satisfyIEC884-1、GB2099.1、VDE、IEC335、GB4706.1、GB5169.5、UL1694Waiting for standards
Due to fault conditions in the product, such as fault current flowing through the leakage path, overheating of components or parts, poor contact, etc., flames can be causedCan shoot nearby again
On the parts, this experiment simulates the small flames generated inside the product under fault conditions, and evaluates the fire hazard using simulation technology. For smallHeating wire for parts (or components)
Experiment or level-When the vertical combustion test method is not suitable, the needle flame test method can be used. If the sample ignites during the hot wire test ,The resulting combustion hazard situation is also
Needle flame test is required. Suitable for components and parts of electronic and electrical products, household appliances, such as terminal blocks, centrifugal switches, etcElectric rice cooker socket . . .