LI-830 CO2Analyzer and LI-850 CO2/H2O analyzer, yes |
application area
|
|
main features
Easy to operate, plug and play |
Optional models
configuration |
Detecting CO2And H2O |
Detecting CO2 |
Including built-in pump and display screen |
LI-850 |
LI-830 |
Including built-in pump, without display screen |
LI-850-1 |
LI-830-1 |
Including display screen, excluding built-in pump |
LI-850-2 |
LI-830-2 |
Only analyzer, excluding built-in pump and display screen |
LI-850-3 |
LI-830-3 |
Technical Parameter
CO2measure
Range: 0~20000 μ mol/mol
Accuracy: better than 3% of the reading value (LI-830);
Better than 1.5% of the reading value (LI-850)
Calibration Drift
Zero drift (℃)-1)1:< 0.15 μmol/mol
Span drift (℃)-1)2:< 0.03 %
Total drift (℃)-1)3:< 0.4 μmol/mol @ 370 μmol/mol
RMS noise: 1s signal average,< 1 μmol/mol @ 370 μmol/mol
Sensitivity to water vapor (LI-850 only):< 0.1 μmol/mol CO2 / mmol/mol H2O
Detection limit: 1.5 μ mol/mol
H2OMeasurement (LI-850 only)
Range: 0-60 mmol/mol
Accuracy: better than 1.5% of the reading value
Calibration Drift
Zero drift (℃)-1):< 0.005 mmol/mol @ 0 mmol/mol
Span drift (℃)-1):< 0.006 mmol/mol @ 10 mmol/mol
Total drift (℃)-1):< 0.016 mmol/mol @ 10 mmol/mol
RMS noise: 1s signal average<0.01 mmol/mol @ 10 mmol/mol
Regarding CO2Sensitivity:< 0.0001 mmol/mol H2O / μmol/mol CO2
Pump (optional)
Working environment: 5~45 ℃, 0~80% RH
Storage temperature range:- 20~60 ℃
Typical flow rate: 0.75 L/min
Power: 1 W
Expected lifespan: Approximately 8000 hours of regular use
Display screen (optional)
Size: 6.7 cm (diagonal)
Resolution: 400 × 200 pixels monochrome
Power consumption:< 200 μW
Displayed variables: CO2Read value, H2O-reading value (LI-850 only), optical path temperature and air pressure
Conventional technical parameters
Output frequency: 2 Hz
Response time (T90) CO2:< 3.5s @ 0-375 μmol/mol; H2O:<3.5s @ 0-21 mmol/mol
Measurement principle: Non dispersive infrared
Traceability:
CO2: 0-3000 μ mol/mol traceable gas calibration using WMO standards, 3000-20000 μ mol/mol traceable gas calibration using EPA protocol standards
H2O (LI-850 only): Calibration using LI-610 portable dew point generator, NIST traceable
Pressure compensation range: 50-110 kPa
Maximum airflow velocity: 1 L/min
Output signal: Dual analog voltage (0-2.5 V or 0-5 V) and dual current (4-20mA)
Digital output: TTL(0-5 V)
DAC resolution: 16 bits within the user specified range
Power supply demand:
Input voltage: 12-30 VDC
After preheating (excluding pump): average 0.33A@12 VDC(4.0W)
After preheating (including pump): average 0.42A@12 VDC(5.0W)
During preheating: average 1.2A@12 VDC(14W)
Operating temperature range:- 20 ~ 45 ℃
Relative humidity range: 0-95% RH, non condensing
Size: 22.23 × 15.25 × 7.62 cm (8.75 "× 6" × 3 ")
Quality: No pump, no display screen: 1.0 kg; Pump: 0.02kg; Display screen: 0.3kg
Internal optical path volume: 14.5 mL
1Zero drift refers to the variation of measured values with temperature when the gas concentration is 0.
2Span drift refers to the residual after resetting to zero as the temperature changes.
3Total drift refers to the variation of readings with temperature without recalibration
![]() |
![]() |
Origin and Manufacturer: LI-COR Corporation, USA