LMIX22
- Sensor/magnetic ruler installation distance up to 2.0 mm
- Differential 10... 30 V-HTL or 5 V-TTL Line Driver output terminal
- Variable resolution under four fold frequency division (to be specified when ordering)
- Repetitive accuracy+/-1 increment
- Small reading head with built-in reading electronic components
- Square wave signal speed ratio output
- At high resolution, the distance from the magnetic ruler is large
- Special solution can achieve one-time flag pulse (LMIX22-007)
technical data
measuring principle |
increment |
signal output |
Speed ratio |
Resolution under four fold frequency division |
According to the ordering instructions (0.01 mm unless otherwise specified) |
Repetitive accuracy |
+/-1 increment |
System accuracy at 20 ° C, μ m |
+/-(25+20 x L) (L=measured length, meters) |
Maximum distance to magnetic ruler |
2.0 mm |
Voltage VDC |
5 VDC or 10... 30 VDC |
Error/working voltage |
5 VDC:+/-2.5%, standing wave coefficient<50mV |
Current consumption |
5 VDC: Maximum 200 mA |
Reading electronic components |
built-in |
Output level |
5 V-TTL Line Driver or 10.. 30 V_HTL |
Output track |
A, A‘,B, B‘, Z, Z‘ |
Output terminal characteristics |
Push pull, prevent continuous short circuit |
Maximum output frequency of each channel at a resolution of 10 μ m |
TTL: 100 KHz at 4.0 m/s |
Output current/frequency band |
20 mA |
Maximum operating speed |
4.0 m/s (at a resolution of 10 μ m) |
Reference zero point |
Output of Z and Z 'signals |
reference signal |
Periodic, every 5 mm |
Repetitive accuracy |
+/-1 increment |
Maximum cable length |
5V/5V-TTL = 10m |
Minimum curvature radius of signal cable |
60 mm |
Operating temperature |
-10 ... + 70 ° C (-25...+85 ° C as required) |
Storage temperature |
-25 ... + 85 °C |
Maximum air humidity |
95%, uncondensed |
Sensor mechanical data |
1.4 mm+/-0.1 mm (magnetic ruler structure R-D) |
Sensor casing |
Die cast zinc alloy |
Protection level |
IP67 |
Sensor dimensions: length x width x height |
30 mm x 12.5 mm x 25 mm |
Installation orientation |
level |
Mechanical guide rail |
nothing |
measuring principle |
increment |
signal output |
Speed ratio |
Resolution under four fold frequency division |
According to the ordering instructions (0.01 mm unless otherwise specified) |
Repetitive accuracy |
+/-1 increment |
System accuracy at 20 ° C, μ m |
+/-(25+20 x L) (L=measured length, meters) |
Maximum distance to magnetic ruler |
2.0 mm |
Voltage VDC |
5 VDC or 10... 30 VDC |
Error/working voltage |
5 VDC:+/-2.5%, standing wave coefficient<50mV |
Current consumption |
5 VDC: Maximum 200 mA |
Reading electronic components |
built-in |
Output level |
5 V-TTL Line Driver or 10.. 30 V_HTL |
Output track |
A, A‘,B, B‘, Z, Z‘ |
Output terminal characteristics |
Push pull, prevent continuous short circuit |
Maximum output frequency of each channel at a resolution of 10 μ m |
TTL: 100 KHz at 4.0 m/s |
Output current/frequency band |
20 mA |
Maximum operating speed |
4.0 m/s (at a resolution of 10 μ m) |
Reference zero point |
Output of Z and Z 'signals |
reference signal |
Periodic, every 5 mm |
Repetitive accuracy |
+/-1 increment |
Maximum cable length |
5V/5V-TTL = 10m |
Minimum curvature radius of signal cable |
60 mm |
Operating temperature |
-10 ... + 70 ° C (-25...+85 ° C as required) |
Storage temperature |
-25 ... + 85 °C |
Maximum air humidity |
95%, uncondensed |
Sensor mechanical data |
1.4 mm+/-0.1 mm (magnetic ruler structure R-D) |
Sensor casing |
Die cast zinc alloy |
Protection level |
IP67 |
Sensor dimensions: length x width x height |
30 mm x 12.5 mm x 25 mm |
Installation orientation |
level |
Mechanical guide rail |
nothing |