The AgriPhenoCloud DT80 intelligent data collector can perform multifunctional and universal measurements. Its body structure is compact, sturdy, and reasonable. It can work independently as a single machine, has low energy consumption, supports USB flash drives, 18 bit accuracy, and multiple communication methods for data transmission and single machine displayDisplay function.
Intelligent Data Collection Solution
AgriPhenoCloud DT80The intelligent data collector can perform multifunctional and universal measurements. Its compact, sturdy, and reasonable body structure allows for independent operation of a single machine, with low energy consumption and support forUPlate,18Bit precision, multiple communication methods for data transmission and standalone display function.
AgriPhenoCloud DT80Can achieve up to10An independent analog input or15A universal reference analog input that supports multiple inputsSDI-12A network measurement system composed of sensors, withModbusFunction, can be used forSCADAThe system,DT80Simultaneously possessingFTP(file transfer protocol)Equipped with powerful network communication capabilities and possessing12VAdjustable output voltage to ensure the power demand of the sensor.
Multiple universal measurement channels
The sensor channel has the ability to measure analog, digital, high-speed counter input, phase encoder input, and programmable serial data, making it easy and direct to connect various forms of sensors and data measurement devices.AgriPhenoCloud DT80Can be used to collect temperature, voltage, current4-20mACircuit current, resistance, bridge, strain gauge, frequency, digital, or connected smart sensors for data acquisition. At the same time, different raw data collected can be calculated, and the raw data or calculation results can be returned to the upper computer in the form of required work units or statistical reports. By setting up plans, group collection, data recording, alarm settings, and control tasks can be achieved to meet different measurement requirements. Intelligent sensorsGPS、PLCIt can be connected to other smart devices throughDT80Two serial sensor interfaces(RS232perhapsRS422、485)Connect. Customers can choosedataTakerofCANgategiveDT80Connect, implementCANBus monitoring and data collection.
Powerful data storage and communication capabilities
Up to memory1Millions of data, users can customize memory space and form according to the size of the data, and achieve different goals with multiple independent plans. When the set memory is full, you can choose to overwrite or stop the collection. Users can choose to use alarm actions to complete data archiving, or copy data toUDisk, or transfer data throughFTPTransfer to the upper computer.
Signal communication can be achieved throughModemSupported byRS232Serial portUSBInterface, Ethernet, andUImplemented through disk ports.DT80Documents and databases can be accessed via browser through close online, remote control, Internet connection and network server. There is no need to install any special software on the upper computer, nor to send any instructions from the upper computerFTP(File Transfer Protocol)You can promptly transmit the data to your office.
Instrument characteristics | |||||||||
Ø Adopting dual channel separation technology Ø Up to 15 analog (± 50V) sensor channels Ø Can be expanded to up to 300 analog channels Ø Support SDI-12 channel (expandable to multiple sensor networks) Ø2 intelligent serial port channels Ø Can use Modbus protocol for SCADA connection ØWeb and FTP client/server browsing ØCan use USB flash drive for data collection and program transfer |
|||||||||
application area |
|||||||||
Research and teaching, agricultural research and application, meteorological stations, energy consumption monitoring, environmental monitoring, temperature monitoring, thermistors, aquaculture, building structure monitoring, strain monitoring and recording, production process monitoring, fault diagnosis, mechanical work efficiency testing and monitoring, pressure, force sensors, flow, vehicle monitoringGPS、CANgate (Optional)CANBusJ1939、0BDII |
|||||||||
Application examples |
|||||||||
Agricultural Internet of Things (Greenhouse and Multi Environmental Factor Monitoring) Water and fertilizer irrigation (water-saving and multi parameter monitoring of soil) Marine Ranch (Water Quality and Nutrients, Hydrological Monitoring and Algae, Aquaculture)
Long term monitoring of ecological environment and plant physiology (plant monitoring and growth modeling)
Civil engineering (displacement, pressure, inclination sensors) Wastewater treatment plant waste liquid monitoring (pH, temperature, flow sensors)
Coal mine water quality monitoring (water quality, conductivity, turbidity, etc.)pH、 Water temperature and level sensors High temperature testing of cars in the desert (thermocouples, radiation sensors) Research on natural degradation of building materials (temperature, humidity, rainfall, wind speed and direction, total radiation, ultraviolet radiation, thermocouple sensors) |
|
||||||||
System Introduction |
|||||||||
Display and buttons Type: LCD display, 2 lines of 16 characters, backlight; Display function: channel data, alarm information, system status; Button: Through6Press a button to view display information and operation functions; signalLEDLamp:4A signal light indicating sampling, hard disk, alarm information, and power supply respectively; Software version upgrade Upgrade software through RS232, Ethernet cable, USB data cable or USB flash drive; clock Basic resolution: 200 µ s; Accuracy: ± 1 minute per year (in an environment with a 0 ℃ value of 40 ℃), ± 4 minutes per year (in environments with -40 ℃ to 0 ℃ and 40 ℃ to 70 ℃); power supply External power supply range: 10 to 30Vdc; Built in power supply: 6Vdc, 1.2Ahr lead-acid battery; Peak power: 12W (12Vdc 1A); Average electrical loss The relationship between sampling frequency and power consumption when using a 12Vdc external power supply is shown in the following table:
basic feature Numerical shell: Zinc aluminum alloy; chi Inch:180 x 137 x 65mm; weight Quantity:1.5kg; Operating temperature:-40℃ to70℃; Operating humidity:85%Water vapor does not condense; Note: Low and high temperature environments can reduce battery life,LCDThe working temperature of the display screen is-15℃ to50℃. |
|||||||||
analog channel |
|||||||||
The DT80 has 5 analog channels and can be expanded to up to 100 analog channels. Each analog channel can be connected to a three wire or four wire input, two independent two-wire inputs, or three single ended two-wire inputs. The specific number of connections is as follows: Two wire single ended channel: 15 (up to 300 expandable); Two line differential channels: 10 (up to 200 expandable); Three wire or four wire differential channels: 5 (up to 100 extensions); Note: Expansion requires configurationCEM20Module, a module contains20A simulated channel. Basic input range The basic input voltage, current, resistance, and frequency range that DT80 can measure are as follows:
Note: The data collector has an automatic range setting function and can switch between three ranges. The basic input voltage, current, resistance, and frequency accuracy that DT80G can measure are as follows:
Note: Accuracy relative to full scale. Sampling information In order to ensure measurement accuracy and suppress the influence of noise, a line frequency period greater than 50/60Hz is integrated. Maximum sampling speed: 25Hz; Effective resolution: 18 bits; Linearity: 0.01%; Common mode rejection: 90dB; lineSexual stringing inhibition: 35dB. input Channel isolation: 100V (relay open state); Analog component isolation: 100V (photoelectric isolation); Input impedance: 100K Ω,> 100MΩ; Common mode range: ± 3.5V, or ± 35V in the 30V range Sensor excitation Simulation channel excitation: optional 250 µ A or 2.5mA precision current source, 4.5V voltage, switchable external power supply; Universal excitation: The 12V power supply (maximum 150mA) can be turned on and off to power sensors and accessories, and the 5V power supply (maximum 25mA) can be turned on and off to power analog channels. |
|||||||||
Analog sensor | |||||||||
Introduce several common sensors, but the sensors that can be connected to DT80 are not limited to the following types. thermocouple Thermocouple types: B, C, D, E, G, J, K, N, R, S, T type; Thermocouple calibration: ITS-90; RTDs RTD material type: Pt,Ni,Cu; Resistance range: 10 Ω to 10K Ω; thermistor Thermistor type: YSI400xx series; Resistance range: < 10kΩ Note 1: Other types of thermistors are also supported. Note 2: The measurement range can be expanded by parallel resistors. Single chip temperature sensor Support type: LM34-60,AD590/592,TMPxx,LM135/235/335; Strain gauges and bridge sensors Configuration: 1/4 bridge, 1/2 bridge, and full bridge; Excitation: voltage or current; 4-20mACurrent loop Internal 100 Ω or external shunt resistor. |
|||||||||
DIGITAL CHANNEL |
|||||||||
digital input/output 8 bidirectional channels Input type: 8 logic levels (maximum 20/30V); Output type: 4 field-effect transistors (maximum: 30V, 100mA), 4 logic outputs; Relay 1 direct self-locking relay (maximum: 30Vdc, 1A). |
|||||||||
counting channel |
|||||||||
Low speed counting 8-channel counter, shared with digital channel; The low-speed counting function does not work in sleep mode. Model: 32-bit; Maximum counting rate: 10Hz; Dedicated counting input 4 high-speed or 2 phase encoder inputs Model: 32-bit; Maximum counting rate: 100kHz; Input type: 2 logic level inputs (maximum ± 30V). 2 magnetic induction (maximum ± 10V) sensitive inputs (10mV). |
|||||||||
Serial channel |
|||||||||
SDI-12 Four SDI-12 channels shared with the digital channel, each SDI-12 channel can connect multiple SDI-12 sensors; Universal Serial Sensor It is very convenient to record data from sensors and data streams. Available ports: Serial sensor port (RS232, RS422, RS485) or host RS232 port; Baud rate: 300 to 115200. Note: When using a serial sensor channel, the host port cannot be used for communication. |
|||||||||
Calculation channel | |||||||||
The calculation channel can perform arithmetic, trigonometric, correlation, logical, and statistical analysis on the data collected by the data collector from analog, digital, or serial channels. |
|||||||||
call the police |
|||||||||
Condition: Below, above, within range, or outside range; Delay: optional alarm response time; Action: Digital output, transmitting information or executing any datataker command. |
|||||||||
Data Collection List |
|||||||||
Number of schedules: up to 11; Sampling interval for schedule: Each schedule has a separate sampling time interval, ranging from 10ms to days. |
|||||||||
Data Storage |
|||||||||
Built-in storage Storage space: 128MB, capable of storing approximately 10 million pieces of data (large memory space can be customized); External storage device USB 1.1, USB 2.0 and other USB flash devices. |
|||||||||
Communication panel |
|||||||||
Ethernet port Panel: 10Mbps; Protocol: TCP/IP, Modbus protocol; USBport Panel: USB1.1 (virtual communication interface); Protocol: ASCII commands; hostRS232port Speed: 300 to 115200 baud rate (default 57600); Flow control: hardware (RTS/CTS); Software (XON/XOFF): None Handshake protocol: DCD,DSR,DTR,RTS,CTS; Modem support: automatic answering and dialing; Protocol: ASCII command, TCP/IP (PPP), Modbus protocol, serial sensor; Serial sensor port Panel: RS232,RS422m,RS485; Speed: 300 to 57600 baud rate; Flow control: hardware (RTS/CTS); Software (XON/XOFF): None Protocol: Modbus protocol, serial sensor; |
|||||||||
Network Services (TCP/IP) | |||||||||
Use Ethernet port or host RS232 port Command panel: Enter the ASCII command panel of DT80 through TCP/IP; Network server: Accessing existing data and data collection status through web pages, setting up user specific display interfaces, and downloading CSV format data; Modbus server (controlled end): obtains data and data acquisition status through Modbus client; ModbusClient (main control end): frommodbusRead or write data from the devicemodbusIn the equipment; FTP server: retrieves stored data through a browser or FTP client; FTP client: Automatically downloads data to the FTP server. |
|||||||||