Kunshan Lugong Precision Instrument Co., Ltd
Home>Products>LAP-S360 spray full-automatic laser particle size analyzer
LAP-S360 spray full-automatic laser particle size analyzer
Our company takes it as our responsibility to create domestically stable laser particle size instruments, with the policy of creating brands through t
Product details
Our company takes it as our responsibility to create domestically stable laser particle size instruments, with the policy of creating brands through technology, entering the market through quality, and winning the world through reputation. We are committed to creating ultra stable and cost-effective domestically produced laser particle size instruments.
In order to meet the customer's demand for the droplet size test of small spray equipment, our company has specially developed a LAP-S360 mini desktop spray laser particle size meter. The LAP-S360 adopts a unique integrated structure design and integrates the portable design concept, making the performance of the instrument more stable, thus ensuring that the instrument has superior test accuracy and test repeatability at the same time. The design range of the LAP-S360 can meet the particle size test requirements of most users in the field of spray equipment. At the same time, the LAP-S360 also adds scientific dust prevention treatment, so it can adapt to various complex test environments.


Working principle diagram of laser particle size analyzer
Scope of application:
LAP-S360 is applicable to the droplet size detection of small spray equipment such as medical atomizers, atomized drugs, various aerosols and sprays.
LAP-S360Main performance characteristics of spray laser particle size analyzer:
The LAP-S360 is compact and exquisite, achieving true portability in the field of particle size analyzers, and can be carried wherever you go.
LAP-S360 integrates the advanced integrated structure design in the field of domestic spray particle size analyzer, which will be more stable, thus ensuring the high stability of the instrument performance. At the same time, the LAP-S360 optical path also integrates advanced dust-proof and shockproof design, so no secondary adjustment of the optical path is required no matter where the instrument is moved, greatly improving the testing efficiency of customers. Unlike the spray particle size analyzer produced by a particle size analyzer manufacturer, each time the instrument moves its position, it has to manually adjust the light path, which brings a lot of trouble to the test work and greatly shortens the service life of the instrument.
New upgrade:
Changed to a brand new detector; A large Fourier lens with a diameter of 110mm, with a larger detection angle and no blind spots for testing; Equipped with calibration function, calibration is more convenient and there is no need to disassemble the test guide tube; Automatic constant power laser can ensure long-term laser non attenuation; The test results are more accurate and have higher repeatability.
Advanced optical path design:
LAP-S360 adopts the principle of full Mie scattering and a typical parallel light path design, and uses single light path multi lens technology. Its unique high-density detection unit gives LAP-S360 super strong small particle testing capabilities. LAP-S360 achieves seamless testing within a range of 0.1 μ m to 270 μ m.
High power fiber output laser:
The LAP-S360 is equipped with an imported high-power fiber output semiconductor laser, which has stable performance and a lifespan of over 25000 hours, greatly enhancing the instrument's resolution and leaving even small particles nowhere to hide.
Optical path protection:LAP-S360 has multiple protective functions, and the unique airflow protection of the instrument during testing can effectively prevent fog droplets from splashing onto the lens and affecting the testing effect and service life of the instrument. LAP-S360 effectively avoids the influence of external natural light on test results in its design, making the test results authentic and reliable.
Ultra wide range:The design range of LAP-S360 reaches 0.1 μ m~270 μ m, which can meet the particle size testing requirements of most users in the field of spray equipment.
Powerful analysis software:
LAP-S360 is equipped with a powerful analysis software for the current domestic spray particle size analyzer, which can quickly process the light scattering signals of all laser beam droplets during the test process and convert them into real-time display of particle size distribution. Thus effectively ensuring that the test results have ultra-high representativeness, this technology is in a leading position in China.
Main technical parameters:

Specification and model LAP-S360
Execution standards ISO 13320-1:1999; GB/T19077.1-2008
Range 0.1μm -360μm
Number of detector channels 60
Accuracy Error <1% (D50 value of national standard sample)
Repeatability error <1% (D50 value of national standard sample)
Injection method Open sampling
Optical path protection The instrument has multiple optical path protection functions
Laser parameters Imported fiber optic output high-power laser with λ=650nm and p>10mW
Length of measurement area 60mm
MODE Software fully automated operation
test speed <1min/time
volume 612mm*230mm*325mm
weight 10Kg


FUNCTION
Analysis Including free distribution, R-R distribution, lognormal distribution, and hierarchical statistical models, it meets the different requirements of different industries for the statistical methods of particle size of the tested samples
Statistical method Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries
Statistics Comparison Statistical comparison and analysis can be conducted on multiple test results, which can significantly compare the differences in test results at different times and under different conditions. This has strong practical significance for controlling injection conditions and injector quality
independentlyDIYDisplay Template Users can customize the data to be displayed by calculating percentages based on particle size, particle size based on percentages, or percentage based on particle size ranges, in order to meet the characterization methods of particle size testing in different industries. Distance, consistency, interval accumulation, etc
test report The test report can be exported to Word Excel、 Various forms of documents, such as images (Bmp) and text (Text), are available for viewing test reports and referencing test results in scientific articles in any situation
Multi-Language Support Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.
Intelligent operation mode Truly automatic unmanned intervention operation, without human interference, you only need to spray the test sample according to the prompts, and the repeatability of the test results is better.

Test report:


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!