Main technical parameters:
1)Power input: three-phase AC380V+10% 50Hz 30KVA;
2)Control the output current and power factor through a combination of circuit breaker switches;
3)Manually adjust the voltage output;
4)Digital display of output voltage, current, and power factor;
5)This device includes three types: fluorescent lamp load, resistive load, and inductive+resistive load;
6)This device outputs 3 independent loads and can be used in conjunction with a lifespan testing machine for testing;
7)Fluorescent lamp load:
a)Load A: There are two sets of capacitors, one set is 70uF and the other set is 140uF.
b)Load B: capacitance of 7.3uF, inductance of 0.5H;
c)When unloaded: voltage adjustable from 50V to 280V
d)When loaded: output current: 1-30A; Voltage: adjustable from 80V to 275V
e)Power factor PF: adjustable from 0.3 to 0.96;
f)Power factor resolution 0.01;
8)Sensory load:
a)When unloaded: voltage adjustable from 80V to 280V
b)When loaded: output current: 1-30A; Voltage: adjustable from 80V to 275V
c)Power factor PF: adjustable from 0.3 to 0.96;
d)Power factor resolution 0.01, accuracy level 0.5, digital display;
9)Resistive load:
a)When unloaded: voltage adjustable from 80V to 280V
b)When loaded: output current: 1-30A; Voltage: adjustable from 80V to 275V
c)Power factor PF: 1;
d)Power factor resolution 0.01, accuracy level 0.5, digital display;
10)The range of the ammeter is 0.1~30.0A, the resolution is 0.1A, the accuracy is level 0.5, and it has a digital display;
11)The range of the voltmeter is 0.1~300.0V, the resolution is 0.1V, the accuracy is level 0.5, and it has a digital display;
12)Timer: 99h 99m 99s;
13)Counter: 1~999999 continuously adjustable, automatically stops when counted.
14)Equipped with overload and leakage protection functions;
15)Overall dimensions (mm): Width: 1200, Depth: 850, Height: 1800;
16)Whole machine weight: approximately 900kg;
17)Environmental temperature for use:- 15~40℃;
18)Relative temperature: (20~90)%RH。