Lighter gas component detection gas chromatograph
Gas chromatograph analysis spectrum for lighter gas component detection:
Product details

Lighter gas component detection gas chromatograph

Lighter gas component detection gas chromatographAnalyze chromatographic conditions

Chromatographic column: 50 * 0.25.0.5

Column temperature: 40

Carrier gas: N2 30min/sec

Sample injector: 150split injection

Detector: FID 150

Sample analysis: lighter gas

Instrument technical parameters:

A 320 × 240 graphic large screen is used to display both Chinese and English, with simple and intuitive parameter settings;

● Comprehensive self diagnostic function, which enables users to conveniently check the location and type of faults;

A reliable anti-interference system ensures that power fluctuations or momentary power outages will not affect the normal operation of the instrument;

Complete temperature overheating protection and platinum resistance open circuit and short circuit alarm functions to ensure that the temperature does not lose control;

● Carrier gas pressure monitoring system to achieve the function of protecting chromatographic columns, TCD, and ECD;

Adopting advanced FLASH memory system, data protection is no longer trapped by battery failure;

The highly stable and sensitive microcurrent amplification technology significantly improves the detection limit of FID;

The new thermal conductivity detector has higher sensitivity;

The instrument can be equipped with a built-in AD conversion circuit for direct digital output of chromatographic signals;

The instrument can be equipped with XS-H2000 workstation to complete all control and analysis tasks on a PC;

The instrument pneumatic system can be equipped with electronic flow display;

New pneumatic control valves ensure the repeatability of analysis parameters;

Capillary systems have split and split/non split injection modes;

● Rear door opening technology enables near room temperature operation and 9-stage programmed heating;

The instrument can be equipped with manual/automatic FID and FPD ignition devices;

Analysis spectrum:

The main gas components in lighters are methane, propane, isobutane, n-butane, isopentane, and n-pentane, with propane having a relatively high content,

打火机中燃烧气体组分分析