1. Overview
brief introduction
The Lingke series ozone generator is developed by our company based on in-depth research on advanced technologies of similar products at home and abroad, through years of exploration, innovation, and practice, using the latest technology and special high-quality materials. This product has significant characteristics such as complete specifications, pure product, easy operation, low operating costs, low failure rate, and long service life. Its comprehensive performance ranks among the leading levels in China.
Due to the presence of a large number of pathogenic pathogens such as bacteria, viruses, and insect eggs in the quality of medical wastewater, it has the characteristics of spatial pollution, acute and latent transmission, and is highly hazardous. Our company is dedicated to the development and research of ozone disinfection products. Currently, the LK series ozone generator has more than ten specifications of products. So far, the company has a large number of operational achievements across the country. The equipment is widely used in dental hospitals, dental clinics, cosmetic surgery, ophthalmology, community clinics, physical examination centers, pet hospitals and clinics, small animal husbandry laboratories, operating rooms, laboratories and other sewage treatment facilities.
2. Product Usage
(1) Structural characteristics and working principle
★ Dental Clinic Sewage TreatmentEquipment features:
1. Pipeline liquid level sensing control, equipment realizes automatic operation of pipelines with water and automatic standby without water;
2. The entire system runs automatically without the need for dedicated personnel to manage it;
3. PLC full touch control screen, with simpler operation settings and less screen burn-in;
4. No need to build a water tank, equipment comes with a sewage treatment tank, saving costs;
5. Ozone oxidation disinfection and sterilization, with a sterilization rate of up to 99% and more thorough disinfection;
6. No need to add chemical agents, safer and more hygienic operation;
★ Dental clinic sewage treatment equipmentWorking principle
Ozone disinfection, its sterilization mechanism is to destroy and oxidize the cell membrane, cytoplasm, enzyme system, and nucleic acid of microorganisms, thereby rapidly inactivating bacteria and viruses. Ozone uses electrolyzed air as raw material and has a very high killing rate against pathogenic microorganisms, bacteria, viruses, etc. contained in medical institution wastewater.
The LK small-scale medical sewage treatment equipment uses physical methods to treat sewage, without the need for adding drugs, and there will be no excessive chlorine emissions, without incurring subsequent investment costs. The entire equipment runs fully automatically without the need for personnel management and maintenance.

technological process

Specification parameters
Specification and model: LK Maximum flow rate: 1.5m3/h
Maximum suction lift: 8m Maximum lift: 25m
Operating power: ≤ 0.35KW power input: AC220V
Dimensions: Type A: 1300 * 600 * 1200Hmm (original UPVC board)
Type B: 460 × 460 × 1100Hmm (PE material+carbon steel electrostatic electrophoretic spray material)
Type C: 500 × 450 × 600Hmm (PE material+carbon steel electrostatic electrophoretic spray material)
Water inlet method: dual function of self-priming and self flowing water inlet

(II)equipment installation
Installation conditions
1. The equipment should be installed indoors, preferably avoiding direct sunlight, and the working temperature environment of the equipment should not be lower than 0 ℃.
2. There should be a 220V power socket and good ventilation at the installation site of the equipment.
3. The ground between equipment should be paved with cement or tiled as much as possible (make sure to level the ground).
Installation program and precautions
1. Installation program
As the equipment is already assembled before leaving the factory, only the position needs to be selected and the inlet and outlet water pipelines need to be connected properly during installation.
2Installation precautions
The installation location of the equipment should generally be chosen to be close to the water source and easy to operate. During installation, attention should be paid to leaving a certain amount of maintenance space for easy maintenance.
For components that have already been installed at the factory, they should be rechecked after opening the box, and loose components should be tightened.
(3) Usage and operation
Preparation and inspection before use
1. Open the device cover and check if the connection positions of each component are loose.
2. Power on the device and check if the self-priming pump and other electrical components are working properly (just tap).
3. Long term operation of an empty aircraft is strictly prohibited.
Equipment operation and usage
1. Connect the inlet and outlet pipelines of the equipment and connect them to an AC220V power supply;
2. First, start the device and enter the operating system interface, then select the control state. The running status is green, and the stopping status is red.
Manual control status: Manually start and stop the self-priming pump and disinfection pump.
Automatic control state: The equipment is controlled by the liquid level signal. When the incoming water signal is detected, the equipment starts running. When the incoming water signal is cancelled, the equipment stops after a set delay time.
Loop control state: The device is fully controlled by the set time and starts and stops intermittently.
3. When using self-priming water inlet equipment, it is necessary to add water to the built-in suction pump of the equipment;
4. The operation can only be carried out after the water intake is completed;
5. Refer to the installation diagram for equipment installation;
(4) Attention:
1. The equipment should be installed indoors, preferably avoiding direct sunlight, and the working temperature environment of the equipment should not be lower than 0 ℃.
2. During equipment operation, it is essential to ensure stable voltage.
3. Before powering on the self-priming pump, it is necessary to add water and avoid idling, as idling can easily cause damage.
When shutting down or deactivating, the device's built-in power switch should be turned off after all devices have stopped operating.
5. The equipment should be regularly inspected and checked during operation, and any abnormal conditions should be promptly addressed.
(5) Installation diagram:
LK-AType Installation Diagram






LK-BType Installation Diagram


LK-CType Installation Diagram

(6) Diagram of Operation Process for Sewage Treatment Equipment in Dental Clinic:
1Power on to enter the boot interface, click to enter the system, and enter the device operation interface.
2Entering the operation interface, there are two control systems: V8L and V9L;
(1) V8L operation interface process: Start the device to enter the operating system interface, first select the control state. The running status is green, and the stopping status is red.
A. Manual control status: Manually start and stop the self-priming pump and disinfection pump.
B. Automatic control state: The equipment is controlled by the liquid level signal. When the incoming water signal is detected, the equipment starts running. When the incoming water signal is cancelled, the equipment stops after a set delay time.
C. Loop control state: The device is fully controlled by the set time and starts and stops intermittently.
(2) V9L operation interface process: Start the device to enter the operating system interface, first select the control state. The running status is green, and the stopping status is red.
A. Manual control status: Manually start and stop the self-priming pump, disinfection pump, and lifting pump.
B. Automatic control state: The self-priming pump and disinfection pump are controlled by the liquid level signal. When the incoming water signal is detected, the equipment starts running. When the incoming water signal is cancelled, the self-priming pump and disinfection pump will be delayed and stopped according to the set delay time. The lift pump is controlled by the water tank level signal, starting at high level and stopping at low level.
C. Cycle control state: The self-priming pump and lift pump are completely controlled by the set time, with intermittent start and stop. The lift pump is controlled by the water tank level signal, starting at high level and stopping at low level.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!