Sensor 851S, LVDT displacement sensor
Swiss displacement sensors are used for measuring various lengths, diameters, thicknesses, height differences, runout, concentricity, and perpendicularity. The clamping method is simple, universal, accurate in measurement, and suitable for use in processing workshops.
Advantages of PETER LVDT sensor: ·Displacement guidance adopts ball bearings to ensure high accuracy of measurement ·Good linear error within the measurement range ·Various range sensors, including vacuum lift and compressed air drive models ·Good product compatibility (Mahr, Marpos) ·Mature half bridge and LVDT technologies ensure measurement stability and accuracy ·Over 10 million cycles of service life |
 |
Characteristics of PETER sensor: ·0-10.6mm with multiple strokes ·Unified φ 8h6 clamping straight handle ·The lifting drive includes precision spring form, vacuum lifting, and compressed air drive ·Standard hard alloy measuring ball, some sensors can replace the measuring head form according to personal needs ·Friction free, ball supported sliding measurement ensures durability and repeatability ·Adjustable force measurement ·Design firmly and continuously updated |
Sensors 851S001, 851S003, 851S005, 851S007 (axial cable)
Sensors 851S002, 851S004, 851S006, 851S008 (radial cable)
A-type spring push |
B-type vacuum lift |
C-type pneumatic driven bellows seal |
D-type pneumatic drive, air gap sealed |
851S001A/003A/005A/007A
|
851S002B/004B/006B/008B
|
851S001C/003C/005C/007C
|
851S002D/004D/006D/008D
|
851S002A/004A/006A/008A
|
851S001B/003B/005B/007B
|
851S002C/004/C006C/008C
|
851S001D/003D/005D/007D
|
Technical Parameters - Same Parameters
Maximum travel distance |
4.6mm |
Measure the travel distance |
±2mm |
Supporting method |
Ball bearing |
Probe rotation |
Full journey 1 ° |
temperature range |
-10 ° C to 65 ° C, usage/storage temperature |
Installation location |
arbitrarily |
Main body diameter |
Φ8h6 |
Cable |
Polyurethane (PUR), 2m in length |
Plug |
5-line, 270 ° |
Repetitive accuracy |
0.01um |
repair |
Repackable, detachable unit |
Measuring head |
Φ 3mm hard alloy ball, M2.5 threaded connection, replaceable |
Coil type |
851S001, 851S002 |
Half bridge type |
851S003, 851S004 |
Full bridge type (LVDT) |
851S005, 851S006 |
Full Bridge Design (LVDT) compatible with Marpos |
851S007, 851S008 |
Mahr compatible |
Drive frequency |
851S001, 851S002 |
13kHz±5% |
Supply voltage |
851S001, 851S002 |
3V±0.5%RMS |
851S003, 851S004 |
5kHz±5% |
851S003, 851S004 |
3V±0.5%RMS |
851S005, 851S006 |
7.5kHz±5% |
851S005, 851S006 |
3V±0.5%RMS |
851S007, 851S008 |
20kHz±5% |
851S007, 851S008 |
5V±0.5%RMS |
sensitivity |
851S001, 851S002 |
73.75 ± 0.15mV/(V • mm) (input resistance R=2K Ω± 0.1%) |
851S003, 851S004 |
150mV/(V • mm) (input resistance R=100K Ω) |
851S005, 851S006 |
210mV/(V • mm) (input resistance R=100K Ω) |
851S007, 851S008 |
184mV/(V • mm) (input resistance is normal impedance) |
Linear error |
851S001, 851S002 |
0.25% FS ± 1000um range (20 ° C ± 1 ° C) |
851S003, 851S004 |
0.25% FS ± 1000um range (20 ° C ± 1 ° C) |
851S005, 851S006 |
0.25% FS ± 1000um range (20 ° C ± 1 ° C) |
851S007, 851S008 |
0.3% FS ± 1000um range (20 ° C ± 1 ° C) |
Different parameters
model |
Type A |
Type B |
Type C |
D-type |
Pre itinerary/default settings |
Adjustable/-1.2mm |
Adjustable/-1.2mm |
Adjustable/+2.8mm |
Adjustable/+2.8mm |
life |
More than 10 million times |
More than 10 million times |
―― |
More than 10 million times |
Protective cover |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
―― |
Upgrade/Drive |
nothing |
Vacuum lift |
Pneumatic drive |
Pneumatic drive |
Maximum pressure |
―― |
―― |
2.0bar |
6.0bar |
Sensor 851S009 (axial cable)/851S010 (radial cable)
summary
A-type spring push |
B-type vacuum lift |
C-type pneumatic drive, bellows sealed |
D-type pneumatic drive, air gap sealed |
851S009A 
851S010A
|
851S010B
|
851S010C
|
851S010D
|
Technical Parameters - Same Parameters
Maximum travel distance |
2.5mm |
Measure the travel distance |
±1mm |
Supporting method |
Ball bearing |
Probe rotation |
Full journey 1 ° |
temperature range |
-10 ° C to 65 ° C, usage/storage temperature |
Installation location |
arbitrarily |
Main body diameter |
Φ8h6 |
Cable |
Polyurethane (PUR), 2m in length |
Plug |
5-line, 270 ° |
Repetitive accuracy |
0.02um |
Drive frequency |
13kHz±5% |
Supply voltage |
3V±0.5%RMS |
Coil type |
Half bridge type |
Linear error |
0.6% FS ± 1000um range (20 ° C ± 1 ° C) |
Measuring head |
Φ 2mm hard alloy ball, non replaceable |
Pre itinerary |
Not adjustable |
sensitivity |
73.75 ± 0.15mV/(V • mm) (input resistance R=2K Ω± 0.1%) |
Different parameters
model |
Type A |
Type B |
Type C |
D-type |
life |
More than 10 million times |
More than 10 million times |
―― |
More than 10 million times |
Protective cover |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
―― |
Upgrade/Drive |
nothing |
Vacuum lift |
Pneumatic drive |
Pneumatic drive |
Maximum pressure |
―― |
―― |
1.5bar |
6.0bar |
Measurement force |
0.4N ± 50% (potential zero point) |
0.4N ± 50% (potential zero point) |
At 0.6bar, 0.6N; At 0.8 bar, 1N (potential zero) |
At 0.8 bar, 0.6N; At 1.1 bar, 1N (potential zero) |
Sensor 851S011 (axial cable)/851S012 (radial cable)
summary
A-type spring push |
B-type vacuum lift |
C-type pneumatic drive, bellows sealed |
D-type pneumatic drive, air gap sealed |
851S011A 
851S012A

|
851S011B 
851S012B

|
851S011C 
851S012C

|
851S011D 
851S012D

|
Technical Parameters - Same Parameters
Maximum travel distance |
5.0mm |
Measure the travel distance |
±2mm |
Supporting method |
Ball bearing |
Probe rotation |
Full journey 1 ° |
temperature range |
-10 ° C to 65 ° C, usage/storage temperature |
Installation location |
arbitrarily |
Main body diameter |
Φ8h6 |
Cable |
Polyurethane (PUR), 2m in length |
Plug |
5-line, 270 ° |
Repetitive accuracy |
0.01um |
Drive frequency |
13kHz±5% |
Supply voltage |
3V±0.5%RMS |
Coil type |
Half bridge type |
repair |
Repackable, detachable unit |
Measuring head |
Φ 3mm hard alloy ball, M2.5 threaded connection, replaceable |
sensitivity |
36.88 ± 0.15mV/(V • mm) (input resistance R=2K Ω± 0.1%) |
Linear error |
0.5% FS ± 2000um range (20 ° C ± 1 ° C) |
Different parameters
model |
Type A |
Type B |
Type C |
D-type |
Pre itinerary/default settings |
Adjustable/-2.25mm |
Adjustable/-2.25mm |
Adjustable/+2.25mm |
Adjustable/+2.25mm |
life |
More than 10 million times |
More than 10 million times |
―― |
More than 10 million times |
Protective cover |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
―― |
Upgrade/Drive |
nothing |
Vacuum lift |
Pneumatic drive |
Pneumatic drive |
Maximum pressure |
―― |
―― |
2.0bar |
6.0bar |
Sensors 851S013/851S014/851S015/851S016
summary
851S013 851S014
- Measurement stroke ± 2mm
- Half bridge type
- OEM mode
|
851S013
|
851S014
|
851S015 851S016
- Measurement stroke ± 2mm
- Full bridge type (LVDT)
- OEM mode
|
851S015
|
851S016
|
Technical Parameters - Same Parameters
Repetitive accuracy |
0.01um, related to external linear bearings |
Measure the travel distance |
±2mm |
Supporting method |
None/Extra |
Supply voltage |
3V±0.5%RMS |
temperature range |
-10 ° C to 65 ° C, usage/storage temperature |
Installation location |
arbitrarily |
Main body diameter |
Φ8h6 |
Cable |
Polyurethane (PUR), 2m in length |
Plug |
5-line, 270 ° |
repair |
Repackable, detachable unit |
Linear error |
0.25% FS ± 1000um range (20 ° C ± 1 ° C) |
Different parameters
Cable |
851S013 axial |
851S014 radial |
851S015 axial |
851S016 radial |
sensitivity |
73.75±0.15mV/(V•mm) (Input resistance R=2K Ω± 0.1%) |
73.75±0.15mV/(V•mm) (Input resistance R=2K Ω± 0.1%) |
150mV/(V•mm) (Input resistance R=100K Ω) |
150mV/(V•mm) (Input resistance R=100K Ω) |
Drive frequency |
13kHz±5% |
13kHz±5% |
5kHz±5% |
5kHz±5% |
Coil type |
Half bridge type |
Half bridge type |
Full bridge type (LVDT) |
Full bridge type (LVDT) |
Sensors 851S017, 851S019, 851S021 (axial cable) Sensors 851S018, 851S020, 851S022 (radial cable)
summary
A-type spring push |
B-type vacuum lift |
C-type pneumatic drive, bellows sealed |
D-type pneumatic drive, air gap sealed |
851S017A/019A/021A

851S018A/020A/022A
|
851S017B/019B/021B

851S018B/020B/022B
|
851S017C/019C/021C

851S018C/020C/022C

|
851S017D/019D/021D

851S018D/020D/022D
|
Technical Parameters - Same Parameters
Maximum travel distance |
10.6mm |
Measure the travel distance |
851S017, 851S018 |
±5mm |
set up |
851S017, 851S018 |
|
851S019, 851S020 |
±2mm |
851S019, 851S020 |
1:2 |
851S021, 851S022 |
±2mm |
851S021, 851S022 |
1:1 |
Supporting method |
Ball bearing |
Probe rotation |
Full journey 1 ° |
temperature range |
-10 ° C to 65 ° C, usage/storage temperature |
Installation location |
arbitrarily |
Main body diameter |
Φ8h6 |
Cable |
Polyurethane (PUR), 2m in length |
Plug |
5-line, 270 ° |
Repetitive accuracy |
0.02um |
Drive frequency |
13kHz±5% |
Supply voltage |
3V±0.5%RMS |
Coil type |
Half bridge type |
repair |
Repackable, detachable unit |
Measuring head |
Φ 3mm hard alloy ball, M2.5 threaded connection, replaceable |
sensitivity |
851S017, 851S018 |
Standard setting 1:10, 7.38 ± 0.02mV/(V • mm) (input resistance R=2K Ω± 0.1%) Optional settings 1:5,14.76 ± 0.04mV/(V • mm) (input resistance R=2K Ω± 0.1%) |
851S019, 851S020 |
36.88 ± 0.15mV/(V • mm) (input resistance R=2K Ω± 0.1%) |
851S021, 851S022 |
73.75 ± 0.15mV/(V • mm) (input resistance R=2K Ω± 0.1%) |
Linear error |
851S017, 851S018 |
0.9% FS ± 5000um range (20 ° C ± 1 ° C) |
851S019, 851S020 |
0.5% FS ± 2000um range (20 ° C ± 1 ° C) |
851S021, 851S022 |
0.25% FS ± 1000um range (20 ° C ± 1 ° C) |
Different parameters
model |
Type A |
Type B |
Type C |
D-type |
Pre itinerary/default settings |
851S017/851S018 |
Adjustable/-5.5mm |
Adjustable/-5.5mm |
Adjustable/+5.5mm |
Adjustable/+5.5mm |
851S019/851S020 |
Adjustable/-2.5mm |
Adjustable/-2.5mm |
Adjustable/+8mm |
Adjustable/+8mm |
851S021/851S022 |
Adjustable/-2.5mm |
Adjustable/-2.5mm |
Adjustable/+8mm |
Adjustable/+8mm |
life |
More than 10 million times |
More than 10 million times |
―― |
More than 10 million times |
Protective cover |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
FPM/FKM (Fluororubber) |
―― |
Upgrade/Drive |
nothing |
Vacuum lift |
Pneumatic drive |
Pneumatic drive |
Maximum pressure |
―― |
―― |
2.0bar |
6.0bar |
Sensors 851S023/851S024/851S025/851S026
summary
851S023 851S024
- Measurement stroke ± 2mm
- Half bridge type
- The promotion method is related to the selected attachments
|
851S023
|
851S024

|
851S025 851S026
- Measurement stroke ± 2mm
- Full bridge type (LVDT)
- The promotion method is related to the selected attachments
|
851S025

|
851S026

|
Technical Parameters - Same Parameters
Maximum travel distance |
6.0mm |
Measure the travel distance |
±2mm |
Repetitive accuracy |
0.01um |
service life |
More than 10 million times |
Probe rotation |
Full journey 1 ° |
Measuring head |
Can be installed |
Supporting method |
Ball bearing |
Supply voltage |
3V±0.5%RMS |
temperature range |
-10 ° C to 65 ° C, usage/storage temperature |
Installation location |
arbitrarily |
External dimensions |
70×14×12mm |
Cable |
Polyurethane (PUR), 2m in length |
promote |
Can be installed |
Measurement force |
1N ± 15% (zero point), optional 1.6N |
Plug |
5-line, 270 ° |
repair |
Repackable, detachable unit |
Linear error |
0.25% FS ± 1000um range (20 ° C ± 1 ° C) |
Pre itinerary default setting |
Adjustable -1.2mm |
Different parameters
Cable |
851S023 axial direction |
851S024 radial |
851S025 axial direction |
851S026 radial |
sensitivity |
73.75±0.15mV/(V•mm) (Input resistance R=2K Ω± 0.1%) |
73.75±0.15mV/(V•mm) (Input resistance R=2K Ω± 0.1%) |
150mV/(V•mm) (Input resistance R=100K Ω) |
150mV/(V•mm) (Input resistance R=100K Ω) |
Drive frequency |
13kHz±5% |
13kHz±5% |
5kHz±5% |
5kHz±5% |
Coil type |
Half bridge type |
Half bridge type |
Full bridge type (LVDT) |
Full bridge type (LVDT) |
Sensors 851S027/851S028/851S029
summary
851S027
- Measurement stroke ± 0.25mm
- Half bridge type
- Spring push
|
851S028
- Measurement stroke ± 0.25mm
- Half bridge type
- Spring push
|
851S029
- Measurement stroke ± 0.4mm
- Half bridge type
- Spring push
|

|

|

|
Technical Parameters - Same Parameters
Supporting method |
Ball bearing |
life |
More than 10 million times |
temperature range |
-10 ° C to 65 ° C, usage/storage temperature |
Installation location |
arbitrarily |
Cable |
Polyurethane (PUR), 2m in length |
Plug |
5-line, 270 ° |
promote |
nothing |
Repetitive accuracy |
0.01um |
Drive frequency |
13kHz±5% |
Supply voltage |
3V±0.5%RMS |
Coil type |
Half bridge type |
|
|
sensitivity |
73.75 ± 0.15mV/(V • mm) (input resistance R=2K Ω± 0.1%) |
Different parameters
Cable |
851S027 Axial, without push protection |
851S028 radial |
851S029 axial |
Maximum travel distance |
0.8mm |
0.8mm |
1.5mm |
Measure the travel distance |
±0.25mm |
±0.25mm |
±0.4mm |
Pre itinerary |
0.35mm |
0.35mm |
0.40mm |
Probe rotation |
Full travel 0.5 ° |
Full travel 0.5 ° |
Full journey 1.5 ° |
Measuring head |
4mm hard alloy ball |
4mm hard alloy ball |
2mm hard alloy ball |
Protective cover |
plate with nickel |
plate with nickel |
Nitrile plating |
Main body diameter |
Φ8h6 |
Φ8h6 |
Φ5h6 |
Measurement force |
0.63N ± 20% (zero potential point) |
0.63N ± 20% (zero potential point) |
0.78N ± 20% (zero potential point) |
Linear error |
0.6%FS±250um (20°C±1°C) |
0.6%FS±250um (20°C±1°C) |
0.2%FS±400um (20°C±1°C) |
851DC Sensor
851S series sensors
application |
Same as 851S series sensors |
Main body diameter |
Φ8h6 |
External dimensions |
Cable box 58 × 35 × 16mm |
Supply voltage |
5,12 or 24V (± 10%) (please specify when ordering), current consumption of 120,50 or 25mA |
signal output |
± 10V, can replace all specifications (please consult for other specifications) |
connect |
Power supply and signal output: Cable (PVC), 1m long, equipped with metal wire Sensor and cable box connection, cable (PVC), length 2m |
modular |
851S001/851S002 measurement range ± 1mm 851S009/851S010 measurement range ± 1mm 851S011/851S012 measurement range ± 2mm 851S017/851S018 measurement range ± 5mm 851S019/851S020 measurement range ± 2mm 851S021/851S022 measurement range ± 1mm |
Ordering Example |
851S001, DC sensor, supply voltage 24V: 851S001 DC24V |
Outline drawing |

|
851Mini Micro Switch
Small signal switch with high repeatability in switching positions
application |
Reference switches for precise positioning of edges and endpoints, reference settings, etc |
Cable |
Polyurethane (PUR), 1m long, equipped with metal wire |
Repetitive accuracy |
±0.001mm |
Overtravel |
1.5mm (longer overtravel can be ordered) |
Acting force |
0.7N (other values can be ordered) |
temperature range |
-20~+70 ° C, storage and usage temperature |
electric current |
50mA |
life |
More than 10 million times |
Installation location |
arbitrarily |
function |
NC (normally closed) |
Lock nut |
2 of them |
Metal wire |
2×0.14mm2 |
Main OD |
M8×0.5 |
Material Science |
Stainless steel (1.4305) |
Outline drawing |

|
|