Nanjing Shengchang Experimental Instrument Co., Ltd
Home>Products>KBF1200 Atmosphere Box Furnace
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13813885135
  • Address
    Room 401, Building 2, No.1 Kechuang Road, Yaohua Street, Nanjing City, Jiangsu Province
Contact Now
KBF1200 Atmosphere Box Furnace
Product Description: The KBF1200 atmosphere box furnace uses Swedish Kantar resistance wire as the heating element, adopts a double-layer shell struct
Product details

KBF1200 The atmosphere box furnace uses Swedish Kantar resistance wire as the heating element, adopts a double-layer shell structure and a Japanese Island Electric 40 segment program temperature control system, with phase-shift triggering and thyristor control. The furnace is made of alumina polycrystalline fiber material, and the double-layer furnace shell is equipped with an air cooling system, which can quickly raise and lower the temperature. It can reach 1000 degrees in 30 minutes. The shell is sealed as a whole, and the cover plate is sealed with silicone mud. The furnace door is sealed with silicone pad and equipped with a water cooling system. The gas enters and exits the back chamber after passing through the flowmeter. There are multiple furnace inlet and outlet ports with combustion nozzles, which can pass hydrogen, argon, nitrogen, oxygen, carbon monoxide, ammonia decomposition gas and other gases. The furnace can also be pre evacuated with a vacuum pump to remove the gas inside the furnace. The furnace has a balanced temperature field and surface temperature. The advantages of low temperature, fast temperature rise and fall rate, and energy saving make it suitable for universities, research institutes Ideal products for atmosphere protection sintering and atmosphere reduction in industrial and mining enterprises.



model Power kw Furnace tube size D * W * Hmm supply voltage

KBF1200-Q1

4 300*200*200 220V
KBF1200-Q2 5 300*250*250 220V
KBF1200-Q3 9 400*300*300
380V
KBF1200-Q4 15 500*400*400 380V
KBF1200-Q5 18 500*500*500 380V




(1) The surface temperature can reach up to 1420 ℃
(2) The surface is stainless steel color (very bright, to be noted when identifying by customers), will not rust, and will not fall off slag no matter how long it is used.

(3) Good resistance balance and temperature field balance

(4) Heating element: Kanthal A1 imported resistance wire from Sweden (resistance wire can be guaranteed for 2 years)




When the circuit experiences overcurrent or leakage, the circuit will automatically disconnect

This atmosphere tube furnaceapproveEquipped with communication interfaces and software, the various parameters of the furnace can be directly controlled through a computer, and the PV and SV temperature values and instrument operation on the furnace can be observed from the computer. The actual heating curve of the furnace will be drawn in real time by the computer, and the temperature data at each moment can be saved and retrieved at any time



(1) High quality high-purity alumina polycrystalline fiber solidification furnace formed by vacuum suction filtration.
(2) Adopting Japanese technology for molding.
(3) The furnace material has low heat capacity and low thermal conductivity, resulting in less heat dissipation, good insulation, and high reflectivity. Temperature field equilibrium.
(4) The furnace alumina wire is thin and long, with high temperature resistance and strong resistance to thermal expansion and contraction
(5) The furnace surface is smooth and not prone to powder loss.

(All imported electrical appliances certified by UL)

1Phase shift trigger (with soft start and current limiting function)

2. Current limiting function: No matter how the heating rate is set, the secondary current of our electric furnace is always limited to within 170A, effectively protecting the equipment. Due to the use of current limiting function, the furnace door can be opened at high temperatures. If the electric furnace you are using needs to limit the heating rate of the furnace during the heating process (for example, it is specified that the heating rate should not exceed 1400 ℃)

If the temperature exceeds 3 ℃/min, non current limiting triggers are used. The heating rate is set incorrectly or the heating rate is too fast, and the current will be affected in this caseVery large, the equipment may trip or burn out.

3. Soft start function: When starting up, the current will gradually increase, which has less impact on the heating element and is beneficial for extending the life of the heating element

4. Protection function: If the current exceeds the limit current, the trigger will automatically cut off the triggering function to cut off the current protection of the electric furnace.


1. The transformer cable is made of pure copper

2. The sound of the transformer is low

3. Transformer body temperature is low