application |
Used for continuous electronic liquid level detection of liquids, such as in deep wells, boreholes, underwater, containers, or wastewater systems. Suitable for detecting groundwater, wastewater (optional FEP cable), diesel, fuel oil. |
describe |
The pressure transmitter converts physical pressure into an electrical signal proportional to the pressure. HydroFox ® DMU 08 uses piezoelectric silicon measurement units. |
accuracy class |
Deviation (nonlinearity, hysteresis, repeatability) of relative characteristic curve (referring to IEC 60770- Limit value correction):< ± 0.35 % FSO (Range 0/100mbar to 0/400mbar<± 0.5% FSO) |
range |
Relative pressure: 0/100mbar to 0/25 bar |
operation temperature |
Medium:- 10/ +70 ℃ environment 10/ +70 ℃ Storage:- 25 / +70 ℃ Ex type:- 20 / +60 ℃ Patm0.8 – 1.1 bar |
Temperature influence |
Within the scope of compensation 0 70 ℃< 400 mbar ≤ ±1% FSO/10K |
≥400 mbar ≤ ±0.75% FSO/10K |
Dynamics |
Response time: ≤ ten |
ms material Shell: Stainless steel 316L |
Diaphragm: Stainless Steel 316L |
seal up: FKM |
Pressure transmission fluid |
silicone oil |
output signal |
4-20 mA 2-wireload resistance4 – 20 mA Rmax= (UB– U |
Bmin |
) / 0.02A Ω |
current input |
4 – 20 mA < 25 mA |
electrical protection |
Short circuit protection, reverse polarity protection Electrical connection/protection level PUR cable (protection level: IP 68) Equipped with a breathing tube for reference to atmospheric pressure |
CE certification (EMC) |
EMC Directive 2014/30/EU Attachment (optional) Threaded connection accessories |