Linear grating ruler LS487/LS477
Linear grating ruler LS487/LS477
Product details
LS 400 series LS487 LS477
Compact shell incremental linear grating ruler
• Used for applications with limited installation space

technical parameter

LS 487

LS 477

Measurement benchmark
Linear expansion coefficient

DIADUR glass grating, grid spacing of 20µm
αtherm ≈8 x 10-⁶ K-¹(Installation method)I/II);With mounting plate:αtherm9 x10-⁶ K-¹(Installation method)III

Accuracy level*

±5 µm; ±3 µm

Measurement length ML*Unit mm

For grating rulers up to ML 1240, the installation board * is optional, while for grating rulers above ML 1340, it is mandatory

70 120 170 220 270 320 370 420 470 520 570 620 670 720

770 820 920 1240 1540 1840 2040

Reference point*

LS 4x7

LS 4x7 C

  • Magnetic stripe selection available every 50 mm
  • 1, located at the midpoint of the measured length
  • 2 reference points, each 35 mm away from the starting and ending points of the measured length (for ML)1020 mm) or 45 mm (for ML)1140 mm)

Distance encoding

Interface

1 VPP

TTL

Internal subdivision multiple*

Signal cycle

20 µm

5-fold

10-fold

20-fold

Diagnostic interface

simulation

Deadline frequency

–3 dB

160 kHz

Scanning frequency*

Edge spacing a

100 kHz

0.5 µs

50 kHz

1 µs

100 kHz

0.25 µs

50 kHz

0.5 µs

25 kHz

1 µs

50 kHz

0.25 µs

25 kHz

0.5 µs

Measure step distance

Depends on the subdivision magnification

1 µm1)

0.5 µm1)

0.25 µm1)

Electrical connection

A separate adapter cable (1 m/3 m/6 m/9 m) can be connected to the installation block

Cable length2)

150 m

100 m

No load power supply voltage

DC 5 V ±0.25 V/< 120 mA

DC 5 V ±0.25 V/< 140 mA

Movement speed

120 m/min

120 m/min

60 m/min

120 m/min

60 m/min

30 m/min

60 m/min

30 m/min

Required motion force

5 N

Vibration55 Hz to 2000 Hz
to attack11 ms
acceleration

No installation board:≤100 m/s²(EN 60068-2-6)
With installation plate, the cable outlet is on the right side:≤200 m/s²,left:100 m/s² (EN 60068-2-6)
300 m/s²(EN 60068-2-27)
Along the measurement direction≤100 m/s²

working temperature

0 °C to 50 °C

Protection levelEN 60 529

If it meets the installation instructions in the sample, it should be IP 53. If the sealed air connected to DA 400 is IP 64

weight

0.4 kg+0.5 kg/m measuring length

* Please select when placing an order
1)After 4th harmonic subdivision in subsequent electronic circuits
2)Heidenhain Cable


Product dimension diagram: