

33

7.5

12.3

40

IHF50-32-250

3.5

20

15

5

50×32

1450

1.5

*6.3

20

30

7.5

19.3

32

IHF65-50-125

7.5

3.8

40

3.5

65×50

1450

0.55

*12.5

5

55

17.5

4

61

IHF65-50-160

7.5

8.8

40

3.5

65×50

1450

1.1

*12.5

8

51

17.5

7.5

60

IHF65-40-200

7.5

13

30

3.5

65×40

1450

1.5

*12.5

12.5

46

17.5

11.5

42

IHF65-40-250

7.5

20.5

28

3.5

65×40

1450

3

*12.5

20

43

17.5

18

45

IHF80-65-125

17.5

5.5

50

4

80×65

1450

1.1

*25

5

64

30

4.5

68

IHF80-65-160

17.5

8.3

58

4

80×65

1450

1.5

*25

8

62

30

6.8

50

IHF80-50-200

17.5

13

48

4

80×50

1450

2.2

*25

12.5

57

30

11.3

48

IHF80-50-250

17.5

20.5

43

4.5

80×50

1450

5.5

*25

20

51

30

11.3

45

IHF100-80-125

32.5

5.5

60

4.5

100×80

1450

1.5

*50

5

64

60

4.3

65

IHF100-80-160

32.5

8.8

62

5

100×80

1450

2.2

*50

8

69

55

6.5

62

IHF100-65-200

32.5

12.8

62

5

100×65

1450

5.5

*50

12.5

68

60

10.8

56

IHF100-65-250

32.5

20.5

60

5

100×65

1450

5.5

*50

20

65

60

16.3

70

IHF125-80-160

50

9.5

55

5

125×80

1450

5.5

*80

8

62

90

6.5

50

IHF125-100-200

60

13.8

60

6

125×100

1450

11

*100

12.5

64

110

11.3

60

IHF125-100-250

60

21

53

6

125×100

1450

15

*100

20

69

120

19

71

IHF150-125-250

120

22

60

5

150×125

1450

22

*200

20

65

240

18

64

IHF150-125-315

120

35

54

5

150×125

1450

45

*200

32

63

240

30

62

IHF150-125-400

120

55

50

5.5

150×125

1450

75

*200

50

62

240

47

62

IHF200-150-250

240

22

60

5.5

200×150

1450

45

*400

20

68

480

17

62

IHF200-150-315

240

36

55

5.5

200×150

1450

75

*400

32

64

480

29

63

IHF200-150-400

240

55

52

6

200×150

1450

110

*400

50

64

480

46

64

Note:1*For standard specifications;Try to choose parameters that are the same or similar to those in this table. If they are not within the scope of this table, our factory will improve the impeller to achieve this.
2
When the flow rate at the operating point is too low, a reflux pipe should be connected to the outlet.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!