Shanghai Zhongrong Yidian Co., Ltd
Home>Products>Intelligent low-voltage metering device comprehensive tester
Intelligent low-voltage metering device comprehensive tester
Intelligent low-voltage metering device comprehensive tester
Product details



Main indicators
>Voltage 0-500V>current 10A/500mA/1000A
>Phase 0-360 degrees>frequency 45-65Hz
>Harmonic 2-32nd order>accuracy level 0.5/0.2

Main features
1. Equipped with a 7-inch 800 * 480 dot matrix TFT true color LCD display, with a graphical operation interface that can be operated by touch screen or buttons, and the interface display is clear and intuitive;
2. Automatic range switching function, no need for manual switching;
3. Verification methods for electric energy meters: capable of verifying single and three-phase active and reactive electronic energy meters, standard energy meters, mechanical energy meters, mechatronic energy meters, prepaid energy meters, and multifunctional energy meters, as well as measuring electric energy in four quadrants;
4. Multi parameter measurement: measures AC voltage, current, power, electrical energy, frequency, phase, power factor, and can also measure the amplitude asymmetry and phase asymmetry of voltage and current, waveform distortion, and the pulse constant of the tested meter's electrical energy;
5. Data and graphic display: It can intuitively display the measurement work status and various measurement data. Can visually display measured voltage and current waveform diagrams, voltage and current phase vector diagrams, harmonic component histograms, and secondary circuit wiring diagrams;
6. Real load measurement of comprehensive errors of low-voltage energy metering devices, as well as measurement of various parameters such as low-voltage CT transformation ratio and angle difference;
7. Waveform display and harmonic analysis: It can measure the harmonic content and amplitude below the 31st order of voltage/current, and display them in a histogram;
8. Automatically identify wiring errors in P3/P4 energy meters, indicate the incorrect wiring location, display the secondary wiring diagram and power expression, and calculate the correction factor;
9. The wiring simulation function can be used as a training tool to improve the wiring skills of on-site personnel. The instrument can obtain corresponding wiring results based on on-site data without connecting voltage and current signals;
10. Record the error curve and display a schematic diagram of the error curve;
11. Power stability measurement;
12. Load curve recording (trend recording): Select any 4 data items such as voltage/current/frequency/power/power factor for recording;
13. Function of accumulating electrical energy and conducting character tests;
14. PT/CT settings can convert secondary data into primary data;
15. Calculation of voltage and current imbalance;
16. Vector calculator, on-site calculation of voltage and current vector sum;
17. The instrument is equipped with a USB interface, which can export measurement data through a USB flash drive and manage, store, and print detection reports on the computer;
18. The instrument is equipped with an RS232 interface, which can be connected to a computer to achieve real-time data transmission function;
19. The instrument is equipped with a 485 interface to read the energy data of a multifunctional energy meter (according to the national standard 645 protocol).

Product Usage
1. Electrical parameter measurement (U/I/Φ/P/Q/S/PF/Hz);
2. Discrimination of load characteristics between inductive and capacitive circuits;
3. Test the power consumption/power consumption of electrical equipment;
4. Single and three-phase power error verification;
5. Comprehensive measurement of low-voltage measuring devices;
6. Load curve recording and online monitoring of load fluctuations;
7. Can be equipped with a high current clamp meter for power line loss management data collection;
8. Measurement of electricity quality in the power grid;
9. Check the wiring of household meters and prevent electricity theft.
Technical indicators
1. Voltage measurement: 30-500V, resolution 0.001V, accuracy ± 0.2% or ± 0.5%
2. Current measurement: 5A clamp meter (overload 5% In-200% In), accuracy ± 0.2% or ± 0.5%
500A clamp gauge (overload 5% In-120% In), accuracy ± 0.5%
3. Active power/electrical energy measurement
Clamp meter measurement: voltage 30V~500V, current 5% In~200% In, accuracy ± 0.2% or ± 0.5%
Current 500A clamp meter (overload 5% In-120% In), accuracy ± 0.5%
4. Reactive power/electrical energy measurement
Clamp meter measurement: voltage 30V~500V, current 5% In~200% In, accuracy 0.5% or ± 1.0%
Current 500A clamp meter (overload 5% In-120% In), accuracy ± 1.0%
5. Phase measurement: 0 °~359.99 °, resolution 0.01 °, accuracy 0.5 °
6. Frequency measurement: 45Hz~65Hz, resolution 0.001Hz, accuracy 0.01Hz
7. Power factor:- 1.0~0~+1.0,
8. Electric energy pulse: output pulse constant (r/kwh) pulse/kwh;
Constant input of calibrated electric energy meter (r/kwh), setting range: 1~9999999
9. Operating environment: Temperature: -15 ℃ -45 ℃, Humidity: ≤ ± 85% RH non corrosive gas
10. Power supply: PT borrowed AC 80-480V, power consumption ≤ 7.5VA
Lithium battery powered 7400mAh, working time>8 hours
11. Dimensions: 275 × 200 × 72mm, Weight: 1.5kg

Configuration Details
1. Standard configuration details:

1) 1 host
2) 3 5A clamp current transformers
3) Three 500A clamp current transformers
4) 1 USB flash drive (4G)
5) 1 set of voltage testing line
6) 1 set of multifunctional photoelectric sampler
7) 1 pulse input/output line
8) 1 power adapter
9) 1 copy of user manual
10) 1 copy of factory inspection report
11) 1 copy of factory certificate/warranty card


2. Details of optional accessories:

1) VMP02 Mini Printer
2) Backup lithium battery
3) 485 data cable
4) 20A clamp current transformer
5) 100A clamp current transformer
6) 1000A clamp current transformer
7) 2000A clamp current transformer

Note: The selection of current clamps can be configured with up to 4 sets per host, and it is advisable to have a difference of 4 times the rated current between each set of current clamps!

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!