1、 Main features
1、 Durable and sturdy, with waterproof design(IP67)Designed specifically for outdoor use
2、 PCInterface(USB/Serial port)
3、 Automatic buffer recognition function
4、 Data storage and reminder function
5、 Good laboratory practices(GLP-Function)
6、 Concise and clear results display: backlightLCDdisplay
7、 automatic temperature compensation
8、 High precision measurement,0.001pH/0.1mV
9、 Stain resistant design
2、 Application
1、 drinking water
2、 cooling water/boiling water
3、 waste water
4、 Swimming Pool Water
5、 surface water
3、 Performance characteristics
1、 Maximum memory/Minimum value: can store maximum and minimum values
2、 Auto hold: Freeze and display measurement results
3、 Automatic shutdown: If not in use, the instrument will automatically shut down at the set time(0to120Minutes, automatic shutdown)
4、 Additional display:
①pHElectrodes and batteries
②Bar chart display
③Low battery display “BAT”
5Automatic temperature compensation:
①pHIn mode, temperature compensation can be automatically performed when the electrodes are connected(ATC).
②When the temperature probe is not connected, it can be manually inputted.
6pHCalibration: Automatic buffer recognition, allowing electrode data asymmetry, checked every calibrationpH
Electrode status, useLovibondStandard buffer solution is used1、2perhaps3Point calibration.
7ORPdetermination:
2Various options
① “mv”Standard oxidation-reduction potential: according toDIN 38404auxiliary word for ordinal numbers6Partial requirements, transferable
change into“mvH”;
②rHdetermination:rHThe value can be obtained by measuring the oxidation-reduction potential and manually inputting itpHValue comes
count
4Standard configuration
1、 SD 300pH
①Order number:724600
②Configuration: Excluding electrodes, including host, battery, protective cover, instruction manual, etc
2SD 300 pH(SET 1)
①order No 724610
②Configuration: Host, BatterypH/tempPlastic electrode(type230)ThepHBuffer set(pH 4.00/7.00/10.00)Carrying case, instruction manual.
5TECHNICAL INDEX
(1) Measurement range
pH - 2.000 ... 16.000 pH
Redox /mV - 2000.0 ... 2000.0 mV
Temperature - 5.0 ... + 150.0 °C/+ 23.0 ... + 302.0 °F
rH 0.0 ... 70.0 rH
(2) Accuracy
pH ± 0.005 pH
Redox / mV ± 0.05 % FS (mV or mVH)
Temperature ± 0.2 °C(5.0 ... + 100.0 °C)
rH ± 0.1 rH
(3) , Connect
pH,Redox BNCinterface
TemperatureBanana socket(4mm)2individual(Pt1000 or NTC 10K)
Interface / 4Extreme serial interface (optional)USB300)
(4) ThepH Calibration
1、 automatic1、2、3Point calibration is optional, useLovibondStandard buffer solution or compliantDIN19266Standard buffer solution
2、 hand movement 1、2、3Point calibration
3、 caseIP67(Outer cover and connection)
4、 Size:160×86×37mm(H×W×D)
5、 Weight:250g
6、 a housing:PA6GB30Impact resistant outer cover
7、 Packaging: shockproof packaging
8、 Power Supply:2 jointAAAbattery
9、 Battery duration:1000hour