Technical Parameter
Application distance measurement for natural solid surfaces without reflectors
The measurement range is 0.1-30m, up to 150m on the surface of natural objects, depending on the reflectivity of the object being measured.
Measurement accuracy ± 2mm, white surface, ± 3mm when exceeding 30 meters
Resolution 0.1mm
Repeatability ± 0.5mm
Working mode
DT (Measurement of Natural Surface); DW (measuring white surface); DF (trigger measurement)
DX (50Hz measurement only for CHT-15B type) DM (single measurement);
Time
0.16s-6s, when establishing measurement or automatic measurement mode,
0.1s, white surface DW command;
20ms, white surface DX command (only for CHT-15B type)
Laser divergence angle 0.6mrad
Laser level 2, compliant with DIN EN 60825-1:2001-11 (EC825-1) standard, ≤ 1mW (red)
Working temperature -10 ℃ -50 ℃
Storage temperature -20 ℃ -70 ℃
Data interface RS232/RS422 (convertible), baud rate 9600, ASCII format 8n1
analog output
Programmable measurement range, 4-20mA, load impedance ≤ 500 Ω,
Accuracy: ± 0.15%, temperature drift<50PPM/℃
Programmable switch output (center point and hysteresis range) with a load capacity of 0.5A
Power supply voltage 10V-30VDC, power consumption:<0.4W during standby,<1.5W during measurement
Sensor size 212 × 96 × 50mm (L × W × H)
Installation hole size 100x85mm, 4xM6
Weight 850g
Protection level IP65, aluminum shell
scope of supply Sensor (with pin socket), 2-meter long 10 core cable with hole shaped plug on one end, cable
The other end is open; User manual, parameter setting CD, 4 M6 installation screws.
Optional Profibus interface, cooling jacket, junction box, cables of different lengths, 200Hz output frequencyrate
Instruction manual download:
http://pan.baidu.com/s/1CT53g