Shanghai Jinjiale Air Technology Co., Ltd
Home>Products>Jinjiale high-pressure micro fog humidifier
Jinjiale high-pressure micro fog humidifier
1. Non dripping technology 2. Proactive reminder technology 3. Diffusion absorption technology 4. Sino German technical cooperation
Product details




Jin JialeHigh pressure micro mist humidifierProduct video


Working principle of Jinjiale high-pressure micro fog humidifier

The original imported plunger pump pressurizes the purified water to around 70KG/cm2, and then sends it to the nozzle through a high-pressure thick walled copper tube. After atomization, it sprays a micro mist of 3-15 microns into the entire space. The water mist absorbs heat in the air, changes from liquid to gas, increases the humidity of the space, and achieves the goal of reducing air temperature. The entire process is an isentropic adiabatic process. High pressure mist humidifiers do not require compressed air.




Technical parameters:For mobile access, please click here):

Model JJL-802 JJL-803 JJL-804 JJL-805 JJL-807 JJL-812 JJL-81 8 JJL-821
Spray amount 1.9 liters per minute 3.0 liters per minute 3.8 liters per minute 5 liters per minute 6.8 liters per minute 12 liters per minute 17.8 liters per minute 21 liters per minute
power 1.1KW/380V 220V 1.5KW/380V 2.2KW/380V 1.1KW/220V 3.0KW/380V 3.0KW/380V 4.0KW/380V 5.5KW/380V

Number of nozzles
≤33~41 ≤52~65 ≤66~83 ≤87~108 ≤118~148 ≤208~260 ≤309~387 ≤365~456
The rated speed of the plunger pump is 1750 revolutions per minute, and the load area of a single humidifier is 100-15000 square meters.
control box Start O-12 minutes, stop 0-60 minutes, and use a combination of humidity sensor and digital controller to accurately control humidity in minutes and seconds with relative humidity of 30-90% RH
Weight 85Kg/115Kg
Volume 81OX500X 710mm (length x width x height)
The specific number of nozzles depends on the sealing effect, new (exhaust) air volume, workshop height, temperature, humidity requirements, and installation location. Free on-site viewing




Features of Jinjiale high-pressure micro fog humidifier:

1. Atomizing 1 liter of water only requires 6W of power, which is traditionalElectric humidifierOne percent is one tenth of that of centrifugal or air-water mixed cooling humidifiers

2. The humidification amount is determined by the number of nozzles, which is very suitable for humidification in large spaces with high humidity environments

3. Coordinating with workshop ventilation in summer can also achieve a cooling effect

4. In the air conditioning box, the humidification efficiency is more than 90%, which is impossible for other spray humidifiers

Product comparison chart and special features of Jinjiale products:

金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器


product accessories

金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器

金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器


Product application industry:


金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器
金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器 金嘉乐高压微雾加湿器


Product usage case:


金嘉乐高压微雾加湿器案例 金嘉乐高压微雾加湿器案例 金嘉乐高压微雾加湿器案例


金嘉乐高压微雾加湿器案例 金嘉乐高压微雾加湿器案例 金嘉乐高压微雾加湿器案例


金嘉乐高压微雾加湿器案例 金嘉乐高压微雾加湿器案例 金嘉乐高压微雾加湿器案例




Installation and precautions:

1) All pipelines in the entire system cannot use ordinary steel pipes that are prone to rusting, high-pressure seamless copper pipes, high-pressure seamless stainless steel pipes, or high-pressure rubber steel wire composite pipes, to avoid nozzle blockage by rust water.

2) It can be directly connected to the tap water pipe, but a super strong filter must be added to avoid solid particles in the water blocking the nozzle.

3) If the machine is used in cold regions, anti freezing measures should be taken; When the host is installed outdoors, rainproof measures must be taken; After use, cut off the water source and work for 5 seconds to drain the remaining water in the pump to prevent freezing damage to the high-pressure pump.

4) It is strictly prohibited to operate the water pump without water.

5) The installation height of the nozzle is recommended to be at least 2 meters above the ground and at least 0.5 meters above the ceiling of the house; On the one hand, in order to increase the time for ultrafine mist particles to evaporate and vaporize in the air, and on the other hand, to prevent ultrafine mist particles from spraying onto obstacles and producing water droplets.

6) The optimal installation height angle for the nozzle is a horizontal upward tilt of 5-15 °.

7) The pipeline connecting the nozzle should have a drop of 300MM every 100M and a fixed point every 2M; Avoid long-term use of connecting pipelines, which may cause bending and result in residual water remaining in the pipeline for a long time, forming sediment and clogging the nozzle.

8) Before starting up, please release the pressure regulating valve to the no pressure state. After starting up, slowly adjust the pressure regulating valve and observe the pressure displayed on the pressure gauge.

9) Add lubricating oil to the crankcase before the first operation of the high-pressure pump, and add it to the middle of the two horizontal lines on the oil level gauge. Never fill it up completely; The lubricating oil of the high-pressure pump needs to be replaced after the first 50 hours of operation, and then every 300 hours thereafter. Lubricating oil is made of 40 or 60 grade.





Online inquiry