Industrial high-temperature plastic shell pH electrode
Brief description: The electrode adopts high-quality low-noise cable, which can make the signal output length greater than 30 meters without interfere
Product details

Industrial pH electrode

Product features:

The double liquid junction structure of high temperature resistant gel dielectric and high temperature resistant solid dielectric is adopted, and the electrode can withstand 0.4MP without back pressure, without blockage; Can be directly used for sterilization measurement at a temperature of 130 ℃

Resistant to high temperature sterilization and disinfection at 120-130 ℃

No need to supplement dielectric, low maintenance required

High measurement accuracy, fast response, and good repeatability

Ag/AgCL reference electrode with silver ions

usePTFEShell, upper and lower 3/4NPT pipe threads,Easy installation

The electrode adopts high-quality low-noise cable, which can make the signal output length greater than 30 meters without interference

Technical parameters:

Measurement range:0~14pH

  • Response time: 30~60S
  • Stability: < 0.05pH, within 3 hours (voltage change of 10%)
  • Reproducibility: ≤+/- 2mv
  • Temperature measurement:- 5~130℃ (refers to the temperature range of 0-14pH, with accurate measurement and small error)
  • Sterilization temperature: ≤ one hundred and thirty
  • The biggest pressure:0.4MP
  • Shell material: Polytetrafluoroethylene
  • Electrode film thickness: High temperature resistant glass sensitive film 0.3mm

Note: The white transparent line represents the electrode (BNC) output, the thick black line represents the reference electrode, the thin black line represents the ground, and the red and yellow lines represent the temperature electrode.

electrodeUsage and maintenance

  • There is an appropriate amount of 3.3 M KCL solution in the protective bottle at the front end of the electrode. The electrode tip is soaked in it to maintain the activation of the glass bulb and liquid interface. When measuring, loosen the protective bottle, remove the electrode, and rinse with deionized water before use.
  • Before measurement, attention should be paid to throwing away the bubbles inside the glass bubble, otherwise it will cause measurement errors. During measurement, the electrode should be stirred in the test solution and placed still to accelerate the response.
  • Check if the joint is dry and clean. If there is any contamination, it needs to be wiped clean and dried before use.
  • It is recommended to use the two-point method to calibrate the electrode, usually by first calibrating the position with pH 6.86 buffer solution, and then determining the slope with pH 4.01 or pH 9.18 buffer solution.
  • After use, clean the electrode and insert it into a protective bottle, then tighten the bottle cap to prevent the solution from leaking out.
  • The electrode should be cleaned regularly. If the electrode glass bulb is contaminated with the PTFE ring liquid interface, the following reagents can be used for cleaning.

a. Surface active agent cleaning.

b. Calcium precipitates or metal hydroxides can be cleaned with 10% dilute hydrochloric acid.

c. Sulfide precipitation can be cleaned with 10% dilute hydrochloric acid.

d. Protein attachments can be cleaned with a mixture of 10% dilute hydrochloric acid and pepsin.