JW-BK112 Basic Surface Area and Aperture Tester
Instrument Model: JW-BK112 Principle Method: Gas Adsorption Method, Static Capacity Method
Product details
Instrument model: | JW-BK112 |
First-principles methods: | Gas adsorption method, static capacity method; |
test function: | Isothermal adsorption desorption curve; Single point and multi-point BET specific surface area; Langmuir specific surface area; Surface Area (STSA); Single point adsorption total pore volume and average pore size; Analysis of BJH mesoporous macropore volume and pore size distribution; T-plot method, AS plot method, DR method, MP method for routine analysis of micropores; Estimation of average particle size; Special function: NLDFT method for pore size distribution analysis; Accurate testing of true density; Gas adsorption capacity and adsorption heat testing; Quality input method testing; |
test gas: | Nitrogen, oxygen, hydrogen, argon, krypton, carbon dioxide, methane, etc; |
Range: | Surface area 0.0005m2/G to no upper limit, pore size 3.5 Å -5000 Å; Range of pore volume testing: 0.0001c/g to no upper limit; |
repeatability: | Specific surface area ≤ ± 1.0%, pore size ≤ 0.2 Å; |
test efficiency: | The average specific surface area is 30 minutes per sample; Mesoporous and macroporous analysis takes an average of 4-6 hours per sample; |
Analysis Station: | Two test positions, capable of degassing at the same position; |
P0 position: | Real time and accurate measurement of the saturated vapor pressure of nitrogen; |
Lifting system: | Two independent lifting systems are installed in situ at two sample testing positions, with electric control and automatic control, and do not interfere with each other; |
vacuum system: | Multi channel parallel vacuum pumping system, modular design, vacuum pumping speed fine adjustment valve system * * technology, can automatically adjust within the range of 2-200ml/s; |
vacuum pump: | Original imported mechanical vacuum pump, maximum vacuum 6.7 * 10-2Pa; |
Degassing systems: | Modular design of vacuum degassing pretreatment system for co location and cross location. Standard configuration includes 2 sets of same position degassing systems, 2 independent heating packs, and 2 sets of independent temperature control meters, all of which can be programmed for temperature control, with up to 10 heating steps; An external ectopic 4-position vacuum degassing system can also be optionally selected; |
Degassing temperature: | Room temperature -400 ℃, accuracy ± 1 ℃; |
Pressure sensor: | Imported with original packaging, 1000torr, accuracy ≤± 0.15% (reading); |
Voltage division range: | P/P0 10-4-0.998; |
pressure control: | Balanced pressure intelligent control method, pressure controllable interval<0.1KPa, adsorption pressure point can be automatically controlled; |
data acquisition: | Ethernet data collection, fast collection speed, high accuracy, compatible with Windows 7/XP 32/64 bit systems; |