Power analyzer for measuring the power conversion efficiency of motors and frequency converters

● Achieve high-level power basic accuracy of ± 0.04% rdg ±0.05%f.s.

A measurement frequency band of 200kHz, with stable amplitude and phase accuracy at high frequencies

Thoroughly achieve miniaturization/lightweighting of the body to meet high-precision measurements on site and in research laboratories

50ms high-precision and high-speed calculation of transient power, while parallel calculation of harmonic analysis, transient waveform, interference analysis, efficiency loss, and all other projects

Multiple systems can collect up to 8 synchronized data during simultaneous measurement

● Use clamp current sensors for simple power measurement

Measurement of Current and Power Balance for the New Fuel Efficiency Standard WLTP

Specific model

PW3390-01

PW3390-02 (D/A output)

PW3390-03 (D/A output, motor analysis)

The PW3390 host cannot be measured separately. Please purchase additional voltage wires and current sensors from the options according to the measurement purpose.

Motor analysis and D/A output cannot be added later, please note.

  

Performance evaluation test of new fuel efficiency standard WLTP mode

When measuring fuel efficiency according to the WLTP standard, it is required to accurately measure the current accumulation and power accumulation of the charging and discharging of various batteries in the system. The high-precision clamp current sensor and PW3390's excellent DC accuracy, as well as the 50ms interval current accumulation and power accumulation functions, effectively evaluate the fuel efficiency performance of the vehicle.

The most suitable current sensor for vehicle measurement

The high-precision sensor with clamp design can be quickly wired without cutting the wires. The temperature range for use is -40 ℃ to 85 ℃. It has excellent temperature characteristics and can achieve high-precision measurement even in the engine compartment of vehicles.

Accumulation function of current and power with different polarities

The cumulative measurement of DC is to accumulate charging power and discharging power by polarity at a sampling rate of every 500kS/s, and measure the positive direction energy, negative direction energy, and the sum of positive and negative direction energy at the time of accumulation. Even when the battery is rapidly and repeatedly charged and discharged, it can accurately measure the amount of charge and discharge.

Through external control and linkage with surrounding devices

By using an external control button, it is possible to control the start/stop of accumulation and screen copying operations. When evaluating the performance of a real vehicle, it can also be easily controlled through manual switches or connected to other devices for time.

Power measuring instrument: PW3390 that balances high precision and maneuverability

The reading error of the power analyzer PW3390 is ± 0.04%, and the full-scale error is ± 0.05%, achieving top-level power accuracy. 200kHz measurement bandwidth and smooth amplitude and phase characteristics up to high frequencies. Used together with the phase compensation function of the current sensor, it can accurately measure high-frequency and low power factor power. Very suitable for evaluating power conversion efficiency or analyzing EV/HEV inverter motors and harmonics.

Power measuring instrument: a power analyzer with rich current sensors to expand the measurement field

Current sensors that are suitable for various measurement scenarios, such as closed mouth type that emphasizes accuracy, high-precision clamp shape that emphasizes convenience, and flexible clamp shape that can measure up to AC6000A. From secondary measurement of frequency converters to high current measurement of power lines, various power analyses such as voltage, current, power, harmonics, waveform, and efficiency calculations can be achieved through this compact body.

PW3390 Power Analyzer Parameters

Measurement line Single phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, voltage 4ch, current 4ch, insulation between channels
Basic measurement items Frequency, voltage effective value, voltage average rectified effective value conversion value, voltage AC component, voltage simple average value, voltage fundamental component, voltage peak+, voltage peak -, voltage total harmonic distortion rate, voltage ripple rate, voltage imbalance rate, current effective value, current average rectified effective value conversion value, current AC component, current simple average value, current fundamental component, current peak+, current peak -, current total harmonic distortion rate, current ripple rate, current imbalance rate, active power, apparent power, power factor, voltage phase angle, current phase angle, power phase angle, positive direction current, negative direction current, sum of positive and negative direction current, positive direction electrical energy, negative direction electrical energy, Directional electrical energy, positive and negative directional electrical energy, efficiency, and loss
Current accumulation, active power accumulation

PW3390-03: Motor torque, revolutions, motor power, slip rate
harmonic measurement Number of measurement channels: 4ch, synchronous frequency range: 0.5 Hz? 5 kHz
Analysis frequency: up to 100 times
interference measurement Number of calculation channels: 1ch (choose from CH1 to CH4)
Maximum analysis frequency: 100 k/50 k/20 k/10 k/5 k/2 kHz

Motor analysis
(PW3390-03)

Number of input channels: 3ch (CH A, CH B, CH Z)
Measurement items: voltage, torque, speed, frequency, slip rate, motor power
Measurement range Voltage: 15-1500 V, 7-speed range
electric current: 0.1 A? 20 kA (the range structure may vary depending on the sensor used)
Power: 1.5000 W? 90.00 MW (automatically determined based on voltage range/current range/measurement line combination)
Frequency: 0.5 Hz? 5 kHz

Fundamental wave accuracy
(45Hz~66Hz)

Voltage: ±0.04% rdg. ±0.05% f.s.
electric current: ±0.04% rdg. ± 0.05% f.s (with additional accuracy of current sensor)
Power: ±0.04% rdg. ± 0.05% f.s (with additional accuracy of current sensor)
Synchronous frequency range 0.5 Hz? 5 kHz
frequency band DC, 0.5 Hz? 200 kHz
Data update rate 50 ms (harmonic measurement/frequency measurement: When below 45Hz, it depends on the frequency
Display update rate 200 ms (independent of internal data update rate, waveform and FFT depend on the image)
Auto save function Save to CF card at intervals (cannot use USB flash drive): OFF, 50 ms? 60 minutes, switch to 15 gears
interface USB (communication/storage), LAN, CF card, RS-232C, Synchronous control, external control
power supply AC 100? 240 V, 50/60 Hz, 140 VA
Volume and weight 340 W × 170 H × 156 D mm, 4.6 kg
attachment User manual x 1, measurement guide x 1, power cord x 1, USB cable (0.9m) x 1, input cable label x 2, D-sub connector x 1 (PW3390-02, PW3390-03)

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!