This pump has the characteristics of compact structure, easy operation, small volume, light weight, stable performance, no need for bottom valve, and no need for injection when starting. After replacing 3-4 parts, the pump can be used to transport concentrated slurry, acid, alkali, salt and other liquids.
Performance parameters of JMZ stainless steel self-priming pump
model |
Import |
Export |
internet traffic |
lift |
Suction distance |
rotational speed |
power |
25JMZ-22 |
25 |
25 |
3 |
22 |
5 |
2960 |
1.1 |
25JMZ-30 |
25 |
25 |
3 |
30 |
6 |
2960 |
1.5 |
40JMZ-22 |
40 |
25 |
6 |
22 |
5 |
2960 |
1.5 |
40JMZ-30 |
40 |
25 |
6 |
30 |
6 |
2960 |
2.2 |
40JMZ-40 |
40 |
25 |
6 |
40 |
6 |
2960 |
3 |
50JMZ-22 |
50 |
40 |
12 |
22 |
5 |
2960 |
2.2 |
50JMZ-30T |
50 |
50 |
20 |
30 |
6 |
2960 |
4 |
50JMZ-40 |
50 |
40 |
12 |
40 |
6 |
2960 |
4 |
65JMZ-22 |
65 |
50 |
24 |
22 |
5 |
2960 |
4 |
65JMZ-30T |
65 |
65 |
30 |
30 |
6 |
2960 |
5.5 |
80JMZ-22 |
80 |
65 |
48 |
22 |
5 |
2960 |
5.5 |
80JMZ-30 |
80 |
65 |
48 |
30 |
5 |
2960 |
7.5 |
125JMZ-18 |
125 |
100 |
100 |
18 |
5 |
2960 |
15 |
Installation and disassembly of JMZ stainless steel self-priming pump
Malfunctions and Troubleshooting of JMZ Stainless Steel Self priming Pump
fault |
reason |
solution |
No liquid output |
1. The pump is not fully filled with starting fluid 2. Inhalation pipe Blockage in the flow channel of the extrusion tube or pump 3. Air leakage in the suction pipeline 4. The suction height exceeds the allowable range 5. The head used exceeds the design head 6. Transport hot ground and active media 7. Turning in the opposite direction 8. Mechanical seal leakage |
1. Fill the liquid again. (No need to inject liquid for the second start-up) 2. Remove debris 3. Inspect and replace the suction pipeline 4. Reinstall the pump according to the allowed suction height 5. Re select the pump 6. Reduce suction or use reverse flow installation 7. Correct the steering 8. Repair or replace mechanical seals |
Long self-priming time |
1,. Liquid temperature too high 2. The suction pipe is too long 3. The imported pipeline has an Ω - shaped bend 4. The outlet is submerged in liquid |
1. The liquid overflow degree drops below 40 ℃ 2. Try to shorten the pipeline as much as possible 3. Remove all Ω pipes 4. Connect the outlet to the atmosphere |
Insufficient traffic |
1. Insufficient immersion depth of the suction pipe 2. The suction pipeline is too thin or blocked by debris 3. The impeller is severely worn and corroded 4. The sealing ring has severe wear or corrosion 5. The gap between the impeller and the pump cover is too large |
1. Increase the immersion depth of the suction pipe 2. Replace the appropriate pipeline and remove debris 3. Replace the impeller with a new one 4. Replace the sealing ring with a new one 5. Reduce gaps |
Insufficient head |
1. Severe corrosion of the impeller 2. Incorrect motor configuration 3. The gap between the impeller and the pump cover is too large |
1. Replace the impeller with a new one 2. Replace the motor 3. Reduce the gap by 8 |
Bearing overheating |
1. Insufficient or excessive lubricating oil 2. The pump shaft and motor shaft are not concentric 3. Bearing damage 4. The bearing quality does not match |
1. Lubricating oil should be applied to 30-40% of the sealing chamber 2. Adjustment Make the pump shaft concentric with the motor shaft 3. Replace the bearings with new ones 4. Replace the low-noise bearing |
vibrate serious |
1. The pump shaft and motor shaft are not concentric 2. Bending of pump shaft |
1. Adjust to align the pump shaft with the motor shaft 2. Replace the shaft again |
seal leakage |
1. Insufficient spring pressure 2. Corrosion, wear, or scratches on the end of the moving or stationary ring 3. Corrosion and deformation of the damaged sealing ring 4. Foreign objects or crystallization of the medium affect the axial movement of the moving ring |
1. Adjust the compression amount of the spring or replace the spring 2. Repair or replace the dynamic or static ring 3. Replace the sealing ring with a new one 4. Remove crystals of foreign objects or media |
motor overheating |
1. The liquid has a high specific gravity and the temperature is too high 2. The mechanical seal spring is adjusted too tightly 3. Low voltage 4. Poor assembly quality, some parts experience friction, or the motor and pump are not concentric |
1. Increase the motor size 2. Adjust the compression amount of the spring again 3. Increase the voltage 4. Check the assembly quality and eliminate assembly faults |
Please provide as much as possible for ordering: 1. Model 2. Diameter 3. Head (m) 4. Flow rate 5. Motor power (KW) 6. Speed (R/min) 7. Material with accessories 8. Voltage (V)
Welcome to visit our Quandabf Pump Valve website (www.quandabf. cn) if you have any questions You can call us and we will do our best to provide you with high-quality service.